3.
Insert
the
firmware
update
diskette
or
CD
into
the
CD
or
DVD
drive.
4.
Turn
on
or
restart
the
server.
The
server
starts
DOS
from
the
diskette
or
CD
and
runs
the
necessary
utilities.
5.
If
prompted
with
questions,
type
Y
and
press
Enter.
Using
the
force
BMC
update
jumper
If
the
normal
firmware
update
procedure
results
in
an
inoperative
BMC,
change
the
position
of
the
force
BMC
update
jumper
(J57
on
the
microprocessor
board)
to
bypass
the
operational
firmware
image.
Attention:
Before
changing
any
switch
settings
or
moving
any
jumpers,
turn
off
the
server;
then,
disconnect
all
power
cords
and
external
cables.
See
the
safety
information
beginning
on
page
v.
Do
not
change
settings
or
move
jumpers
on
any
system-board
switch
or
jumper
blocks
that
are
not
shown
in
this
document.
The
following
illustration
shows
the
location
of
the
force
BMC
update,
and
boot
recovery
jumpers.
Boot recovery (J17)
Force BMC
update
(J57)
1
2
3
4
1 2
1
2
3
While
the
server
is
turned
off,
place
a
jumper
over
pins
1
and
2
on
J57.
Then,
perform
a
firmware
update.
Turn
off
the
server
again
and
remove
the
jumper
from
pins
1
and
2.
Note:
Only
use
the
force
BMC
update
jumper
if
the
normal
firmware
update
procedure
fails
and
the
operational
firmware
image
is
corrupted.
Use
of
the
force
BMC
update
jumper
disables
normal
baseboard
management
controller
operation.
Using
the
management
utility
program
Use
the
baseboard
management
controller
management
utility
program
to
remotely
manage
and
configure
a
server.
The
following
features
are
available
from
the
program:
66
IBM
System
x3850
M2
and
System
x3950
M2
Type
7141:
User’s
Guide
Summary of Contents for 72335LU - System x3850 M2
Page 1: ...IBM System x3850 M2 and System x3950 M2 Type 7141 User s Guide ...
Page 2: ......
Page 3: ...IBM System x3850 M2 and System x3950 M2 Type 7141 User s Guide ...
Page 82: ...70 IBM System x3850 M2 and System x3950 M2 Type 7141 User s Guide ...
Page 84: ...72 IBM System x3850 M2 and System x3950 M2 Type 7141 User s Guide ...
Page 90: ...78 IBM System x3850 M2 and System x3950 M2 Type 7141 User s Guide ...
Page 94: ...82 IBM System x3850 M2 and System x3950 M2 Type 7141 User s Guide ...
Page 95: ......
Page 96: ... Part Number 40M2362 Printed in USA 1P P N 40M2362 ...