installation
Once the number of zones for the wall switch has been selected place the zone labels
in the appropriate position on the front of the switch prior to sticking the overlay in place.
Connect the wall switch to the control box using the plug in cable.
Wall Switch Zone number Selection:
The jumper blocks on the back of the wall switches are used to set the number of zones
controlled by the switch.
The top button (
determined by the overlay used - not the switches on the hardware
) on
each wall switch corresponds to zone 1 output on the control box module.
Example
For a 2 button wall switch the top button and the bottom button of the wall switch
hardware are disabled by placing the jumper across the pins at JP3 on the back of the
wall switch. See image below.
Wall Switch Zone number Assignment - MpWS234:
MpWS234 Jumper position
Zones Controlled
Hardware Switches used
JP1 (Top)
1, 2, 3 and 4
1, 2, 3 and 4
JP2 (Middle)
1, 2 and 3
1, 2 and 3
JP3 (Bottom)
1 and 2
2 and 3
MpWS234
Zone Number