background image

Page 32 of 47

USING THE JPEG IMAGE VIEWER

The JPEG Image Viewer provides a method of viewing compressed JPEG files.  You can use the
Image Viewer to open JPEG files produced by digital cameras or down loaded from an online
service.

To start the Image Viewer:

NAVIGATE: From the Multimedia Modem go to Image Viewer.

To open JPEG files and view them in the JPEG Image Viewer Window:

1.

 

Click on the File drop down menu.

2.

 

Select OPEN or PHOTOGRAPH.

3.

 

Use Browse to locate the JPEG file.

4.

 

Click on OK.

NOTES:

1.

 

The JPEG Image Viewer requires at least a 256-color palette to display images.  It will check
your display mode to determine if the computer has the correct hardware and is in a correct
mode.  The Image View application will not start if your computer is not in the 256 or higher
color mode.

2.

 

Supports only interlaced JPEG files.

3.

 

Not available to OS/2 users.

Summary of Contents for 715 P/N - 13H6715

Page 1: ...N 13H6715 FIRST EDITION DECEMBER 1995 C COPYRIGHT INTERNATIONAL BUSINESS MACHINES CORPORATION 1995 ALL RIGHTS RESERVED Note to U S Government Users Documentation related to restricted rights Use dupli...

Page 2: ...NSTALLING APPLICATIONS SOFTWARE 19 UNINSTALLING MULTIMEDIA MODEM PLUS SOFTWARE 19 USING VOICE FAX AND DATA 21 MANUAL DISCRIMINATION 21 SETTING MWAVE DISCRIMINATOR OPTIONS 22 CALLER ID IDENTIFICATION 2...

Page 3: ...CONNECTIONS 41 SUPPORTED INTERNAL CD ROM DRIVES 41 EXTERNAL I O CONNECTIONS 41 POWER REQUIREMENTS 42 FAX MODEM 42 DATA MODEM 42 TELEPHONY SUBSYSTEM 42 AUDIO FEATURES 43 IBM MULTIMEDIA MODEM PLUS SETTI...

Page 4: ...eration of your computer NAVIGATION Identifies instructions on how to get to the function that is described WARNING A word for calling attention to the possibility of damage to a program device or sys...

Page 5: ...r clear two way conversation while you work JPEG image viewer for viewing JPEG compressed image files JPG BEFORE YOU BEGIN You might need information about the current system board settings and settin...

Page 6: ...rive 6 MB of memory 8 MB of memory is recommended 17 MB of available hard disk space Windows 3 1 or 3 11 running in 386 enhanced mode under DOS 5 0 or higher OR Windows 95 OR OS 2 Warp with Multimedia...

Page 7: ...er Microsoft Windows 3 1 or 3 11 under DOS 5 0 or higher Microsoft Windows 95 OS 2 Warp with Windows or WIN OS 2 installed NOTE During the installation process some message windows boxes may appear wh...

Page 8: ...lect MY COMPUTER click on the A drive object and select SETUP from the list of programs and then start the Setup program Continue with 4 2 To start the setup program type A SETUP Click on OK or press...

Page 9: ...ram 7 When the MIDI EMU Wave Samples prompt is displayed insert EMU Disk 1 and click on OK 8 When you are prompted for the name of the MIDI samples directory click on OK to install them in the default...

Page 10: ...d click on YES In Windows 3 x exit Windows 2 At the DOS prompt change to directory C DSP2 SOLO If you did not install the Mwave software in C DSP2 SOLO change to the appropriate directory 3 At the dir...

Page 11: ...media Modem Plus However if a conflict is found or you are using the CD ROM controller interface you must manually change the appropriate configuration settings NOTE Use this procedure to change setti...

Page 12: ...change the DOS parameters for your session 1 Exit Windows and start your computer in DOS 2 From any directory type FASTCFG and press Enter 3 When the Fastcfg Current Mwave DOS Settings window is displ...

Page 13: ...Setup program takes some time to initialize NOTE If you had a Multimedia Modem previously installed in your computer you are asked if you want to continue and overwrite the previous installation Clic...

Page 14: ...of the MIDI Samples directory click on OK to install them in the default directory or type another directory name and click on OK 10 If you are asked if you want your OS 2 Mwave synthesizer to use th...

Page 15: ...lled you might have to change the default settings If you connected a CD ROM to your modem you need to change the CD ROM TYPE and BASE I O ADDRESS fields If a CD ROM base I O address is part of your C...

Page 16: ...dentifier conflict check your computer manual to determine if you have an unused COM port and IRQ identifier pair After resolving the conflict run SETUP again to change the settings NOTE If an IRQ ass...

Page 17: ...en the IBM Multimedia Presentation Manager 2 Installation window is displayed IBM MWAVE AUDIO should be highlighted Click on INSTALL to start the installation program 5 When you are asked if you want...

Page 18: ...2 is normally the right mouse button b Click on Settings c Select the Sessions Tab d Select WIN OS 2 Settings e Select all DOS and WIN OS 2 Settings and click on OK f Select WIN_RUN_MODE g A window i...

Page 19: ...UNINSTALLING MULTIMEDIA MODEM PLUS SOFTWARE If you ever remove the Multimedia Modem Plus adapter from your computer you must use the uninstall process to be sure that the Mwave software is removed fro...

Page 20: ...rompt type A SETUP and press ENTER The Setup program takes some time to initialize 4 Select the uninstall option if you want to remove the Multimedia Modem software from your computer IMPORTANT If you...

Page 21: ...s and an On Line Terminal Application for data modem messages You can specify the types of call that QuickLink Message Center should handle If you want to use a different voice fax or data program you...

Page 22: ...riminator Window at all times select OPTIONS in the Mwave Discriminator Window and click on ALWAYS ON TOP CALLER ID IDENTIFICATION The discriminator can route a call directly to the application for a...

Page 23: ...Mwave Discriminator then knows to route this call to the fax application For you to complete this set up you must also record the same codes in in the Select DTMF Codes Window NAVIGATE From the Mwave...

Page 24: ...tion program may start the message with silence to indicate a fax or data message Set up discriminator messages You can edit three not available messages and one initial greeting message using the mes...

Page 25: ...carry on a conversation and share data with another person at the same time over one telephone line The IBM Multimedia Modem Plus provides a voice over data function with the caller s computer system...

Page 26: ...1V1X4 C1 D2 E1 USING THE MWAVE MODEM The IBM Multimedia Modem Plus allows you to view the modem s operational state You may also need this information to help diagnose modem communication problems NAV...

Page 27: ...unctions of the IBM Multimedia Modem Plus SETTING WINDOWS AUDIO CONTROLS You can control all of the IBM Multimedia Modem Plus audio controls for Windows and WIN OS 2 from the Mwave Audio Mixer Window...

Page 28: ...e INPUT SOURCE GAMES WAVE and MIDI For the audio output signal you control the combined signals from all the inputs using the MASTER control To control the volume and balance on the Mwave Audio Mixer...

Page 29: ...IO CONTROLS You use the Mwave Auxiliary Control Window to control the input source for OS 2 CD ROM line and microphone applications This function replaces the Mwave Audio Mixer since it is not availab...

Page 30: ...drivers to the system see the documentation that comes with your computer USING DOS APPLICATIONS USING THE FASTCFG SCREEN IBM Multimedia Modem Plus has the features of both a sound card and a modem t...

Page 31: ...IRQ These settings must not conflict with other active serial ports in your system Consult your computer documentation for the method to view and change your configuration if required 2 If you alread...

Page 32: ...es and view them in the JPEG Image Viewer Window 1 Click on the File drop down menu 2 Select OPEN or PHOTOGRAPH 3 Use Browse to locate the JPEG file 4 Click on OK NOTES 1 The JPEG Image Viewer require...

Page 33: ...COM Port conflict detected but no other device is using the port SOLUTION Your operating system is using the specified COM Port See your computer operations manual for instructions on disabling the po...

Page 34: ...hoose a different DMA channel setting for the Multimedia Modem Plus adapter OPERATION PROBLEMS Use this section to solve operational problems PROBLEM Need a test method for the modem function CAUSES S...

Page 35: ...setting for the COM Port to match the IRQ setting listed in the configuration program PROBLEM Can not receive or send a fax in a Windows application CAUSES SOLUTION If the CONFIG EXE tests passed the...

Page 36: ...e your configuration choices do not conflict with values already used by the system Also try typing MSD at the DOS command line If the MSD EXE is available on your system it will provide you with valu...

Page 37: ...e you may receive the following error message when the Multimedia Modem Plus board is installed and the system attempts to load the mouse driver during the boot sequence Interrupt jumper missing Use o...

Page 38: ...or the location of the following statement DEVICE C DSP2 SOLO MWDDSOLO EXE Make sure this statement appears above the CD ROM driver statements in CONFIG SYS If it does not use an editor to move the li...

Page 39: ...may have a configuration conflict Run CONFIGO again and choose different settings that do not conflict with the other hardware settings in your system See your system documentation for details If you...

Page 40: ...on if you plan to install Multimedia Modem Plus under OS 2 Warp and Windows in the same computer AUDIO APPLICATIONS 1 If a loud squealing noise comes from the speakers there is audio feedback coupling...

Page 41: ...AA for telephony UART 16550 emulation for modem and fax operation Jumperless installation manager Three way discrimination between incoming fax voice and data calls INTERNAL I O CONNECTIONS Panasonic...

Page 42: ...data modem DSVD support when connected to another IBM Mwave modem Hayes AT Command Set compatibility V 42 bis MNP 5 data compression V 42 MNP 1 4 error correction TELEPHONY SUBSYSTEM Transmit receive...

Page 43: ...reo sampling rates up to 44 100 Hz Dynamic range 16 bit stereo S N D Ratio LL I O 80 dB S N D Ratio Mic in 48 dB Mic In signal level 0 2 V rms ext Mic In input impedance 2 kohm ext Output level max at...

Page 44: ...MPRESSION The process of eliminating gaps empty fields redundancies and unnecessary data to shorten the length of records or blocks DAA Data access arrangement DSP Digital signal processor DMA Direct...

Page 45: ...ures Experts Group SYNCHRONOUS Pertaining to two or more processes that depend upon the occurrence of specific events such as common timing signals TAPI Telephony application programming interface WIN...

Page 46: ...duct program or service is not intended to state or imply that only that IBM product program or service may be used Subject to IBM s valid intellectual property or other legally protectable rights any...

Page 47: ...icrocom Microcom Systems Inc Microsoft Microsoft Corporation MNP Microcom Systems Inc DOS Microsoft Corporation FaxWorks SofNet Inc Norton Antivirus Symantec Corporation Panasonic Matsushita Electric...

Reviews: