background image

IBM 4033/Lexmark MarkNet

OSR

 

Models 2XX, 3XX:

The Status LED blinks to indicate an error was detected after a successful Reset.
The Test and Data LEDs indicate what type of error was detected:

Note:  If you are updating the flash code, the Status, Test, and Data LEDs will all
blink. This does not indicate an error.

Sample Print Test (Models 20X and 30X)

Press and release the Test button to send a single-page file to all ports. If the test is
successful, go to “LAN Connection Check.” If the print test fails, go to “Wrap Test
for Adapter Ports.”

Wrap Test for Adapter Ports

To test any port:

1.

Disconnect the printer cable from the adapter.

2.

Install a wrap plug on that port.

  3.

Press Reset.

 Models 0XX:

The Status LED will blink several times within 3 to 4 seconds, turn off for up to 10
seconds, then blink continuously in a pattern of two blinks, a pause, then two blinks.
Any other pattern on blinks indicates a failure of the Replace the adapter if the test
fails.

Models 20X and 30X:

A successful test results in only the Power and Status LEDs on, just like a normal
Reset. Replace the adapter if the test fails.

LAN Connection Check

1.

For Token-Ring using shielded twisted-pair cable (Models 001, 011, 201,
or 301): Disconnect the LAN cable from the network, leaving it connected to
the adapter.

For Ethernet 10Base2 (Models 003, 013, 202, or 302): Make sure the switch
is set to position 2 for Models 003 and 013, or position 16/2 for Models 202
and 302. Attach a 50 ohm BNC terminator cap to each end of the T-connect
or. (The customer may be able to supply these caps.)

For Token-Ring using unshielded twisted-pair cable (Models 201 or 301 )
or Ethernet 1 10BaseT (Models 002, 012, 202, or 302): There is no LAN con-
nection test for these configurations. Refer to “Printer and LAN checks.”

2.

Press the Reset button.

Models 0XX:

The status LED will blink several times within 3-4 seconds, turn off for up to
30 seconds, then turn on solid.

Models 20X and 30X:

The adapter will go through a reset cycle and stop with on the Power and
Status LEDs on.

Any other result indicates a failure of the test. For Token-Ring using shielded
twisted-pair cable, verify the continuity of the cable and replace the adapter if
the cable is good. For Ethernet 1 10Base2 replace the adapter.

Printer and LAN checks

 Reset Cycle

If the adapter checks out successfully, the problem may be with other hardware or
software on the network. The following
 are suggestions to the customer for checking hardware and software for possible
problems.

 Printer checks

Make sure the printer is operating correctly by running printer diagnostics and

the printer wrap test.

Make sure the printer is configured for the right type of port (parallel or serial).

Make sure the jumper and power cords are properly connected.

Make sure the printer is queued and the printer driver is configured properly.

Make sure the proper adapter port has been associated (parallel or serial).

Make sure the adapter's printer port parameters match those of the printer (for

example, parallel mode, serial baud rate, and serial protocol).

 LAN checks

Make sure the software utility has been correctly installed.

Make sure the LAN cable and LAN connections are good.

Make sure a single route broadcast is supported across the network bridges, if a

bridge is used.

Make sure the server is working properly. Review print server installation and

configuration using the appropriate system guide to operation.

 Parts Catalog

2XX, 3XX Models

 0XX Models

0XX Models (Continued)

Status

Test

Data

Error

Action

blink

off

off

software

Contact next
level of
support.

blink

off

on

network

Refer to
Printer and
LAN Checks.

P/N

Description

1381605

4033- 201 Token-Ring network adapter

1381603

4033- 202 Ethernet network adapter

1381606

4033- 301 Token-Ring network adapter with serial port

1381604

4033- 302 Ethernet network adapter with serial port

1418613

Cover, switch

1418601

Cord set, jumper power

2182994

T-connector, Ethernet

Status

Test

Data

Failure

9900769

Wrap plug, parallel

off

off

blink

Parallel 1 port wrap failure

9900770

Wrap plug, serial

off

blink

off

Parallel 2 port wrap failure

72X8546

Wrap plug, multifunction

off

blink

blink

Serial port wrap failure

P/N

Description

1333658

Adapter Asm., Model 4033-001 (no P/S)

1333588

Adapter Asm., Model 4033-002 (no P/S)

1333589

Adapter Asm., Model 4033-003 (no P/S)

1333787

Adapter Asm., Model 4033-011 (no P/S)

1333788

Adapter Asm., Model 4033-012 (no P/S)

1333789

Adapter Asm., Model 4033-013 (no P/S)

1333586

Operator Panel Board, 4033-001, 4033-011,

1333595

Operator Panel Board, 4033-002, 4033-003, 4033-012,
4033-013

1333590

Power Supply, US Model 4033-001, 4033-002, 4033-011,
4033-012

1333591

Power Supply, US Model 4033-003, 4033-013, WT (except
Nordic)

1333592

Power Supply, Nordic

P/N

Description

72X8546

Wrap Plug, multi-function

71F1168

Terminator Cap, 25 Ohm, BNC

1339517

Line Cord, US, Canada, Columbia, Saudi Arabia

6185888

Line Cord, US, 6 ft.

1339520

Line Cord, Europe

Test

Power

Status

Test

Data

1339523

Line Cord, South Africa

1

on

off

off

off

1339522

Line Cord, Switzerland

2

on

on

on

on

1339524

Line Cord, Italy

3

on

off

on

on

1339525

Line Cord, Denmark

4

on

off

on

off

1339518

Line Cord, New Zealand/Australia, Argentina, Uruguay

5

on

off

off

on

1339521

Line Cord, Israel

6

on

off

off

off

1339519

Line Cord, UK

End

on

on

off

off

1339523

Line Cord, Pakistan

1339519

Line Cord, Hong Kong, Malaysia, Singapore, Burma, Brunei,
India

1339523

Line Cord, Bangladesh, Sri Lanka

2

LM-4

IBM/TSS Internal Use Only

Reviews: