For stress reasons, the universal connector must always be mounted in the direction of the roof ridge.
Attention!
The stress values for the M12x300 hanger bolt relate to a fixing distance l = 100mm for a use of
corrugated eternit panels. Exceeding the fixing distance has a detrimental effect on static values. The
calculation in the PV Manager software is based on a fixing distance of l = 100 mm.
Attention!
Always install universal connectors in each row of modules, as shown on the Figure 55
Figure 53 Correctly fitted hanger bolt with universal connector
Figure 54 Fixing distance
Figure 55 Mounted hanger bolt with "universal connector"