TECHNICAL DATA

Minimum dynamic pressure:_________________________________________________________0.5 bar
Maximum operational pressure:________________________________________________________5 bar
Recommended operational pressure:_________________________________________________1-5 bar
 

It’s recommended to use a pressure reducer in case of

 

static pressure superior than 5 bar inside the waterpipe.

Maximum hot water temperature:_______________________________________________________80°C

INSTALLATION, MAINTENANCE AND PRELIMINARY CHECKING PROCEDURE

In 

order to get your device work correctly and fi ne in time, must ensure compliance with the 

mode of installation and maintenance described in this booklet. Relying on a qualifi ed plumber. 
Make sure that the system is free from all debris and impurities existing.

INSTALLATION

Fig.1:

 Prepare the connection to the water supply with a G1 / 2” female attack in line with the 

wall, including coating. Use hemp or Tefl on to ensure proper seal.
Fig. 2: Insert the spout on the insert; screw the grubscrew until fully locked. After connecting 
the body to the system, turn on the stopcocks and check that the mixer tap unit operates cor-
rectly. Keep the tap pressurised for a few minutes checking eventual leaks. Insert the fi nishing 
rosette on the spout.

CLEANING

In order to obtain a correct cleanliness, exclusively wash them with soap and water, rewash and 
dry them with a soft towel and deerskin. Avoid the usage of alcohol, solvents, solid or liquid 
detergents which contain corrosive or acidic substances, abrasive sponges, swab with metallic 
strings because they could irreversibly compromise the surfaces.

THE USAGE OF THIS KIND OF DETERGNETS DURING THE CLEANING OF THE MIXER EXCLUDE 
IB RUBINETTERIE FROM ANY WARRANTY OBLIGATION.