![IBASE Technology MPT-1000V User Manual Download Page 108](http://html1.mh-extra.com/html/ibase-technology/mpt-1000v/mpt-1000v_user-manual_3240887108.webp)
100
MPT-1000V User’s Manual
Getting Current CB & PB Value
Parameter:
GET_CURRENT_CB_PB_VOLTAGE
Gets current voltage form car battery and UPS battery.
Request:
Header Size Command
CRC
0xFF
0xEE
0x00 GET_CURRENT_CB_PB_VOLTAGE
Reply
Header Size Command
Data0
Data1
Data2 Data3 CRC
0xFF
0xEE
0x04 GET_CURRENT_
CB_PB_VOLTAGE
CB
(High
Byte)
CB
(Ligh
Byte)
PB
(High
Byte)
PB
(Ligh
Byte)
Round off to the 1
st
decimal place.
Ex. Setting 11.2V mapping to 11200 (11.2 x 1000) = 2BC0 (hex)
Data0 = 2B (hex)
Data1 = C0 (hex)
Setting PB 13.2V mapping to 13200 (13.2 x 1000) = 3390 (hex)
Data2 = 33 (hex)
Data3 = 90 (hex)
Setting CHG STV
Parameter:
SET_CHG_STV
Sets voltage value for start charging UPS battery.
Request:
Header Size Command
Data0
Data1
CRC
0xFF
0xEE
0x02 SET_CHG_STV
High
Byte
Low
Byte
Reply
Header Size Command
Data
CRC
0xFF
0xEE
0x00 SET_CHG_STV
None
Round off to the 1
st
decimal place.
Ex. Setting 13.2V mapping to 13200 (13.2 x 1000) = 3390 (hex)
Data0 = 33 (hex)
Data1 = 90 (hex)
Summary of Contents for MPT-1000V
Page 1: ...MPT 1000V Multi Purpose In Vehicle System User s Manual Version 1 0 August 2021...
Page 8: ......
Page 16: ...8 MPT 2000V User s Manual Oblique View...
Page 28: ...20 MPT 1000V User s Manual MBT 1002 bottom view...
Page 34: ...26 MPT 1000V User s Manual 2 4 10 SW6 System Reset Button...
Page 36: ...28 MPT 1000V User s Manual 2 5 1 CN1 USB 3 0 Port 2 5 2 CN2 Audio Line Out...
Page 75: ...BIOS Setup MPT 1000V User s Manual 67 4 4 4 6 CSM Configuration 4 4 7 Power Configuration...