![IBEX TS106 Use And Maintenance Manual Download Page 10](http://html1.mh-extra.com/html/ibex/ts106/ts106_use-and-maintenance-manual_3253189010.webp)
10
1. G
REASING
At the scheduled time on diagram "A", grease points "B" “C”, “D”,”E”, “F”, “G”.
Greasing point is equipped with greaser HYDRAULIC TYPE MODEL "A" UNI 7663.
To greasing use only MULTIFUNCTIONAL GREASE LITHIUM BASED Type NLGI 2.
2.
O
IL CHECK - OIL REPLACEMENT IN GEAR BOX
At the scheduled time on diagram "A", check or replace oil into gear box.
To fill oil use only OIL SAE 140 EP.
Gear box capacity: 0,8 L
a) To check oil level into the gear box, operate as follow :
1. With the machine on level unscrew plug "A" then check that oil touches on lower hole rim.
2. If the level is ok, screw plug "A".
3. If the level is slow, refill.
4. When the level is ok, screw plug "A".
b) To change oil into the gear box, operate as follow :
1. Unscrew plug "A" and take away oil using a suitable little pump.
2. Fill oil from plug "A".
3. When level is ok, screw plug “A”.