background image

Leadership enterprise server with significantly lower cost of ownership in a highly available and 
expandable, rack-dense, 2U dual-socket server

 

Please see the Legal Information section for important notices and information. 

20 

 

Integrated Management Module

 (IMM): 

 

IPMI 2.0

 compliance, including highly secure remote power control 

 

Text console redirection

 systems management standard 

 

Active Memory protection: 

 

Advanced 

Chipkill

 ECC memory protection support  

 

Memory mirroring

 

  Integrated 

ServeRAID 

controller —

 

enhances system availability and serviceability without using 

a PCIe slot 

  A combination of 

hot-swap SAS/SATA 

HDDs

 

and

 SSDs

, or

 simple-swap SSDs

—for quicker 

servicing than with fixed drives 

 

Solid-state drives 

as a high-reliability alternative to internal storage (with up to three times the 

MTBF of spinning disk drives) 

 

Ultra-efficient cooling

 incorporating 

Calibrated Vectored Cooling 

features and 

hot-

swap/redundant fan modules 

  Standard or optional

 hot-swap/redundant power supplies

 (model-specific)

 

 

Light path diagnostics

 (front LED panel, pop-out/drop-down light path panel) 

  Optional 

Virtual Media Key

 daughter card (no slot required) 

 

Supports 

LDAP

 and 

SSL

 industry standards 

 

Toolless chassis

 and 

toolless slide

 design; integrated 

Cable Management Arm

 

 

 

Server Comparison Chart

 

The following table shows the suggested uses for the respective IBM System x rack-optimized servers, including comparisons of the 
uses for which each server is best suited: 

Important

Nice to Have

Can do without

1

2

3

Best

Better

Good

Theme

Key Workloads

S

c

a

la

b

ilit

y

F

lo

a

tin

g

 P

o

in

P

e

rfo

rm

a

n

c

e

M

e

m

o

ry

 

T

h

ro

u

g

h

p

u

t

In

te

g

e

P

e

rfo

rm

a

n

c

e

I/O

 a

n

d

 S

to

ra

g

e

D

e

n

s

ity

H

ig

h

 A

v

a

ila

b

ilit

y

S

y

st

e

m

s

 

M

a

n

a

g

e

m

e

n

t

S

e

c

u

rit

y

D

is

tri

b

u

te

d

 

D

e

p

lo

y

m

e

n

t

x

3

2

5

0

   

   

   

   

M

3

x

3

5

5

0

   

   

   

   

M

3

x

3

6

5

0

   

   

   

  

M

3

x

3

6

9

0

   

   

   

  

X

5

x

3

7

5

5

x

3

8

5

0

   

   

   

   

X

5

x

3

9

5

0

   

   

   

   

  

X

5

Cluster / HPC

3

1

1

2

2

1

3

3

3

3

Modeling & Simulation

2

1

1

1

3

1

3

2

3

3

High Performance DB

2

2

1

1

1

3

2

2

3

3

Business Intelligence

2

1

1

1

2

1

2

2

1

3

Search

3

1

1

1

2

1

3

3

1

2

Content

2

2

2

2

2

1

3

3

2

2

Communities

1

2

2

2

1

1

2

3

2

2

Commerce

2

1

1

1

2

1

1

2

1

2

Collaboration

2

3

2

3

2

1

2

3

2

2

ERP/SCM

1

2

1

1

1

2

1

1

1

2

CRM

2

2

2

2

2

2

2

2

1

3

Hosted Client

1

3

2

1

2

2

1

1

2

2

Point of Sale

3

3

3

2

1

3

1

1

1

1

Branch Office

2

3

3

3

2

2

1

1

2

1

Virtualization

1

2

2

2

1

2

1

1

2

3

Business Continuity

2

3

3

3

1

2

2

1

2

2

Database

2

2

1

2

1

2

1

2

2

3

Email/Collaboration

2

3

2

1

2

2

1

1

2

2

Security

2

2

2

2

2

1

1

1

1

3

Web Serving

3

2

2

2

3

1

2

1

3

3

File & Print

2

3

2

3

1

2

2

1

3

3

Rack-Optimized Servers

Requirements

Infrastructure 

Applications

Web 2.0 /

Web 3D

HPC

Business 

Applications

Summary of Contents for 7945D2U

Page 1: ...3MHz DDR3 memory or up to 12 DIMMs 48GB of UDIMM memory and provides Chipkill ECC Error Checking and Correcting protection for high performance and reliability For even higher levels of availability t...

Page 2: ...vers using the L5640 E5645 E5649 and 1333MHz X56xx processors support 2 DIMMs per channel 2DPC at 1333MHz running at 1 5V Optional 50GB solid state drives SSDs use only 2W of power per drive vs 9 10W...

Page 3: ...werful systems management features simplify local and remote management of the x3650 M3 The x3650 M3 includes an Integrated Management Module IMM to monitor server availability perform Predictive Fail...

Page 4: ...rt Serial over LAN enhanced authentication and encryption algorithms RMCP and AES and a firmware firewall Altitude and temperature controlled fans adjust to compensate for changing thermal characteris...

Page 5: ...I is capable of 6 4 5 86 or 4 8 GTps gigatransfers per second depending on the processor model Four core Xeon processors contain four complete processor cores 6 core processors similarly contain six c...

Page 6: ...ssors with memory The 1333MHz E56xx L5640 and X56xx processor models support up to 1333MHz memory clock speed and 2 DIMMs per channel 2DPC at 1333MHz with single rank and dual rank RDIMMs and UDIMMs r...

Page 7: ...mirroring enabled Note Due to the double writes to memory performance is affected Because the third channel is disabled with mirroring active there is no point in populating it with memory Mirroring...

Page 8: ...ts and one 5 25 inch bay for an optional DVD RW drive The bays support a combination of SATA and SAS HDDs as well as solid state drives SSDs Optionally a Tape Enablement Kit can be installed to suppor...

Page 9: ...f length One x8 low profile There is also a dedicated riser card in the x3650 M3 that provides a x8 PCIe connector wired with x4 lanes for an internal ServeRAID card Dual Port Gigabit Ethernet Control...

Page 10: ...as Calibrated Vectored Cooling The base server with one power supply includes 3 hot swap fan modules for redundant cooling Each module includes 2 back to back fans with counter rotating blades In add...

Page 11: ...ols and many components can be removed and replaced without tools including the CD RW DVD combo drive hot swap drives and PCIe adapters as well as the integrated ServeRAID card embedded hypervisor key...

Page 12: ...services to provide the level of expertise you require IBM Maintenance and Technical Support solutions can help you get the most out of your IT investment by reducing support costs increasing availabi...

Page 13: ...timer is not reset within five minutes it automatically triggers the ASR hardware which immediately restarts the server and logs an ASR event with IBM Systems Director These features are designed so t...

Page 14: ...l management capability is needed In those situations the Virtual Media Key not only offers powerful new features it does so without taking up a valuable PCI X or PCIe adapter slot instead using a ded...

Page 15: ...Slots Processor Socket ServeRAID Controller Gb Ethernet Adapter Slots Adapter Slots Processor Heat Sink Empty Hot Swap 2 5 HDD Bays Status Lights Pop Out Drop Down Light Path Diagnostics Panel Optical...

Page 16: ...4x J6x JCx 1 2 all other models Hyper Threading Technology supported Yes 2 threads per core 52x 54x 62x 72x 82x D4x H4x J4x J6x JCx L4x No 2x 22x 32x Turbo Boost Technology supported Yes 52x 54x 62x 7...

Page 17: ...y Hot swap SAS SATA also hot swap or simple swap SSD Integrated disk controller LSI 1068 of disk drives supported per port 1 Integrated RAID controller standard ServeRAID BR10il v2 no cache RAID 0 1 1...

Page 18: ...ply type AC or DC universal autoswitching hot swap Power supply standard 460W 12x 22x 32x 52x 62x D4x H4x 80 Plus Gold up to 92 efficient 675W J4x L4x 675W high efficiency 72x 82x 54x J6x JCx Up to 95...

Page 19: ...eplaceable with two x16 PCIe or two PCI X 133 slots Flexibility Large memory capacity Up to 192GB of registered DDR3 DIMMs in 18 DIMM slots Up to 16 2 5 inch hot swap SAS SATA HDDs or SSDs or simple s...

Page 20: ...ss chassis and toolless slide design integrated Cable Management Arm Server Comparison Chart The following table shows the suggested uses for the respective IBM System x rack optimized servers includi...

Page 21: ...he Windows logo are trademarks or registered trademarks of Microsoft Corporation Other company product and service names may be trademarks or service marks of others IBM reserves the right to change s...

Reviews: