ibaRackline
Manual
Issue 1.16
19
7.4
Installing ibaOut-Temp/ibaOut-State
The temperature and the status of the power supply unit can be monitored with the slot
cards ibaOut-Temp and ibaOut-State, see also chapter 5.4.
The installation procedure is identical for both cards. The following description is based
on the example of ibaOut-Temp.
ibaOut-Temp
Order no. 11.110001
ibaOut-State
Order no. 11.110002
After having opened the housing cover proceed as follows:
1.
ibaOut-Temp can be installed in one of the slots X20 to X26 (X20 is recommended).
2.
On the backside of the device, break out the cover plate of the slot where the card
is to be installed by means of a screw driver. (Slot X21 in the example below.)
3.
Above the slot, there is a screw in an opening, which is used to fix the card later.
Loosen the screw and remove it.