6.2  Installation 

 

WARNING.

  Always  ensure there  is  sufficient  clearance  around  the table  before 

activating  the  various  movements  to  avoid  collisions  with  the  environment, 
equipment and people. 

 

WARNING.

 ECHO-

FLEX™ table is designed for indoor use on flat surfaces.

 

 

WARNING.

 Always lock wheels before the patient is placed on table.

 

 

WARNING.

 Never use braking system to stop a moving table.

 

 

WARNING.

 Do not leave patient unattended. 

 

WARNING. 

Do not use in oxygen-rich environment. 

 

WARNING.

 Do not use in MRI environment. 

 

WARNING.

 Do not use in wet environment. 

 

WARNING.

 Do not use for CPR or X-ray procedures or with defibrillator.

 

 

WARNING.

 Do not roll on power cable, hand or foot control cable. 

 

WARNING.

 Keep all cables out of reach of children. 

 

WARNING.

 Keep all cables away from moving parts. 

 

WARNING.

 Do not move table by pulling hand control, power cable or any other 

cable. 

 

WARNING.

  Never  use  the  table  if  the  power  cable  or  any  other  cables  are 

damaged. 

 

WARNING.

 Keep the power cable out of heat sources. 

 

WARNING.

 Never exceed duty cycle of 2/18 (2 minutes ON and 18 minutes OFF).

 

 
ECHO-

FLEX™ table is delivered fully assembled and ready for use. The table must be unpacked 

and inspected upon receipt to ensure that there has been no damage during transport. 
 

1.  Position  table  to  desired  location. 

IMPORTANT

:  Make  sure  you  have  enough  space 

around table to avoid collisions between its surroundings in ALL POSITIONS. Dimensions 
show  maximum  space  needed.  Dimensions  may  be  less  than  the  one  indicated  below 
depending on options. 

 

Summary of Contents for ECHO-FLEX 5002

Page 1: ...N MANUAL ECHO FLEX 5002 IBIOM Instruments Ltd 670 Joseph Louis Mathieu Street Sherbrooke Quebec J1R 0X3 Tel 1 877 563 5777 Fax 450 445 9837 info ibiom com OPERATION MANUAL Revision January 2021 ECHO F...

Page 2: ...12 6 4 Table functions 13 6 5 Security rail and cardiac cutout 15 6 6 Positioning cushion 17 6 7 IV pole 18 6 8 Rechargeable battery 19 6 9 Cardiac cutout in backrest 20 7 CLEANING INSTRUCTIONS 21 7 1...

Page 3: ...have the following information ready 7 digit serial number example 1234567 Model number or name example 5002 This information is available on label located on base of the table Phone 1 877 563 5777 F...

Page 4: ...a situation which if not avoided could result in death or serious injury It may also describe potential serious adverse reactions and safety hazards Warning electrical shock hazard Operator must read...

Page 5: ...205kg on table Safe working load includes patient s weight and accessories WARNING Never exceed safe working load of 150lb or 68kg on cardiac cutout WARNING Never exceed safe working load of 150lb or...

Page 6: ...y rail is closed make sure it is securely locked WARNING Once cardiac cutout is closed make sure it is securely locked WARNING Once positioning cushion is in place make sure it is securely locked WARN...

Page 7: ...s name and address Product code or name 7 digit serial number Product s weight Date of manufacture YYYY MM DD Maximum safe working load maximum patient weight Made in Canada QR code pointing to IBIOM...

Page 8: ...ill beeps hold down 2 buttons together of Trendelenburg adjustment 3rd row at the same time until it stops beeping It will reset all errors in control box b Control box will beep but table will not mo...

Page 9: ...ith defibrillator WARNING Do not roll on power cable hand or foot control cable WARNING Keep all cables out of reach of children WARNING Keep all cables away from moving parts WARNING Do not move tabl...

Page 10: ...OPERATION MANUAL ECHO FLEX 5002 Copyright IBIOM Instruments ltd 2021 Page 10 of 31 Revision January 2021...

Page 11: ...2 Once in place install all accessories IV pole arm board if applicable 3 Once in place lock all wheels 4 Remove any remaining packaging from the product Example Protective plastic on the hand control...

Page 12: ...ficient clearance around the table before activating the various movements to avoid collisions with the environment equipment and people WARNING Do not use ECHO FLEX table as a transport stretcher to...

Page 13: ...NING Medical staff should inform the patient on how to adjust table WARNING If patient is not able to adjust table the hand control should be placed out of the patient s reach WARNING Avoid placing ha...

Page 14: ...e foot control Button Function A Move up table B Move down table C Tilt up back rest section D Tilt down back rest section Triple foot control Button Function A Move up table B Move down table C Tilt...

Page 15: ...re it is securely locked WARNING Once cardiac cutout is closed make sure it is securely locked WARNING Always raise security rail once the patient is in place WARNING Do not leave patient unattended W...

Page 16: ...PERATION MANUAL ECHO FLEX 5002 Copyright IBIOM Instruments ltd 2021 Page 16 of 31 Revision January 2021 Security rail lowered down Cardiac cutout opened Cardiac cutout opened Security rail lowered dow...

Page 17: ...m WARNING Once positioning cushion is in place make sure it is securely locked WARNING Do not leave patient unattended To lift positioning cushion pull handle Move up cushion to one of the 3 positions...

Page 18: ...7 IV pole WARNING Always ensure there is sufficient clearance around the table before activating the various movements to avoid collisions with the environment equipment and people WARNING Never exce...

Page 19: ...ry may develop excessive heat CAUTION NEVER discharge completely battery or it may be damaged and reduce its lifetime Always allow battery to settle to room temperature before use Do not exceed duty c...

Page 20: ...body parts near moving parts or locking mechanism WARNING Once cardiac cutout is closed make sure it is securely locked WARNING Do not leave patient unattended WARNING Always have patient enter and ex...

Page 21: ...ther products or in concentration other than those specified in this section WARNING Do not use abrasive cleaning products WARNING Avoid placing hands and other body parts near moving parts or locking...

Page 22: ...l mattress surfaces including surfaces in openings between the backrest and main section IMPORTANT Allow the surfaces to dry before raising the backrest o NOTE In case of major spill it is possible to...

Page 23: ...ckrest 0 to 80 Adjustable height 21 to 37 in 53 to 94 cm Trendelenburg 0 to 15 Reverse Trendelenburg 0 to 15 Security rail length 24 in 61 cm Maximum safe working load 450 lb 205 kg Wheel diameter 5 i...

Page 24: ...tery capacity option 1 3 Ah Protection class IP Control box IPX6 Actuator IPX4 Lifting column IPX6 Hand control IPX6 Double foot switch IPX6 Triple foot switch IP20 Button controller IPX0 Battery IPX6...

Page 25: ...IBIOM Instruments ltd 2021 Page 25 of 31 Revision January 2021 8 4 Certification All IBIOM s product are certified according to CSA standard for electrical medical device except contrary indication La...

Page 26: ...ion or by misuse of the user guide instructions and warnings Also it doesn t apply if modifications or repairs have been done by someone not authorized by IBIOM instruments ltd Electrical components a...

Page 27: ...dispose of it properly in accordance with the regulations in force in your region Before disposal equipment must be clean properly to avoid contamination Equipment can be disposed of by separating th...

Page 28: ...OPERATION MANUAL ECHO FLEX 5002 Copyright IBIOM Instruments ltd 2021 Page 28 of 31 Revision January 2021 11 MAINTENANCE See service manual...

Page 29: ...the movements If problem persists go to next cause CAUTION Never allow the battery to discharge completely as this may damage the battery Green light on the control box with or without audible alarm...

Page 30: ...OPERATION MANUAL ECHO FLEX 5002 Copyright IBIOM Instruments ltd 2021 Page 30 of 31 Revision January 2021 13 SPARE PARTS LIST See service manual...

Page 31: ...RATION MANUAL ECHO FLEX 5002 Copyright IBIOM Instruments ltd 2021 Page 31 of 31 Revision January 2021 IBIOM INSTRUMENTS LTD 670 JOSEPH LOUIS MATHIEU STREET SHERBROOKE QU BEC J1R 0X3 CANADA www ibiom c...

Reviews: