Table 2. Console unit dimensions and weight (continued)
Width
434 mm (17 in.) (main chassis only, slide-rails not
included, faceplate not included)
Depth
434 mm (17 in.) (chassis behind EIA mounting
flange, bezel in front of EIA flange not included,
cable-management arm not included)
Bezel depth
35 mm (1.4 in.) (including latches and IBM Logo)
Bezel width
482 mm (19 in.) (includes latches)
Maximum forward extension
650 mm (25.6 in.)
Weight
10.4 kg (23 lb)
Installing the 7316-TF4 18.5-Inch Flat Panel Rack-Mounted Monitor and
Keyboard
This topic collection provides the information to install the 7316-TF4 18.5-Inch Flat Panel Rack-Mounted
Monitor and Keyboard console.
The console unit occupies 1U of mounting space in a rack. To install the console unit in the rack, complete
the steps in the following sections. Removing the rack doors and side panels, and removing the rack
devices that are above and below where you want to install the console unit, might make installation
easier.
See the documentation that comes with your rack for additional information.
Guidelines for rack mounting the console unit:
• Elevated operating ambient - If installed in a closed or multi-unit rack assembly, the operating ambient
temperature of the rack environment might be greater than room ambient. Therefore, consideration
should be given to installing the equipment in an environment compatible with the maximum ambient
temperature (Tma) specified by the manufacturer.
• Reduced air flow - Installation of the equipment in a rack should be such that the amount of air flow
required for safe operation of the equipment is not compromised.
• Mechanical loading - Mounting of the equipment in the rack should be such that a hazardous condition
is not achieved due to uneven mechanical loading.
• Circuit overloading - Consideration should be given to the connection of the equipment to the supply
circuit and the effect that overloading of the circuits might have on overcurrent protection and supply
wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this
concern.
• Reliable earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular
attention should be given to supply connections other than direct connections to the branch circuit (for
example, use of power strips).
CAUTION: This product is equipped with a 3-wire (two conductors and ground) power cable and
plug. Use this power cable with a properly grounded electrical outlet to avoid electrical shock.
C018
Installing the keyboard in the console unit
Learn how to install the keyboard in the console unit.
To install the keyboard in the console unit, complete the following steps:
1. Place the console unit on a table or other flat surface and make sure that the right side of the unit
extends approximately 76 mm (3 in.) over the edge of the surface. This will help you route the
keyboard-and-mouse cable more easily later in the procedure.
4 Power Systems: Installing the 7316-TF4 18.5-Inch and 7316-TF5 17.3-Inch Flat Panel Rack-Mounted
Monitor and Keyboard