12 IBM 4769 Installation
Temperature
Do not expose the coprocessor to temperatures outside the limits in
Batteries
Do not remove battery power from the coprocessor. Data in the protected memory is lost
(zeroized) when battery power is removed, rendering the coprocessor permanently inoperable.
For information about replacing the batteries without erasing the protected memory, see
“Replacing coprocessor batteries” on page 7.
Requirements and specifications
The requirements and specification for the coprocessor consist of the necessary hardware and
software, environmental requirements, and physical characteristics.
Hardware requirement
The coprocessor must be installed in an x86 server from the list of x86 servers. See notes
below. No additional hardware or cabling is required.
Note:
The full speed USB 2.0 Micro connector is for development use only. It is not intended for
customer use.
Software requirement
The coprocessor requires support software, for example, the IBM 4769 CCA Support Program,
for both the host machine and for its internal firmware. Operating system support is determined
by the support software. This publication does not discuss the installation of support software.
For information about the latest software features available, visit the
Power requirements
The power requirements for the IBM 4769-001 PCIe Cryptographic Coprocessor are:
•
+12-volt PCIe domain: 20.13 watts maximum
•
+3.3-volt PCIe domain: 3.31 watts maximum (including USB external load)
•
On-board batteries: batteries dead less than 2.0 volts; low-battery warning less than 2.75
volts
Environmental specifications
The environmental specifications for the IBM 4769-001 PCIe Cryptographic Coprocessor are
shown in Table 1.
Table 1 Operating, storage, and shipping environmental specifications
Operating
environment
Storage
environment
Shipping
environment
Temperature
+5°C to +40°C
(+41°F to +104°F)
+1°C to +60°C
(+33.8°F to +140°F)
-34°C to +60°C
(-29.2°F to +140°F)
Relative humidity
8 to 85%
5 to 80%
5 to 100%
Wet bulb
< +24.0°C (+75°F)
< +29.0°C (+84.2°F)
< +29.0°C (+84.2°F)
Pressure (minimum)
550 mbar (maximum
altitude 16 400 ft)
550 mbar (maximum
altitude 16 400 ft)
550 mbar (maximum