background image

 

Manual 

ibaDeskline SAS 

 

36 

Issue 1.4 

 

 

9.2.5 

Completing installation 

 

The system files are copied to the drive and additional software is installed.  
The computer will restart twice.  
The procedure takes 30-40 min. depending on the hardware. 

 

9.3 

Windows Updates 

The automatic search for updates is deactivated by default on iba systems, as iba does 

not know which Windows update policies apply in your company.  
Please adjust the settings according to the update policies in your company. Consult 

your IT department if necessary. 
 

9.4 

Antivirus Software 

There is no antivirus software installed on iba systems in delivery state.  
Please install the antivirus software package which is used in your company by default. 

Consult your IT department if necessary.    
 

9.5 

Installing iba software 

The installation of iba software is described in the manuals included in delivery.  

Summary of Contents for 40.002005

Page 1: ...ibaDeskline SAS iba Industrial Computer Manual Issue 1 4...

Page 2: ...etely so that the full compliance is not guaranteed However the information in this publication is updated regularly Required corrections are contained in the following regulations or can be down load...

Page 3: ...Error monitoring 15 5 5 1 ibaOut Temp 16 5 5 2 ibaOut State 17 6 Installation connection and first switching on 18 6 1 Safety instructions 18 6 2 Setting up 18 6 3 Connection and first switching on 1...

Page 4: ...age 33 9 2 3 Enter the product key 33 9 2 4 Partitioning 34 9 2 5 Completing installation 36 9 3 Windows Updates 36 9 4 Antivirus Software 36 9 5 Installing iba software 36 10 Technical data 37 10 1 M...

Page 5: ...if he she is capable of assessing safety and recognizing possible consequences and risks on the basis of his her specialist train ing knowledge and experience and knowledge of the standard regulations...

Page 6: ...rol function The non observance of this safety information may result in a potential risk of death or severe injury The non observance of this safety information may result in a potential risk of inju...

Page 7: ...ftware license key when a software was ordered The documentation contains Manual pdf Third party documentation pdf Windows 10 Enterprise Long Term Servicing Version or Windows Server Version Recovery...

Page 8: ...unit The net volume corresponds to the volume of approx 6 hard disks with simultane ous high performance and system stability against failure Server system with Windows Server 2016 or higher ibaDeskl...

Page 9: ...t for several minutes until the com ponents have cooled down Thus you will avoid injuries due to the electric shock or burns Connect the device to one supply voltage only according to specifications o...

Page 10: ...Manual ibaDeskline SAS 10 Issue 1 4 5 Description 5 1 Front view ibaDeskline Optical drive with integrated writing function Plug in slots for hard disks...

Page 11: ...ibaDeskline SAS Manual Issue 1 4 11 5 2 Top view ibaDeskline 1 USB 2 0 interfaces 2 USB 3 0 interfaces 3 Headset interface 4 Microphone interface 5 Power button 6 Reset button...

Page 12: ...external devices keyboard mouse network etc Slots X20 to X26 for low profile iba cards Slot X2 for hard disk controller Slots X3 to X7 PCIe in the example with 2 ibaFOB D cards1 Slot X8 DVI connectio...

Page 13: ...or external devices keyboard mouse network etc Slots X20 to X26 for low profile iba cards e g output connections of FOB 4i cards Slot X2 for hard disk controller Slots X3 to X7 PCIe in the example wit...

Page 14: ...ibaDeskline SAS 14 Issue 1 4 5 4 Internal view Power supply unit redundant for RAID systems PCIe slots Hard disk controller Slots for low profile iba cards Drive bracket Fan 12 cm Internal USB port d...

Page 15: ...ly as acces sory If the card is ordered with ibaDeskline it is installed by default in slot X20 If the plug in card is installed at a later time please refer to chapter 7 4 The status of temperature a...

Page 16: ...open Power OK temperature OK open open Power OK overtemperature open closed Contact loading capacity Nominal current 400 mA Nominal voltage 60 V Compatibility to previous models ibaDeskline computers...

Page 17: ...wer off or Power error and overtemperature Power error temperature OK Power OK overtemperature Contact loading capacity Nominal current 300 mA Nominal voltage 220 V DC Compatibility to previous PC mod...

Page 18: ...ice only to earthed power networks TN networks according to VDE 0100 Part 300 or IEC 60364 3 The operation via ungrounded networks or networks IT networks earthed via imped ance is not permitted Never...

Page 19: ...The device is delivered in a pre installed and configured state You can find the parameters of the operating system and ibaSoftware in the corresponding manuals or in the Online Help 1 Connect the dev...

Page 20: ...n the housing Electrostatic discharge Touch the components only in electrostatically discharged state Note If you upgrade the device observe the instructions in the third party documentation Back up a...

Page 21: ...aDeskline SAS Manual Issue 1 4 21 7 3 Opening the device 1 At the rear side loosen the two screws fixing the side panel 2 Push the side panel slightly backwards 3 Tilt the side panel and pull it upwar...

Page 22: ...is described below using the example of ibaOut Temp in an ibaRackline system ibaOut Temp Order no 11 110001 ibaOut State Order no 11 110002 After having opened the housing cover proceed as follows 4...

Page 23: ...s only in electrostatically discharged state Hold the card cautiously at the edges and at the slot bracket 7 Insert the card in the respective slot The bar at the bottom is used to fix the card 8 Fast...

Page 24: ...nec tion is not necessary when a standard power supply unit is used 2 Power supply connection Use the cable included in delivery Connect the con nector of the power supply cable from the power supply...

Page 25: ...ibaDeskline SAS Manual Issue 1 4 25 10 Properly installed card 11 Fix the cable with a cable tie and close the housing cover...

Page 26: ...Carry out the maintenance work 7 Attach the side panels again 8 Put the device into operation again 8 2 Power supply slide in module for replacement of redundant power supply unit If the green lamp o...

Page 27: ...n electrostatically discharged state Important Note The RAID system is not automatically restored after having changed the hard disk Use the program Adaptec Storage Manager Note The DVD Adaptec Storag...

Page 28: ...t indicated 4 Mark the hard disk which is available Device 1 in the example above and click on the Locate icon in the Physical device section The available hard disk blinks in the drive frame 5 Replac...

Page 29: ...t the hard disk has not been registered in the system 7 Mark the new hard disk Device 2 in the example above and click on the Initialize icon in the Physical Device section 8 Then click on the Spare M...

Page 30: ...Manual ibaDeskline SAS 30 Issue 1 4 10 Confirm the following overview with Finish 11 The following message appears when the operation was successful Otherwise an error message appears...

Page 31: ...baDeskline SAS Manual Issue 1 4 31 12 The progress of the rebuild process is displayed under Tasks 13 As soon as the hard disk has been successfully registered in the system the pro gram can be closed...

Page 32: ...are e g drivers will be installed Do not change the basic configuration of the device components e g motherboard If you modify the device components it may not be possible to install it with the Recov...

Page 33: ...process 9 2 2 Select the language When the installation has started you can select the system language to be installed When using Windows 10 Enterprise or Windows Server the language can be changed su...

Page 34: ...ndows 10 Enterprise or Win dows Server Substitute the operating system on a drive already used substitute Windows 10 Enterprise with Windows Server or vice versa Possibility 1 New drive You use a new...

Page 35: ...9 2 5 Completing installation Possibility 3 Restoring or replacing the operating system The drive is already in use and you want to install the operating system 1 Mark the system partition usually 50...

Page 36: ...s as iba does not know which Windows update policies apply in your company Please adjust the settings according to the update policies in your company Consult your IT department if necessary 9 4 Antiv...

Page 37: ...ndensation Protection class IP20 Power supply ibaDeskline SAS standard 90 V to 264 V AC 110 V to 374 V DC 8 A 4 A 47 Hz to 63 Hz Power output ibaDeskline SAS standard Max 400 W ibaDeskline SAS RAID 10...

Page 38: ...x 10 Mbps 100 Mbps 1000 Mbps HD audio on board 7 1 channel HD Working memory 16 GB DDR3 RAM Slots PCI Express x16 for SAS RAID controller 5x PCI Express for iba measuring cards USB 2 0 USB 3 0 2 x bac...

Page 39: ...0 GB to 1200 GB Upgrade SAS HD 600 GB to 1800 GB Upgrade SAS HD 600 GB to 2400 GB Upgrade SAS On request Hard disk SSD SAS 400 GB ENTERPRISE Hard disk SSD SAS 800 GB ENTERPRISE Upgrade to RAID1 system...

Page 40: ...Manual ibaDeskline SAS 40 Issue 1 4 10 4 Device dimensions dimensions in mm...

Page 41: ...product Contact Headquarters iba AG Koenigswarterstrasse 44 D 90762 Fuerth Germany Phone 49 911 97282 0 Fax 49 911 97282 33 E mail iba iba ag com Mailing address iba AG Postbox 1828 D 90708 Fuerth Ge...

Reviews: