background image

MANUAL - E-BEEDREAM100

4

Code:  16-2108

•  Always disconnect from power source before servicing or replacing fuse and be sure to replace with same fuse 

size and type.

• 

Secure fixture to fastening device using a safety chain. Never carry the fixture solely by its head. Use its carry

-

ing handles.

• 

Maximum ambient temperature (Ta) is 35°C.  Do not operate the fixture at temperatures higher than this.

• 

The surface temperature of the unit may reach up to 120°C. DO NOT TOUCH the housing barehand during its 

operation. Turn off the power and allow about 15 minutes for the unit to cool down before replacing or servic

-

ing.

• 

DO NOT OPEN the unit within 5 minutes after switching off.

• 

In the event of a serious operating problem, stop using the unit immediately. Never try to repair the unit by 

yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the near-

est authorized technical assistance center. Always use the same type of spare parts.

•  Don’t connect the device to a dimmer pack.
•  Make sure the power cord is never crimped or damaged.
•  Never disconnect the power cord by pulling or tugging on the cord.
•  Avoid direct eye exposure to the light source while it is on.
•  The product is for decorative purposes only and not suitable as a household room illumination.
• 

The light source of this luminaire is not replaceable. When it reaches the end of its life time, the whole unit 

must be discarded.

• 

DISCONNECT DEVICE

: Where the MAINS plug or an appliance coupler is used as the disconnect device, the 

disconnect device shall remain readily operable.

INSTALLATION

The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to 

avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit 

is secure and able to support a weight of 10 times of the unit’s weight. Also always use a safety cable that can 

hold 12 times the weight of the unit when installing the fixture.
Never stand directly below the device when mounting, removing or servicing the fixture. This fixture may be 

mounted in any position provided there is adequate room for ventilation.

The LED moving head provides a unique mounting bracket assembly that integrates the bottom of the base, the 

included ‘omega bracket’ and the safety cable rigging point in one unit.When mounting this fixture on a truss, be 

sure to use an appropriate clamp with the included omega bracket using a M10 screw fitted through the center 

hole of the ‘omega bracket’. As an added safety measure, be sure to attach at least one properly rated safety 

cable to the fixture using one of the safety cable rigging points integrated in the base assembly.

FUSE REPLACEMENT

• 

With a flat head screwdriver wedge the fuse holder out of its housing. 

•  Remove the damaged fuse from its holder and replace with exactly the same type of fuse.
•  Insert the fuse holder back in its place and reconnect power.
• 

The fuse is located inside this compartment. Remove using a flat head screwdriver.

FIXTURE LINKING

You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to run 

synchronized shows on two or more fixtures set to a master/slave operating mode. The combined number of 

channels required by all fixtures on a serial data link determines the number of fixtures that the data link can 

support.

Console

Light1

Light2

Light3

Important

: Fixtures on a serial/data link must be daisy chained in one single line.  Maximum recommended seri

-

al data link distance: 100 meters. Maximum recommended number of fixtures on a serial data link: 32 fixtures

CABLE CONNECTORS

Cabling must have a male XLR connector on one end and a female XLR connector on the other end.

Summary of Contents for E-BEEDREAM100

Page 1: ...er letzten Seite NL Scan voor meer talen de QR code op de laatste pagina ES Para m s idiomas escanee el c digo QR en la ltima p gina RO Pentru mai multe limbi v rug m s scana i codul QR de pe ultima p...

Page 2: ...ise rotation from slow to fast 8 Gobo 0 7 White 8 15 Gobo 1 16 23 Gobo 2 24 31 Gobo 3 32 39 Gobo 4 40 47 Gobo 5 48 55 Gobo 6 56 63 Gobo 7 64 73 Gobo 7 shake from slow to fast 74 83 Gobo 6 shake from s...

Page 3: ...ark in a triangle indicates particular risks in handling or operating the appliance The unit complies with UK standards For indoor use only Protection class I Requires an earth connection 0 5m Minimum...

Page 4: ...e to which you are attaching the unit is secure and able to support a weight of 10 times of the unit s weight Also always use a safety cable that can hold 12 times the weight of the unit when installi...

Page 5: ...g fixture and so on Often the set up for Master Slave and Stand alone operation requires that the first fixture in the chain be initial ized for this purpose via either settings in the control panel o...

Page 6: ...from incorrect handing improper use or wear and tear We reserve the right to make technical modifications SPECIFICATIONS Power supply 100 240 50 60Hz Consumption 180W LED Spot 1x white 100W LED B eye...

Page 7: ...ue la tension secteur convient cet appareil et qu elle ne d passe pas la tension d alimenta tion indiqu sur la plaque signal tique de l appareil Uniquement pour utilisation l int rieur L appareil doit...

Page 8: ...e C est la combinaison de l attache om ga fournie et du point de fixation du c ble de s curit Lorsque vous installez cet appareil sur une traverse utilisez un crochet compatible avec l attache om ga e...

Page 9: ...ous de l cran LCD Touche Fonction MENU Acc s au menu ou retour vers une option pr c dente du menu UP D filement des options du menu dans un ordre croissant DOWN D filement des options du menu dans un...

Page 10: ...ouvements Pan 540 Tilt 190 16 bit avec r glage fin Disque de couleurs 7 couleurs blanc effet rainbow flow Gobo 7 gobos ouvert gobo shake gobo flow Dimmer 0 100 lineaire Stroboscope 25 flashes sec Dime...

Page 11: ...chluss des Ger ts berpr fen Sie muss mit der auf der R ckseite des Ger ts angegebenen Spannung bereinstimmen und darf auf keinen Fall h her sein Das Ger t geh rt zur Schutzklasse 1 und darf nur an ein...

Page 12: ...MX512 VERBINDUNG MIT DMX ABSCHLUSSWIDERSTAND Bei Installationen mit langen Kabelwegen oder in einer elektrisch gest rten Umge bung wie z B in einer Diskothek empfiehlt es sich einen DMX Abschlusswider...

Page 13: ...omplett reinigen bevor Sie das Ger t wieder ans Netz anschlie en K hlschlitze und Ventilatoren regelm ig reinigen TECHNISCHE DATEN Versorgung 100 240V 50 60Hz Verbrauch 180W LED Spot 1 weisse 100W LED...

Page 14: ...handleiding Wees zeker dat u het toestel op de juiste spanning aansluit en dat de lichtnetspanning niet hoger dan de op de zijde van het toestel aangegeven spanning is Alleen voor gebruik binnenshuis...

Page 15: ...e kabel moet een afgeschermde tweedraadskabel zijn met XLR in en uitgangsconnec toren Console Light1 Light2 Light3 DMX512 AANSLUITING MET DMX AFSLUITWEERSTAND Voor installaties over lange afstanden of...

Page 16: ...Wij zijn niet aansprakelijk voor schade die voortvloeit uit onjuiste overdracht oneigenlijk gebruik of slijtage We behouden ons het recht voor technische wijzigingen aan te brengen SPECIFICATIES Voed...

Page 17: ...y mantenimiento de este aparato Guarde el manual para referencia futura Si el dispositivo alguna vez cambia de propietario aseg rese de que el nuevo usuario tenga el manual Aseg rese de que la tensi n...

Page 18: ...paso Puede instalar este aparato en cualquier posici n siempre que haya una ventilaci n adecuada Al elegir una ubicaci n tenga en cuenta la facilidad de acceso al dispositivo para el mantenimiento y...

Page 19: ...uso ma nipulaci n o desgaste del equipo Sujeto a modificaciones t cnicas CARACTER STICAS T CNICAS Alimentaci n 100 240 50 60Hz Consumo 180W LED Spot 1 LED blanco de 100W B Eye 6 LED RGBW 4 en 1 de 10W...

Page 20: ...NTO PERICOLO DI SCOSSE ELETTRICHE IMPORTANTI ISTRUZIONI DI SICUREZZA E AVVERTENZE DI PERICOLO Si prega di leggere attentamente queste istruzioni poich contengono informazioni importanti sull installa...

Page 21: ...l dispositivo durante il montaggio la rimozione o la manutenzione dell ap parecchiatura Questo dispositivo pu essere montato in qualsiasi posizione purch vi sia spazio sufficiente per la ventilazione...

Page 22: ...n fem mina al connettore di ingresso dell apparecchiatura successiva costituito da un connettore a 3 pin maschio Quindi procedere alla connessione dall uscita come indicato sopra all ingresso del disp...

Page 23: ...ione errata uso improprio o usura Ci riserviamo il diritto di apportare modifiche tecniche SPECIFICHE Alimentazione 100 240 50 60Hz Consumo 180W Faretto LED 1 LED bianco da 100 W B eye 6 LED RGBW 4 in...

Page 24: ...RICOL DE ELECTROCUTARE INSTRUC IUNI IMPORTANTE DE SIGURAN I AVERTISMENTE DE PERICOL V rug m s citi i cu aten ie aceste instruc iuni acestea includ informa ii importante despre instalarea utili zarea i...

Page 25: ...i c nd instala i dispozitivul Nu sta i niciodat direct sub dispozitiv c nd monta i demonta i sau ntre ine i dispozitivul Acest dispozitiv poate fi montat n orice pozi ie cu condi ia s existe spa iu ad...

Page 26: ...ozitive i a a mai departe Adesea configurarea pentru operarea Master Slave i Stand alone necesit ca primul dispozitiv din lan s fie ini ializat n acest scop fie prin set ri din panoul de control fie p...

Page 27: ...ntem r spunz tori pentru daunele rezultate din manipularea incorect utilizarea necorespunz toare sau uzura Ne rezerv m dreptul de a face modific ri tehnice SPECIFICA II Alimentare 100 240 50 60Hz Cons...

Page 28: ...LOTRONIC 2023 Any question or problem Contact us via facebook View the product on our website Follow us on Instagram Imported from China by LOTRONIC S A Avenue Z nobe Gramme 9 B 1480 Saintes www ibiza...

Reviews: