background image

SUB15A / SUB18A

4

© Lotronic 2019

• 

When using a rack, make sure it is in a stable position and is transported securely. Installation on uneven, 

slanted surfaces or stopping the rack abruptly during transport can result in the rack overturning or ap-

pliances falling from or out of the rack and injuring people.

• 

Live components can be exposed by opening covers or removing components (unless this can be done wit-

hout tools). Contact points can also be live. If the appliance has to be opened in order to calibrate, service, 

repair or replace components or assemblies, all of its poles must be disconnected from all sources of voltage 

first. If the appliance has to be kept open and under voltage during maintenance or repairs, this work may 

only be carried out by a specialist who is familiar with the risks involved and the relevant regulations.

• 

Do not place any naked flames such as those of burning candles on or next to the appliance.

• 

Do not place the appliance on soft surfaces such as carpets or beds. Do not cover the air vents of the ap-

pliance. Do not obstruct the air circulation with objects such as magazines, table cloths or curtains. This 

prevents the dissipation of heat from the appliance and can result in overheating.

• 

Only use the appliance in a moderate climate, not in tropical environments.

• 

All persons involved in operating, installing and servicing the appliance and putting it into service must be 

trained and qualified accordingly and observe these operating instructions.

• 

Defective mains cables may only be replaced by specialists. Danger of shock hazard!

DISCONNECTION FROM THE MAINS

• 

Where the MAINS plug or an appliance couples is used as the disconnect device, the disconnect device shall 

remain readily accessible.

• 

If a switch is used to disconnect the device, the switch and its function must be clearly identified and remain 

easily accessible.

FEATURES

• 

Suitable for a 2-input amplified sound system

• 

2x Line inputs

• 

1x stereo AUX in- & output

• 

2-Band EQ (bass & treble)

• 

Bi-amp inside the subwoofer for the satellite speaker

• 

Speakon outputs for the satellites

• 

Separate volume controls for subwoofer & satellite speakers

INSTALLATION

Plug one end of the supplied mains lead into the IEC socket (13) and the other end into a suitable mains outlet.

OPERATION

1. 

Prior to switching the unit on, turn all volume controls down to minimum.

2. 

Connect your audio source to the appropriate input socket.

3. 

Connect the unit to the mains supply.

4. 

Switch on the audio source first, followed by the active speaker.

5. 

Set the volume with the applicable control.

6. 

Adjust the bass & treble.

CONTROLS AND CONNECTIONS

1. 

MIC volume control

2. 

Bass control: Set the level of the low frequencies from -12dB to +12dB

3. 

Treble control: Set the level of the high frequencies from -12dB to +12dB 

4. 

Subwoofer volume control

5. 

Master Volume control

6. 

6.3mm Microphone input 

7. 

6.3mm Line input 

8. 

RCA AUX input for units such as CD player, tuner or mixer

9. 

RCA output

10. 

Satellite Speaker output 1

Summary of Contents for SUB15A

Page 1: ...d Utilisation p 6 DE Bedienungsanleitung S 9 NL Handleiding p 12 ES Manual de Uso p 15 RO Manual de Utilizare p 18 REF SUB15A SUB18A 15 38CM 800W 18 46CM 1200W CODE 15 2166 15 2168 ACTIVE SUBWOOFERS S...

Page 2: ...X MIN MAX 12 12 12 12 MIN MAX BASS TREBLE SUB VOL MASTER VOL MIC LINE SAT2 OUT OFF POWER SUB18A SHOCK HAZARD DO NOT OPEN THE HOUSING STROMSCHLAGGEFAHR NICHT DAS GEH USE FFNEN RISQUE DE CHOC LECTRIQUE...

Page 3: ...uarantee claims expire in such cases Unauthorized conversions and or modifications of the appliance are not permitted for safety and licensing reasons CE The appliance belongs to protection class I an...

Page 4: ...ing it into service must be trained and qualified accordingly and observe these operating instructions Defective mains cables may only be replaced by specialists Danger of shock hazard DISCONNECTION F...

Page 5: ...CROPHONE Connect the microphone to the MIC socket 6 and switch it on Note If you are playing music from any other input connecting the microphone will not mute the sound output FUSE REPLACEMENT Discon...

Page 6: ...5 C pendant le fonctionnement Tenir l abri des vibrations fortes et des contraintes m caniques Tenir l abri de l humidit extr me due de l eau pulv ris e p ex Ne pas poser de r cipients remplis de liqu...

Page 7: ...ignes Remplacer les c bles secteur d fectueux uniquement par un sp cialiste Risque d lectrocution DISPOSITIF DE COUPURE DU SECTEUR Lorsque le cordon d alimentation ou un coupleur d appareil est utilis...

Page 8: ...r la fiche MIC et mettez le sous tension Note Le fait de brancher un microphone ne coupe pas le son de la source en cours de lecture REMPLACEMENT DU FUSIBLE Attention D branchez l appareil du secteur...

Page 9: ...zimmern oder am Swimmingpool benutzen Das Ger t geh rt zur Schutzklasse I und darf nur an eine geerdete Netzsteckdose angeschlossen werden Das Ger t vor extremen Temperaturen sch tzen 5 C 35 C Das Ge...

Page 10: ...Klimazonen nicht in tropischer Umgebung benutzen Alle Personen die mit der Bedienung Installation und Wartung des Ger ts zu tun haben m ssen ausgebildet und qualifiziert sein und diese Bedienungshinwe...

Page 11: ...egel vermin dern um Klangverzerrung zu vermeiden nur SUB18A MIKROFONANSCHLUSS Mikrofon an die MIC Buchse anschliessen und einschalten Hinweis Durch den Anschluss eines Mikrofons wird der Klang der and...

Page 12: ...ties Elke aanspraak op garantie vervalt in dergelijke ge vallen Onbevoegde conversies en of wijzigingen van het apparaat zijn niet toegestaan voor reden van veiligheid en vergunningen CE Dit apparaat...

Page 13: ...toppen Dit voorkomt de afvoer van warmte uit het apparaat en kan leiden tot oververhitting Gebruik het apparaat alleen in een gematigd klimaat niet in een tropische omgeving Alle personen die dit appa...

Page 14: ...stel is aangeschakeld alleen SUB18A 17 Clip LED Indien deze led oplicht heeft het signaal het maximum bereikt Verminder het ingangsniveau om geluidsvervorming te vermijden alleen SUB18A AANSLUITING VA...

Page 15: ...el agua pulverizada humedad ambiente No coloque recipientes con l quidos encima o en las proximidades del equipo ya que se puede verter el contenido dentro del equipo y producir da os materiales y co...

Page 16: ...dispositivo debe permanecer f cilmente accesible Si un interruptor omnipolar es utilizado como dispositivo de desconexi n el emplazamiento de este debe estar descrito en el aparato y el interruptor h...

Page 17: ...y enci ndalo Nota El hecho de conectar un micr fono no corta el sonido de la lectura en curso REMPLAZAMIENTO DEL FUSIBLE Atenci n Desenchufe el aparato del enchufe antes de cambiar el fusible El fusib...

Page 18: ...lare in corecta sau de nerespectarea instructiunilor de siguranta Orice reclamatii privind garantia expira in astfel de cazuri Transformari neautorizate si sau modificari aduse aparatului nu sunt prem...

Page 19: ...i cum ar fi covoare sau paturi Nu acoperiti orificiile de ventilatie ale aparatului Nu impiedicati circula ia aerului cu obiecte cum ar fi reviste fete de masa sau perdele Acest lucru previne evacuare...

Page 20: ...C i porni i l Not Dac reda i muzic de la oricare intrare conectarea microfonului nu va dezactiva sunetul INLOCUIREA SIGURANTEI Deconectati cablul de alimentare inainte de a inlocui o siguranta Inlocui...

Reviews: