Troubleshooting

The technology upon which the Series 255/940
control is based, is well established and proven in
service over many years. However, should a problem
or question arise regarding the operation of the
system, the control can be very easily serviced. The
control module can be quickly replaced or
adjustments can be made at the installation. For parts
mentioned, refer to exploded views in the

Replacement Parts

 section of this manual.

IMPORTANT: 

Service procedures that require the

water pressure to be removed from the system are
marked with a 

!

 after the possible cause. To remove

water pressure from the system, put the bypass valve
or three-valve bypass into the bypass position and
open the Rinse Drain Valve (the fifth valve back from
the control) with a screwdriver, Figure 11. Restore
system water pressure when the service work is
completed.

Problem

Cause

Solution

1.  Control will not
      regenerate automatically

a.  Electric cord unplugged
b.  Defective Timer motor
c.  Day pins not down on calendar

cap.

d.  Binding in gear train of timer

a.  Connect power
b.  Replace motor
c.  Depress pins for days regeneration

required

d.  Replace timer

2.  Control regenerates at

Wrong time of day

a.  timer set incorrectly.

a.  Correct setting according to
       Instructions.

3.  Control will not draw

Brine.

a.  Low water pressure.

b.  Restricted drain line.
c.  Injector plugged. 

!

d.  Defective injector. 

!

e.  Valve disc 2 and/or 3 not closed.

f.  Air check prematurely closed.

a.  Water pressure must be 20 psi
      minimum.
b.  Remove restriction.
c.  Clean injector and screen.
d.  Replace injector cap.
e.  Flush out foreign matter holding disc(s)

open by manually operating valve
stem(s). Replace if needed.

f.  Put control momentarily into brine refill.

replace or repair air check if needed.
Refer to 

Brine Line Connection.

4.  Brine tank overflow.

a.  Brine valve disc1 being held open

By foreign matter.

b.  Uncontrolled brine refill flow rate.

c.  Valve disc 2 and/or 3 not closed

During brine draw causing brine
refill

d.  Air leak in brine line air check.

e.  Improper drain control for injector.

a.  Flush out foreign matter holding disc

open by manually operating valve stem.

b.  Remove and clean brine refill flow

control.

c.  Flush out foreign matter holding disc(s)

open by manually operating valve
stem(s).

d.  Check all connections in brine line for

leaks. Refer to 

Brine Line Connection.

e.  Too small of a drain control with a "B"

or "C" injector will reduce draw rates.
Reference 

Pressure Graphs.

5.  System using more or

less salt than salt control
Is set for.

a.  Inaccurate setting.
b.  Foreign matter in controller

Causing incorrect flow rates.

c. 

Defective controller. 

!

a.  Make correct setting
b.  Remove salt controller and flush out

foreign matter. Manually position
control to brine draw to clean
controller. After so doing, position
control to "brine/slow rinse" to remove
brine from tank.

c.  Replace defective part.

Summary of Contents for AST0922-940

Page 1: ...ION OPERATING INSTRUCTIONS Model AST0922 940 Serial No Telephone 07 3219 2233 Facsimile 07 3219 2266 Email sales ibcwater com au Website www ibcwater com au FILTRATION WATER TREATMENT PRODUCTS for com...

Page 2: ...oximately 20ppm based on a sample volume of 10mls Other hardness test kits are available for more accurate testing eg Hardness Tablets Directions Take a 50ml sample of water in a screw capped bottle A...

Page 3: ...age in litres call D For household situations allow 250 litres per person per day CALCULATION N 1000 x C D x H Select nearest lower whole number If necessary consult your dealer or IBC Water Treatment...

Page 4: ...s AST0922 940 770 1 4 1540 5 3 22 25 12 22 33 0 70 0 50 1 2 CABINET BRINE CHAMBER POLY MOULDED Operating Pressure 140 690 kPa Temperature 5o x 50o C Electrical 240V 50Hz 3 watts maximum WARNING A pres...

Page 5: ...t outlet pipes and drain line to control valve as per Instruction Booklet page 5 figure 3 Note The softener is supplied with the Autotrol Series 156 Bypass Valve as standard STEP 2 Remove lid from bri...

Page 6: ...TOP STRAINER SUPPLIED LOOSE IT IS IMPORTANT THAT THIS STRAINER IS ASSEMBLED TO THE VALVE DURING INSTALLATION THE LENGTH OF THE INTERNAL RISER PIPE IS FACTORY ADJUSTED FOR THE TANK SIZE PROVIDED DO NOT...

Page 7: ...the timer at the left hand side The Transformer is only suitable for indoor mounting When ordering spare parts Advise that the Timer is the low voltage model Salt Dial Indicator Knob Clock Dial Calend...

Page 8: ...AST0922 940 Page 8 Water Conditioning Control System Installation Operating and Maintenance Manual Series 255 Valve 940 Control...

Page 9: ...cing Conditioner into Operation 13 Adjustment of Timer 14 Special Features of Timer Adjustment of Brine Control 14 How to Set the Salt Dial Service 15 Removing the Timer Assembly Removing the Valve As...

Page 10: ...ve cycle operation provides for down flow service up flow backwash down flow brining down flow slow and fast rinse A sixth position is included for timed refill of the brine tank Valve discs are held...

Page 11: ...rol Bypass Valve optional Air Check Brine Tube Fitting Connection 1 4 Figure 2 Tank Adaptor Tank Tread 2 1 2 8 male NPSM Drain Connection 3 8 or 1 2 NPT or BSPT Outlet Connection 3 4 or 1 NPT or Inlet...

Page 12: ...ter pressure at the conditioner is not less than 40psi 280kPa You may elevate an additional 2ft 61cm for each additional 10psi 70kPa of water pressure When the drain line is elevated and empties into...

Page 13: ...ve s into the not in bypass position Open the water supply valve very slowly to approximately the 1 4 open position Caution If the water supply valve is opened too rapidly or too far resin may be lost...

Page 14: ...ndicator knob counterclockwise to START Figure 8 It will take a few minutes for regen eration to begin The normal regeneration schedule will not be disrupted Manual Regeneration Electricity is used on...

Page 15: ...imer assembly for servicing 1 Unplug the power cord 2 Remove the rear cover by pushing back on the tab provided on the cover with your thumb Figure 10 Next lift the cover off the valve 3 To remove the...

Page 16: ...camshaft Slide the camshaft into the timer It may be necessary to rock the timer slightly to key the camshaft into the timer When the camshaft is slid into place lift he back of the camshaft up while...

Page 17: ...teps to clean the injector screen and injector 1 Unplug the power cord 2 Shut off the water supply or put the bypass valve s into the bypass position and remove the rear cover Figure 10 3 Relieve syst...

Page 18: ...Pressure 300 psi 2069kPa Working Pressure 20 to 127 psi 138 to 876 kPa 100 psi max in Canada Voltage 24V 50 Hz 24V 60 Hz 100V 50 Hz 100V 60 Hz 230V 50 Hz 115V 60 Hz Current 50 mA Operating Temperature...

Page 19: ...1 2 in NPT male drain Valve Module Tank Adaptor Optional Bypass Valve Reinforced NORYL Inlet Outlet Manifold Brass or reinforced NORYL Rubber Parts Compounded for cold water service Injector size A W...

Page 20: ...AST0922 940 Page 20 Control Valving Identification Valve Disc Operation...

Page 21: ...AST0922 940 Page 21 Flow Diagrams...

Page 22: ...AST0922 940 Page 22...

Page 23: ...1000904 Adj Backwash Extra Salt Long Rinse Long Cycle 1000905 3 Cycle Adj Backwash 11 Motor Option 1 1000802 24V 50 Hz 1000803 24V 60 Hz 1000804 110V 50 Hz 1000805 100V 60 Hz 1000806 230V 50 Hz 10008...

Page 24: ...AST0922 940 Page 24...

Page 25: ...AST0922 940 Page 25 Valve Body and Tank Adaptor Module...

Page 26: ...No 14 for 14 in Diameter Tank 7 1030502 Ball Flow Control 1 8 Injector Assy With O rings 1 1032970 A Injector White 1032971 B Injector Blue 1032972 C Injector Red 9 Injector Cap With O rings 1 1000217...

Page 27: ...tic Pipe Adaptor Kit 1 1001605 1 in BSPT Plastic Pipe Adaptor Kit 1 1001611 3 4 in BSPT Brass Pipe Adaptor Kit 1 1001610 1 in NPT Brass Pipe Adaptor Kit 1 1001612 1 in BSPT Brass Pipe Adaptor Kit 1 Co...

Page 28: ...Restricted drain line c Injector plugged d Defective injector e Valve disc 2 and or 3 not closed f Air check prematurely closed a Water pressure must be 20 psi minimum b Remove restriction c Clean in...

Page 29: ...AST0922 940 Page 29...

Page 30: ...n be used directly without dissolving before application The recommended dosage for Calcium Hypochlorite is two grains approx 0 1 ounce per cubic foot Complete the following steps to disinfect the con...

Reviews: