Manual
ibaFOB-PlusControl
18
Issue 1.1
Basic
Module type
Display of the module type (read only)
Locked
A locked module can only be modified by authorized users.
Enabled
The data acquisition for this module is either enabled (TRUE) or disabled (FALSE).
Name
Here, you can enter a module name.
Module No.
Logic module number for clearly referencing of signals e. g. in expressions in virtual
modules or ibaAnalyzer. The module number is assigned automatically by ibaPDA
in ascending order, but may be changed by the user.
Timebase
Timebase for data acquisition, cycles down to 10 µs are possible (depending on the
number of signals). Default setting is 25 µs.
Use name as prefix
If TRUE is selected, the module name is placed in front of the signal name as pre-
fix.
Groups
Generate groups
If TRUE is selected, the symbols are entered in the I/O manager groups according
to the structure in the address book which has already been generated for the pre-
ferred signals.
See also chapter 7.5 "Groups".
Module Layout
No. Analog signals
Defining the number of analog signals in this module.
No. Digital signals
Defining the number of digital signals in this module.
Note
When clicking in a field the corresponding description will be displayed in the text field
below the input fields. For a detailed parameter description please refer to the ibaPDA
manual.
Select symbols
Measurement values for this standard module can be selected using the PlusControl
symbol browser. A click on the blue link “Select symbols” opens the symbol browser.