IBM 4033/Lexmark MarkNet
OSR
Models 2XX, 3XX:
The Status LED blinks to indicate an error was detected after a successful Reset.
The Test and Data LEDs indicate what type of error was detected:
Note: If you are updating the flash code, the Status, Test, and Data LEDs will all
blink. This does not indicate an error.
Sample Print Test (Models 20X and 30X)
Press and release the Test button to send a single-page file to all ports. If the test is
successful, go to “LAN Connection Check.” If the print test fails, go to “Wrap Test
for Adapter Ports.”
Wrap Test for Adapter Ports
To test any port:
1.
Disconnect the printer cable from the adapter.
2.
Install a wrap plug on that port.
3.
Press Reset.
Models 0XX:
The Status LED will blink several times within 3 to 4 seconds, turn off for up to 10
seconds, then blink continuously in a pattern of two blinks, a pause, then two blinks.
Any other pattern on blinks indicates a failure of the Replace the adapter if the test
fails.
Models 20X and 30X:
A successful test results in only the Power and Status LEDs on, just like a normal
Reset. Replace the adapter if the test fails.
LAN Connection Check
1.
For Token-Ring using shielded twisted-pair cable (Models 001, 011, 201,
or 301): Disconnect the LAN cable from the network, leaving it connected to
the adapter.
For Ethernet 10Base2 (Models 003, 013, 202, or 302): Make sure the switch
is set to position 2 for Models 003 and 013, or position 16/2 for Models 202
and 302. Attach a 50 ohm BNC terminator cap to each end of the T-connect
or. (The customer may be able to supply these caps.)
For Token-Ring using unshielded twisted-pair cable (Models 201 or 301 )
or Ethernet 1 10BaseT (Models 002, 012, 202, or 302): There is no LAN con-
nection test for these configurations. Refer to “Printer and LAN checks.”
2.
Press the Reset button.
Models 0XX:
The status LED will blink several times within 3-4 seconds, turn off for up to
30 seconds, then turn on solid.
Models 20X and 30X:
The adapter will go through a reset cycle and stop with on the Power and
Status LEDs on.
Any other result indicates a failure of the test. For Token-Ring using shielded
twisted-pair cable, verify the continuity of the cable and replace the adapter if
the cable is good. For Ethernet 1 10Base2 replace the adapter.
Printer and LAN checks
Reset Cycle
If the adapter checks out successfully, the problem may be with other hardware or
software on the network. The following
are suggestions to the customer for checking hardware and software for possible
problems.
Printer checks
Make sure the printer is operating correctly by running printer diagnostics and
the printer wrap test.
Make sure the printer is configured for the right type of port (parallel or serial).
Make sure the jumper and power cords are properly connected.
Make sure the printer is queued and the printer driver is configured properly.
Make sure the proper adapter port has been associated (parallel or serial).
Make sure the adapter's printer port parameters match those of the printer (for
example, parallel mode, serial baud rate, and serial protocol).
LAN checks
Make sure the software utility has been correctly installed.
Make sure the LAN cable and LAN connections are good.
Make sure a single route broadcast is supported across the network bridges, if a
bridge is used.
Make sure the server is working properly. Review print server installation and
configuration using the appropriate system guide to operation.
Parts Catalog
2XX, 3XX Models
0XX Models
0XX Models (Continued)
Status
Test
Data
Error
Action
blink
off
off
software
Contact next
level of
support.
blink
off
on
network
Refer to
Printer and
LAN Checks.
P/N
Description
1381605
4033- 201 Token-Ring network adapter
1381603
4033- 202 Ethernet network adapter
1381606
4033- 301 Token-Ring network adapter with serial port
1381604
4033- 302 Ethernet network adapter with serial port
1418613
Cover, switch
1418601
Cord set, jumper power
2182994
T-connector, Ethernet
Status
Test
Data
Failure
9900769
Wrap plug, parallel
off
off
blink
Parallel 1 port wrap failure
9900770
Wrap plug, serial
off
blink
off
Parallel 2 port wrap failure
72X8546
Wrap plug, multifunction
off
blink
blink
Serial port wrap failure
P/N
Description
1333658
Adapter Asm., Model 4033-001 (no P/S)
1333588
Adapter Asm., Model 4033-002 (no P/S)
1333589
Adapter Asm., Model 4033-003 (no P/S)
1333787
Adapter Asm., Model 4033-011 (no P/S)
1333788
Adapter Asm., Model 4033-012 (no P/S)
1333789
Adapter Asm., Model 4033-013 (no P/S)
1333586
Operator Panel Board, 4033-001, 4033-011,
1333595
Operator Panel Board, 4033-002, 4033-003, 4033-012,
4033-013
1333590
Power Supply, US Model 4033-001, 4033-002, 4033-011,
4033-012
1333591
Power Supply, US Model 4033-003, 4033-013, WT (except
Nordic)
1333592
Power Supply, Nordic
P/N
Description
72X8546
Wrap Plug, multi-function
71F1168
Terminator Cap, 25 Ohm, BNC
1339517
Line Cord, US, Canada, Columbia, Saudi Arabia
6185888
Line Cord, US, 6 ft.
1339520
Line Cord, Europe
Test
Power
Status
Test
Data
1339523
Line Cord, South Africa
1
on
off
off
off
1339522
Line Cord, Switzerland
2
on
on
on
on
1339524
Line Cord, Italy
3
on
off
on
on
1339525
Line Cord, Denmark
4
on
off
on
off
1339518
Line Cord, New Zealand/Australia, Argentina, Uruguay
5
on
off
off
on
1339521
Line Cord, Israel
6
on
off
off
off
1339519
Line Cord, UK
End
on
on
off
off
1339523
Line Cord, Pakistan
1339519
Line Cord, Hong Kong, Malaysia, Singapore, Burma, Brunei,
India
1339523
Line Cord, Bangladesh, Sri Lanka
2
LM-4