background image

 EN

TECHNICAL DATA

Minimum dynamic pressure:_________________________________________________________0.5 bar
Maximum operational pressure:________________________________________________________5 bar
Recommended operational pressure:_________________________________________________1-5 bar
 

It’s recommended to use a pressure reducer in case of

 

static pressure superior than 5 bar inside the waterpipe.

Maximum hot water temperature:_______________________________________________________80°C

INSTALLATION, MAINTENANCE AND PRELIMINARY CHECKING PROCEDURE

In 

order to get your device work correctly and fi ne in time, must ensure compliance with the 

mode of installation and maintenance described in this booklet. Relying on a qualifi ed plumber. 
Make sure that the system is free from all debris and impurities existing.

INSTALLATION

FIG. 1:

 Make two holes MIN Ø27 mm - 1.06 in, MAX Ø33 mm - 1.3 in, into the support base 

in order to put the handles. Operating from the bottom of the base, insert the sidebody valve 
and the fi xing set. From the upper side, position the OR and the covering support. Screw the 
reduction component on the sidebody valve. Insert the handle by using the screw verifying the 
right opening/closing position. Lay the sidebody valve into the support and block it with the 
grub screw. Place the fi xing kit.

Fig. 2:

 Insert the marble cover on the support, fi xing it with the grub screw. Screw the lateral 

lever and verify the correct movement.

Fig. 3:

 Connect the fl exible to the sidebody valve.

Repeat these steps in order to mount the second handle.

Fig. 4:

 Make a Ø35mm - 1.37 in hole on the support base. From the upper side of it, insert the 

stem of the spout into the hole just created, positioning the OR. Stabilize the spout by using 
the proper fi xing kit.

Fig. 5:

 Link the fl exible to the spout.

Fig. 6:

 Make a MIN Ø35mm - 1.37 MAX Ø40mm - 1.57 in hole on the support base. From the 

upper side of it, insert the stem of the support into the hole just created, positioning the gasket 
for the endurance. Stabilize the support by using the proper fi xing kit. Insert the fl exible into the 
support after it’s screwed to the hand shower.

Fig. 7:

 Make a Ø30mm - 1.18 in, MAX Ø40 mm - 1.57 in hole on the support base. From the lower 

side of it, insert the diverter and the fi xing kit. On the upper side, place the OR, the little base 
and the covering support. Screw on the diverter the reduction metallic component. By using 
the screw, insert the handle verifying the correct opening/closing position. Lay the diverter into 
the support and block it by using the grub screw. Place the fi xing kit.

Fig. 8:

 Insert the marble cover on the support, fi xing it with the grub screw. Screw the lateral 

lever and verify the correct movement.

Fig. 9:

 Connect the fl exibles to the diverter as in frame on the image. Connect the sidebody 

valves to the hydric system.

After connecting the body to the system, turn on the stopcocks and check that the mixer tap 
unit operates correctly. Keep the tap pressurised for a few minutes checking eventual leaks.

Reviews: