WARNING

Do not use this boiler if any 

part has been under water. 

Immediately call a qualified 

service technician to inspect 

the boiler and to replace any 

part of the control system and 

any gas control that has been 

under water.

DANGER

Should overheating occur 

or the gas supply fails to 

shut off, do not turn off or 

disconnect the electrical 

supply to the pump. Instead 

shut off the gas supply at 

a location external to the 

appliance

WARNING

Keep boiler area free 

and clear of combustible 

materials, gasoline, and  

other flammable vapours  

and liquids.

WARNING

Combustion air must not be 

drawn from areas containing 

corrosive air from swimming 

pools or spas, including air 

directly next to outdoor pools 

and spas.

WARNING

The boiler shall not be 

exposed to water leaks from 

piping or components located 

overhead. This includes 

condensation dropping from 

un-insulated cold water lines 

overhead.

WARNING

In areas of high snow fall, 

users must check side wall 

exhaust vent and air intake 

terminations on a regular 

basis to ensure blockages do 

not occur.

WARNING

Bacteria growth can develop 

in domestic hot water tanks 

and indirect water heaters 

if the minimum water 

temperature is not set high 

enough to prevent its growth.

Summary of Contents for SL SERIES

Page 1: ...pliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a nearby phone Fo...

Page 2: ...information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life WARNING Points out a potentially hazardous situation which mu...

Page 3: ...3 USER S INFORMATION MANUAL SL SERIES BOILERS WARNINGS 3 IBC BOILER CONTROLLER 6 LIGHTING AND SHUTTING DOWN THE BOILER 8 MAINTENANCE 9 SERVICE RECORD 11 CONTENTS...

Page 4: ...llows Acidity pH is to be between 6 5 and 8 5 Chloride is to be less than 125 mg l Iron is to be less than 0 3 mg l Cu less than 0 1 mg l Conductivity is to be less than 400 S cm at 25 C Hardness is t...

Page 5: ...tible materials gasoline and other flammable vapours and liquids WARNING Combustion air must not be drawn from areas containing corrosive air from swimming pools or spas including air directly next to...

Page 6: ...e Home Screen Internet LAN connectivity BACnet with activation Control When the boiler is first energized the controller will go through a power up sequence that will take approximately 90 seconds Dur...

Page 7: ...play will be showing the Home screen that includes details of the current boiler status If the controller has been left on the Home screen long enough user adjustable 10 minutes by default the display...

Page 8: ...USER S INFORMATION MANUAL 8 SL SERIES BOILERS LIGHTING AND SHUTTING DOWN THE BOILER clockwise open close...

Page 9: ...r and vacuum if required Check for water gas and condensate leaks in the boiler and around the boiler Check the condensate trap and clean if required Re fill the trap and re install the trap hook Chec...

Page 10: ...chemicals or glycol solutions If the system employs plain water the boiler auto fill valve must be turned on in order to recharge the lost fluid Blocked Vent Safety System The boiler is equipped with...

Page 11: ...11 USER S INFORMATION MANUAL SL SERIES BOILERS SERVICE RECORD DATE LICENSED CONTRACTOR DESCRIPTION OF WORK DONE...

Page 12: ...USER S INFORMATION MANUAL 12 SL SERIES BOILERS NOTES...

Page 13: ...13 USER S INFORMATION MANUAL SL SERIES BOILERS NOTES...

Page 14: ...E MUST NOT BE USED UNLESS AT LEAST ONE OF THE FOLLOWING CONDITIONS IS TRUE An external energy management system is installed that reduces the boiler water temperature as the heating load decreases Thi...

Page 15: ...REVISION HISTORY R1 JULY 2014 Initial release R2 MAY 2015 Address update...

Page 16: ...IBC Technologies Inc 8015 North Fraser Way Burnaby BC Canada V5J 5M8 Tel 604 877 0277 Fax 604 877 0295 www ibcboiler com 120 203 A R2 May 2015 IBC Technologies Inc 2015...

Reviews: