Figure 18. Replace fascia components on the disk enclosure
Installing or replacing a drive
Use the following procedure to install a drive for the first time or to replace a faulty drive in a 5U92 disk
enclosure with a new one received from FRU stock.
Before you begin
Important:
• You can replace a drive assembly without powering off the disk enclosure. However, to maintain
operating temperature, do not keep the cover off an operational enclosure for more than 15 minutes.
The reduction in airflow through the enclosure might cause the enclosure or its components to shut
down to protect from overheating.
• Ensure that the drive that you are replacing is not a spare or a member of an array. The drive status is
shown in Pools > Internal Storage in the management GUI. If the drive is a member of an array, follow
the fix procedures in the management GUI. The fix procedures minimize the risk of losing data or access
to data; the procedures also manage the system's use of the drive.
About this task
The 5U92 disk enclosure supports 92 drives. Figure 19 on page 25 shows an example of a drive
assembly.
Figure 19. Drive assembly
1
Disk drive
2
Online indicator
3
Fault indicator
4
Release latch
5
Drive latch toes
Chapter 2. Installing the system hardware 25
Summary of Contents for 5U92
Page 1: ...IBM Cloud Object Storage System Version 3 15 6 J15 Appliance Manual IBM...
Page 10: ...x...
Page 12: ...xii...
Page 24: ...xxiv IBM Cloud Object Storage System Version 3 15 6 J15 Appliance Manual...
Page 32: ...4 IBM Cloud Object Storage System Version 3 15 6 J15 Appliance Manual...
Page 140: ...112 IBM Cloud Object Storage System Version 3 15 6 J15 Appliance Manual...
Page 141: ......