iAIRE, LLC
19
SHVAC
Residential Mini-Split and Mounting Kit I/O/M
SHMSPZ-24 | Solar HVAC Model “Z” Mini-Split Dimensions (cont’d)
12.88
8.81
39.63
Page 1: ...Solar HVAC Model Z Residential Mini Splits and Mounting Kits I O M manual PD 07 25 2023 v 1 00 PN IOM 0052...
Page 2: ...the appliance may result in personal injury and property damage The manufacturer or seller cannot be responsible for the interpretation of this information nor can it assume any liability in connectio...
Page 3: ...ion Clearances 26 Mounting Kit Part Numbers and Description 27 1 25 Ton Mounting Kit Dimensions 28 2 50 Ton Mounting Kit Dimensions 29 3 75 Ton Mounting Kit Dimensions 30 Wiring Diagrams 31 35 PCB Lay...
Page 4: ...roper service tools may result in equipment damage or personal injury Reconnect all grounding devices All parts of this product that are capable of conducting electrical current are grounded if ground...
Page 5: ...18 000 BTUs 24 24 000 BTUs 36 36 000 BTUs Options 4 0 No Options D Condenser Coil UG E Mounting Kit Y Start Up 7 Phase Monitor A Solar HVAC mini split is more than twice as efficient as a standard mi...
Page 6: ...M 6 Outdoor Unit Intdoor Unit F E Model in mm Indoor Unit Outdoor Unit A B C D E F G H I J K SHMSPZ 09 31 93 811 11 5 292 8 07 205 28 15 715 11 42 290 19 61 498 21 11 536 13 73 349 12 62 321 1 97 50...
Page 7: ...iAIRE LLC 7 SHVAC Residential Mini Split and Mounting Kit I O M 12 88 8 81 23 88 SHMSPZ 09 Solar HVAC Model Z Mini Split Dimensions cont d...
Page 8: ...Up to 400 Operation temperature F 60 8 87 8 Ambinet temperature Indoor cooling heating F 62 86 Outdoor cooling heating F 5 122 4 86 Electrical Mechanical Specifications Indoor Unit Indoor Motor Motor...
Page 9: ...Indoor Packing dimensions W x D x H mm 885x366x278 inch 34 84x14 40x10 94 Outdoor Packing dimensions W x D x H without pipe Outdoor mm 818x325x538 inch 32 20x12 80x21 18 Solar Box mm 664 13x356 79x24...
Page 10: ...M 10 SHMSPZ 12 Solar HVAC Model Z Mini Split Dimensions Outdoor Unit Intdoor Unit F E Model in mm Indoor Unit Outdoor Unit A B C D E F G H I J K SHMSPZ 12 31 93 811 11 5 292 8 07 205 28 15 715 11 42...
Page 11: ...iAIRE LLC 11 SHVAC Residential Mini Split and Mounting Kit I O M SHMSPZ 12 Solar HVAC Model Z Mini Split Dimensions cont d 12 88 8 81 23 88...
Page 12: ...P2 5F 15F W W 1 75 Suitable area sq ft Up to 550 Operation temperature F 60 8 87 8 Ambinet temperature Indoor cooling heating F 62 86 Outdoor cooling heating F 5 122 4 86 Electrical Mechanical Specifi...
Page 13: ...g 11 36363636 lbs 25 Indoor Packing dimensions W x D x H mm 885x366x278 inch 34 84x14 40x10 94 Outdoor Packing dimensions W x D x H without pipe Outdoor mm 818x325x538 inch 32 20x12 80x21 18 Solar Box...
Page 14: ...M 14 SHMSPZ 18 Solar HVAC Model Z Mini Split Dimensions Outdoor Unit Intdoor Unit F E Model in mm Indoor Unit Outdoor Unit A B C D E F G H I J K SHMSPZ 18 39 76 1010 12 4 315 8 66 220 30 71 780 13 74...
Page 15: ...iAIRE LLC 15 SHVAC Residential Mini Split and Mounting Kit I O M SHMSPZ 18 Solar HVAC Model Z Mini Split Dimensions cont d 12 88 8 81 39 63...
Page 16: ...P2 5F 15F W W 1 75 Suitable area sq ft Up to 1000 Operation temperature F 60 8 87 8 Ambinet temperature Indoor cooling heating F 62 86 Outdoor cooling heating F 5 122 4 86 Electrical Mechanical Specif...
Page 17: ...bs 70 6 Solar Box kg 11 36363636 lbs 25 Indoor Packing dimensions W x D x H mm 1096 390 300 inch 43 15x15 35x11 81 Outdoor Packing dimensions W x D x H without pipe Outdoor mm 890 385 640 inch 35 03x1...
Page 18: ...18 SHMSPZ 24 Solar HVAC Model Z Mini Split Dimensions Outdoor Unit Intdoor Unit F E Model in mm Indoor Unit Outdoor Unit A B C D E F G H I J K SHMSPZ 24 46 93 1192 14 17 360 10 24 260 33 27 845 14 96...
Page 19: ...iAIRE LLC 19 SHVAC Residential Mini Split and Mounting Kit I O M SHMSPZ 24 Solar HVAC Model Z Mini Split Dimensions cont d 12 88 8 81 39 63...
Page 20: ...2 5F 15F W W 1 75 Suitable area sq ft Up to 1500 Operation temperature F 60 8 87 8 Ambinet temperature Indoor cooling heating F 62 86 Outdoor cooling heating F 5 122 4 86 Electrical Mechanical Specifi...
Page 21: ...bs 90 4 Solar Box kg 22 72727273 lbs 50 Indoor Packing dimensions W x D x H mm 1265 435 337 inch 49 80x17 13x13 27 Outdoor Packing dimensions W x D x H without pipe Outdoor mm 950 420 750 inch 37 40x1...
Page 22: ...M 22 SHMSPZ 36 Solar HVAC Model Z Mini Split Dimensions Outdoor Unit Intdoor Unit F E Model in mm Indoor Unit Outdoor Unit A B C D E F G H I J K SHMSPZ 36 46 93 1192 14 17 360 10 24 260 35 83 910 14 1...
Page 23: ...iAIRE LLC 23 SHVAC Residential Mini Split and Mounting Kit I O M SHMSPZ 36 Solar HVAC Model Z Mini Split Dimensions cont d 8 86 18 88 40 71...
Page 24: ...5F 15F W W 1 75 Suitable area sq ft Up to 2500 Operation temperature F 60 8 87 8 Ambinet temperature Indoor cooling heating F 62 86 Outdoor cooling heating F 5 122 4 86 Electrical Mechanical Specific...
Page 25: ...114 6 Solar Box kg 34 09090909 lbs 75 Indoor Packing dimensions W x D x H mm 1265 435 337 inch 49 80x17 13x13 27 Outdoor Packing dimensions W x D x H without pipe Outdoor mm 1028 480 860 inch 40 47x1...
Page 26: ...iAIRE LLC SHVAC Residential Mini Split and Mounting Kit I O M 26 SHMSPZ xx Solar HVAC Model Z Mini Split Clearances Space to the ceilling...
Page 27: ...R MNT 05C75 50 7640 15 Ton A Solar HVAC Solar Mounting Kit allows mounting of a Solar Box in a sunny location away from the condensing unit to which it is plumbed The Solar Mounting Kit allows for wal...
Page 28: ...26 000in 660 4mm 12 875in 327mm 3 5 16 83 9mm 21 7 8 556mm 26 7 16 672mm 60 Cross braces adjustable to any position along back strut channel to mount to any wall Piping stubs to go to condensing unit...
Page 29: ...000in 1016mm 12 875in 327mm 3 7 16 87 6mm 29 13 16 757 7mm 40 3 8 1024 9mm 60 Cross braces adjustable to any position along back strut channel to mount to any wall Piping stubs to go to condensing un...
Page 30: ...765 6mm 3 7 16 87 6mm 40 13 16 1037 4mm Cross braces adjustable to any position along back strut channel to mount to any wall Piping stubs to go to condensing unit Strut mounting frame and hardware on...
Page 31: ...ntial Mini Split and Mounting Kit I O M Wiring Diagrams Air Conditioner Service Manual 5 3 Electric Diagram 3 1 Wiring diagram MODEL 9K 12K 18K 24K _ Power Supply from Indoor INDOOR UNIT OUTDOOR UNIT...
Page 32: ...iAIRE LLC SHVAC Residential Mini Split and Mounting Kit I O M 32 Wiring Diagrams cont d Air Conditioner Service Manual 6 MODEL 9K 12K 18K 24K _Power Supply from Outdoor INDOOR UNIT OUTDOOR UNIT...
Page 33: ...iAIRE LLC 33 SHVAC Residential Mini Split and Mounting Kit I O M Wiring Diagrams cont d Air Conditioner Service Manual 7 INDOOR UNIT OUTDOOR UNIT POWER BOARD...
Page 34: ...iAIRE LLC SHVAC Residential Mini Split and Mounting Kit I O M 34 Wiring Diagrams cont d Air Conditioner Service Manual 8 INDOOR UNIT OUTDOOR UNIT MAIN BOARD OG BU RD BK 1 N 2 M M N L L...
Page 35: ...C Residential Mini Split and Mounting Kit I O M Wiring Diagrams cont d Air Conditioner Service Manual 6 4 Electric Diagram 4 1 Wiring diagram INDOOR UNIT MODEL 36000BTU 230V 60Hz OUTDOOR UNIT MODEL 36...
Page 36: ...wer supply N connector 8 Anion connector 9 IDU ODU communication wiring 10 Up Down swing connector 11 Left Right swing connector 12 Display 13 Emergency button 14 AC Motor feedback 15 Temperature sens...
Page 37: ...pe A010270 1 ODU AC power output 2 Fuse 3 ODU AC power input 4 DC fan motor connection 5 IDU ODU wiring connection N connector 6 Power supply N connector 7 Anion connector 8 IDU ODU communication wiri...
Page 38: ...iAIRE LLC SHVAC Residential Mini Split and Mounting Kit I O M 38 PCB Layouts cont d Air Conditioner Service Manual PCB type A010403...
Page 39: ...oner Service Manual Outdoor unit 9K 12K PCB type A010313 PCB type A010386 1 ODU PCB Mainly relay 2 Fuse 3 L N 1 communication wiring 4 4 way valve 5 Heater 6 DC fan motor connector 7 Electronic expans...
Page 40: ...010286 Note OAT Outdoor Ambient Temperature OPT Outdoor pipe temperature 1 DRED OPTION 2 OAT OPT connector 3 Discharge sensor connector 4 Electronic expansion valve 5 AC DC fan motor connector 6 Heate...
Page 41: ...230V 60Hz Note OAT Outdoor Ambient Temperature OPT Outdoor pipe temperature 1 4 way valve P8 2 Heater CN11 3 L N Communication 4 FUSE1 5 ODU PCB Mainly relayRY QD1 6 DC Motor connector CN12 2 7 Electr...
Page 42: ...ling Mode Dry Mode Fan only Mode Heating Mode Fan speed Auto low low mid mid mid high high TURBO function Mute function Up down auto swing Temperature indicator Meaning Left right auto swing SLEEP fun...
Page 43: ...e time for timer on off TIMER To switch on off the function SLEEP SLEEP 10 To switch on off the LED display DISPLAY To stop or start horizontal louver movement or set the desired up down air flow dire...
Page 44: ...de t RT ST COOLING t 1 1 8 FAN 1 1 8 t 1 1 8 HEATING t 1 1 8 5 2 2 Cooling mode 5 2 2 1 Temperature control 16 31 60 8 87 8 and the operation of fan speed and vane position according to preset 5 2 2 2...
Page 45: ...to the lower frequency limit 5 Unit stop a When IPT 1 33 8 for 3min continuously unit stops working for anti defrosting protection b While IPT 6 42 8 and the unit stopped for 3 min already can the un...
Page 46: ...sor stops operation the fan motor will start working simultaneously 5 2 4 5 4 way valve control 1 On Cooling Dry Fan mode 4 way valve OFF when unit switched on heating mode 4 way valve ON 2 When heati...
Page 47: ...fan motor will change to preset speed b After compressor starts working 2 min fan motor change to preset speed directly 2 Vane blade operation for cold air prevention a If the vane works on status of...
Page 48: ...essed again within 3s HEATING mode selected while press once again the unit will be switched off When the remote controller out of function batteries lost power for example the EMERGENCY button in the...
Page 49: ...ode In the process of operation once the compressor runs continuously more than 6 min the counter of discharge over temperature stop working protection will be reset to zero and start a new counting p...
Page 50: ...URBO Function effective on Cooling Heating Fan and Auto modes and fan speed operates on highest 5 2 11 3 The communication control If ODU PCB can t get signal feedback from IDU for 2 min continuously...
Page 51: ...ries such as protective boards cable cross loop and wire clip 7 The live wire neutral wire and grounding wire of power supply must be corresponding to the live wire neutral wire and grounding wire of...
Page 52: ...lves is open and connecting pipe is not yet connected air will be sucked in and cause pressure rise and then compressor overheat or gas leak resulting in injury Prohibit installing the unit at the pla...
Page 53: ...2 6 11 24 43 68 115 R32 0 306 1 224kg 1 836kg 2 448kg 3 672kg 4 896kg 6 12kg 7 956kg 0 6 29 51 116 206 321 543 1 10 19 42 74 116 196 1 8 3 6 13 23 36 60 2 2 2 4 9 15 24 40 Caution Please contact the n...
Page 54: ...to the maintenance station and it is prohibited to weld the refrigerant pipe or conduct other operations on the user s site It is necessary to choose the place where the inlet and outlet air of the i...
Page 55: ...nce equipment Check the maintenance equipment is applicable to the refrigerant or not and it is only allowed to use the professional equipment recommended by the air conditioner manufacturer Check the...
Page 56: ...air exhausting equipment to prevent the refrigerant gas from aggregating It is necessary to provide some relevant instruments such as combustible refrigerant leak detector and have a leak detecting i...
Page 57: ...g the trial operation after finishing the maintenance it is a must to use a practical leak detector to inspect the leakage and reliability of ground connection in order to ensure that no refrigerant l...
Page 58: ...tandard Wrench Pipe Cutter Vacuum Pump Adjustable Crescent Wrench Screw drivers Phillips Flat blade Safety Glasses Torque Wrench Manifold and Gauges Work Gloves Hex Keys or Allen Wrenches Level Refrig...
Page 59: ...fere with the air flow Leave the spaces as shown in the picture for The air to circulate freely Install the outdoor unit in a safe and solid place If the outdoor unit is subject to vibration place rub...
Page 60: ...ean The hole must slope downwards towards the exterior Note Keep the drain pipe down towards the direction of the wall hole otherwise leakage may occur 2 5 3 Electrical connections Indoor unit 1 Lift...
Page 61: ...m entering If the pipe is bent or pulled too often it will become stiff Do not bend the pipe more than three times at one point When extending the rolled pipe straighten the pipe by unwinding it gentl...
Page 62: ...out maintenance easily Fasten the support to the wall using screw anchors which are particularly suited to the type of wall Use a larger quantity of screw anchors than normally required for the weigh...
Page 63: ...w the flare nuts to the outdoor unit coupling with the same tightening procedures described for the indoor unit Note If the tightening torque is not sufficient there will probably be some leakage With...
Page 64: ...rt to allow the Any Angle Bracket to rotate Mount Bottom Cross Brace either well above or well 3 below the Horizontal Support Positioning is determined by angle of Solar Box Note Larger 10 and 15 Ton...
Page 65: ...d through the Cross Braces For floor or roof mounting see next page 4 Mount Solar Box pipe pop outs on top with edge of strut channels touching to form a solid triangle Tighten strut channel nuts once...
Page 66: ...pletely 5 Tighten the screw caps of valve and refrigerant charging vent 2 Leakage Detection 1 With leakage detection Check if there is leakage with leakage detection 2 With soap water If leakage detec...
Page 67: ...ing Diagram FIELD SUPPLIED PLUMBING ON SPLIT SYSTEMS ONLY REFGT FLOW DIRECTION FOR HEAT OPERATION REFGT FLOW DIRECTION FOR COOLING OPERATION SOLAR HVAC MINI SPLIT HP PIPING DIAGRAM REVISION V0 01 1 0...
Page 68: ...6 30 Appendix 2 The Pipe length and Gas charging Connecting pipes size and length for installation Model Standard length m inch Refrigerant piping Max length m inch A Additional refrigerant charging X...
Page 69: ...4 9ft longer than the pipe length B Burrs removal 1 Completely remove all burrs from the cut cross section of pipe tube 2 Put the end of the copper tube pipe in a down ward direction as you remove bur...
Page 70: ...6 60 8 30 458 4 283 29 84 2 4 292 2 285 74 165 2 0 950 0 785 15 59 28 972 4 252 30 86 4 133 2 238 75 167 0 922 0 765 14 57 2 27 567 4 219 31 87 8 3 981 2 192 76 168 8 0 895 0 746 13 55 4 26 239 4 186...
Page 71: ...6 238 5 270 9 307 4 27 89 6 17 03 18 32 19 7 81 177 8 2 327 2 404 2 483 26 78 8 225 4 255 7 289 8 28 82 4 16 32 17 55 18 85 82 179 6 2 254 2 327 2 401 25 77 213 1 241 4 273 3 29 84 2 15 65 16 81 18 04...
Page 72: ...1 387 7 44 6 81 75 90 86 100 8 47 116 6 7 612 8 06 8 526 101 213 8 1 245 1 296 1 348 6 42 8 77 74 86 31 95 74 48 118 4 7 328 7 754 8 196 102 215 6 1 209 1 258 1 309 5 41 73 94 82 01 90 88 49 120 2 7 0...