__ 7.

Find the package that contains the new adapter card.

Attention:

Adapter cards are fragile:

v

Handle only by the edges

v

Keep fingers off printed circuit area

v

Use static strap when handling

v

Leave in protective packaging until ready to install

Remove the adapter card from the electrostatic package.

__ 8.

Install the adapter card in the Expansion unit side of the system unit by
doing the following:

a.

Align the adapter card with the card slot

E07

(Figure 6 on page 7).

b.

Slide the card into the system unit and push on both sides of the card
until the card is all the way into the slot and the connector.

Note:

The screw tab on the adapter card should be even with the frame
on the system unit and aligned with the screw hole when
completely installed.

c.

Install the screw

A

that holds the adapter card in place, (Figure 6 on

page 7).

Figure 5. Remove Slot Cover

6

AS/400e 170 or 250 2809 or 2824 LAN/WAN Workstation Card V4R5

Summary of Contents for 2809

Page 1: ...AS 400e 170 or 250 2809 or 2824 LAN WAN Workstation Card Instruction V ersion 4 SENG 2809 04 ...

Page 2: ......

Page 3: ...AS 400e 170 or 250 2809 or 2824 LAN WAN Workstation Card Instruction V ersion 4 SENG 2809 04 ...

Page 4: ...nd the Notices on page 11 Fifth Edition July 2000 This edition applies only to reduced instructions set computer RISC systems Copyright International Business Machines Corporation 1998 2000 All rights reserved US Government Users Restricted Rights Use duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp ...

Page 5: ...If possible disconnect all power cords from the existing system before you add or remove a device RSFTD203 DANGER To prevent a possible electrical shock during an electrical storm do not connect or disconnect cables or station protectors for communications lines display stations printers or telephones RSFTD003 DANGER To prevent a possible electrical shock from touching two surfaces with different ...

Page 6: ...pecific information on each battery type where applicable Battery Return Program In the United States IBM has established a collection process for reuse recycling or proper disposal of used IBM batteries and battery packs For information on proper disposal of the batteries in this unit please contact IBM at 1 800 426 4333 Please have the IBM part number that is listed on the battery available when...

Page 7: ...to perform the task are the same __ 4 Before you begin v Ensure that you have a current backup of your operating system and licensed programs If you have backed up the operating system and licensed programs since the last time you applied PTFs that backup is acceptable v Ensure that you take a few minutes to become familiar with these instructions v If there are incorrect missing or visibly damage...

Page 8: ...ring the installation contact your authorized dealer or service provider __ 3 When the AS 400 is completely powered down power off all PCs and devices such as printers and displays that are connected to the system unit __ 4 Unplug any power cords such as printers and displays from electrical outlets __ 5 Unplug the system unit power cord from the electrical outlet __ 6 Remove the system unit back ...

Page 9: ... through E14 in the expansion unit Figure 2 Slot E01 is not an available position __ 2 Remove the left side cover by removing the screws and sliding the cover from front to back until it stops Pull the cover out Figure 3 on page 4 Figure 2 Adapter Card Positions Installation Instructions 3 ...

Page 10: ...dhesive part of the foil to an unpainted surface Notes a Follow the same precautions you would use without the wrist strap The 2209 Disposable Wrist Strap is for static control It will not increase nor decrease your risk of receiving electric shock when using or working on electrical equipment b Discard the wrist strap immediately and contact your dealer for a replacement if the disposable wrist s...

Page 11: ...ard slot E07 __ 6 Before you install the adapter card remove the adapter card slot cover inside the system unit by doing the following a Remove the screw Figure 5 on page 6 b Slide the slot cover out Figure 4 Attach Wrist Strap Installation Instructions 5 ...

Page 12: ...e of the system unit by doing the following a Align the adapter card with the card slot E07 Figure 6 on page 7 b Slide the card into the system unit and push on both sides of the card until the card is all the way into the slot and the connector Note The screw tab on the adapter card should be even with the frame on the system unit and aligned with the screw hole when completely installed c Instal...

Page 13: ...u where to install the adapter card and complete the installation If you have another device such as a disk unit a tape unit or a memory card to install go to the instructions that came with that device __ 10 Install the Expansion unit side cover by aligning the tabs on the top and bottom edge and press forward to make sure that all tabs enter the slots Slide the cover toward the front of the syst...

Page 14: ...ach to the system It is the customer s responsibility to ensure that the outlet is correctly wired and grounded to prevent an electrical shock RSFTD201 Plug the following power cords into an electrical outlet v System unit v System unit console __ 3 Plug in and power on all attached devices such as printers and displays Figure 7 Install Side Cover 8 AS 400e 170 or 250 2809 or 2824 LAN WAN Workstat...

Page 15: ...y 6 to 10 minutes to power on and complete an IPL __ 7 Sign on the system unit Ensure that you have service tools authority __ 8 Do the following to verify your adapter card configuration a On an AS 400 command line type STRSST Press the Enter key b When the Start a Service Tools menu appears select the Start a service tool option Press the Enter key c When the Start a Service Tool menu appears se...

Page 16: ...inistration and Problem Handling SC41 5206 04 5 Go to step 9 __ 9 Print the configuration list if you have a printer Note To print the configuration list press F6 on the Packaging Hardware Resources menu Place the configuration list in the Basic System Operation Administration and Problem Handling SC41 5206 04 book __ 10 To return to the AS 400 Main menu press F3 three times and then press the Ent...

Page 17: ...de Asia Corporation Licensing 2 31 Roppongi 3 chome Minato ku Tokyo 106 Japan The following paragraph does not apply to the United Kingdom or any other country where such provisions are inconsistent with local law INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF ...

Page 18: ...ired to correct the interference at his own expense Properly shielded and grounded cables and connectors IBM Part Number 75G5958 75G2865 97H7385 or its equivalent must be used in order to meet FCC emission limits IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment ...

Page 19: ...s product may cause radio interference in which case the user may be required to take adequate measures Trademarks The following terms are trademarks of the IBM Corporation in the United States or other countries or both AS 400 AS 400e series Client Access Client Access 400 IBM Operating System 400 OS 400 400 800 IBM CALL Microsoft Windows Windows NT and the Windows logo are trademarks or register...

Page 20: ...14 AS 400e 170 or 250 2809 or 2824 LAN WAN Workstation Card V4R5 ...

Page 21: ...his book is Very Satisfied Satisfied Neutral Dissatisfied Very Dissatisfied Accurate h h h h h Complete h h h h h Easy to find h h h h h Easy to understand h h h h h Well organized h h h h h Applicable to your tasks h h h h h Please tell us how we can improve this book Thank you for your responses May we contact you h Yes h No When you send comments to IBM you grant IBM a nonexclusive right to use...

Page 22: ...LERK 3605 Highway 52 N ROCHESTER MN 55901 7829 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Page 23: ......

Page 24: ... Printed in the United States of America on recycled paper containing 10 recovered post consumer fiber SENG 2809 04 ...