IAI ssel First Step Manual Download Page 1

   

 

SSEL 

First Step Guide     

First Edition

 

 
Thank you very much for purchasing our product. 
Make sure to read the detailed Operation Manual (CD) included with the product 
in addition to this First Step Guide to ensure correct use. 

 

 

Product Check 

 

This product is comprised of the following parts if it is of standard configuration: 

1.  Parts (The option is excluded.) 

No. Part 

Name 

Model 

1 Controller 

Refer to “How to understand the Model Name Plate” and 
“How to understand the Model No.” 

Accessories 

2 I

 I/O Flat cable 

CB-DS-PIO***    ***indicates the cable length 

Battery for saving 
Absolute Data

 *1

 

AB-5 

AC Power Supply plug 

MSTB2.5/6-STF-5.0 (Maker : PHOENIX CONTACT) 

System I/O plug (2 Units)  FMC1.5/4-ST-3.5 

First Step Guide 

 

Operation Manual (CD) 

 

8 Safety 

Guide 

 

*1: It is attached when the unit is absolute type.

 

 

2. Teaching Tool (Option) 

The personal computer application software or teaching pendant is required for 

the operations including program creation and setup such as position setting and 

parameter setting with teaching. Use either of them. 

No. Part 

Name 

Model 

PC Software 

(with RS232C Cable +Emergency Stop Box+ Connector conversion adapter )

  IA-101-X-MW-J 

PC Software (USB Cable with a dummy plug) 

IA-101-X-USB 

3 Teaching 

pendant 

SEL-T 

Teaching pendant (with deadman switch) 

SEL-TD 

Wall Hanging Hook specially for SEL-T/TD 

HK-1 

Strap specially for SEL-T/TD 

STR-1 

7 Teaching 

pendant 

IA-T-X 

Teaching pendant (with deadman switch) 

IA-T-XD 

9 Panel 

Unit 

*2

 PU-1 

*2: It is the unit specially for “Status” indication.

 

3.  Operation manuals related to this product, which are contained in the CD. 

No. Name 

Catalog 

No. 

1 SSEL

 Controller Operation Manual 

MJ0157 

2  PC Software  IA-101-X-MW/ IA-101-X-USBMW 

MJ0154 

3  Teaching pendant  SEL-T/TD 

MJ0183 

4  Teaching pendant  IA-T-X/XD 

MJ0160 

5 DeviceNet

 Operation Manual 

MJ0124 

6 CC-Link

 Operation Manual 

MJ0123 

7 ProfiBus-DP

 Operation Manual 

MJ0153 

 
 
 

4.  How to read the model plate 

 

 

 
 
 

5.  How to read the model of the controller 

[SSEL] 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Basic Specifications 

SSEL  Specifications 

Specification Item 

Single-Axis Type 

Double-Axis Type 

AC100V Specification 400W 

Max. Connected 
Axis Output 

AC200V Specification 800W 
AC100V Specification Single-phase 100V to 115V ± 10% 

Control Power 
Source Voltage 

AC200V Specification Single-phase 200V to 230V ± 10% 
AC100V Specification Single-phase 100V to 115V ± 10% 

Motor Power Source 
Voltage 

AC200V Specification Single-phase 200V to 230V ± 10% 

Power frequency 

50/60Hz 

Load Current 

*1

 

55A (Control)    55A (Driving) 

55A (Control)    110A (Driving) 

Leakage Current 

*2

 

1.0mA or less 

Power Capacity for Electro-magnetic Brake Power Unit

 *3

(In the case of the actuator with a brake) 

DC24V 

±

 10%  Rated 0.5A  MAX 1A DC24V 

±

 10%  Rated 1A  MAX 2A 

Heating Value for Electro-magnetic Brake Power Unit
(In the case of the actuator with a brake) 

12W 24W 

Momentary Power Interruption Tolerance

50Hz

10msec

60Hz

8msec 

Insulation Resistance 

DC500V  100M

 or more 

Insulation Strength 

AC1500V      for 1min. (actuator the time of connection 1000V AC for 1min.) 

Axis Control System 

AC Full 

digital Servo 

Position detection method 

Incremental Encoder or Absolute Encoder 
For Absolute Data Backup : Manufactured by our company AB-5 (Option) 

Battery for Backup 

For System Memory Backup : Manufactured by our company AB-5 (Option) 

Program language 

Super SEL language 

Max. Number of program steps 

9999 steps 

Max. Number of position 

20000 positions 

Max. Number of programs 

128 programs 

Max. Number of multitask programs 

8 programs 

Data storage device 

Flash ROM + SRAM Backup (Option) 

Data storage method 

Teaching pendant or PC software 

I/O Interface 

24 Input Points (Total of Dedicated Input  Universal Input Points) 
8 Output Points (Total of Dedicated Output  Universal Output Points) 

PIO Interface Power Supply 

DC24V 

±

 10% (Externally supplied) 

Teaching Port RS232C (Special Protocol) 26-pin Half Pitch I/O Connector (For connecting 1.27mm-pitch PCB Cable Pair

TX20A-26R-D2LT1-A1LHE  Manufactured by JAE) 

USB Teaching Port for connecting the PC

 

(Special Protocol) 

USB B Connector (XM7B-0442) For connecting the PC 

RS232C 

15m or less 

Communication 
cable length 

USB 5m 

or 

less 

System I/O 

Emergency-stop input, safety gate input 

Protective functions 

Overvoltage, motor over current, motor overload, driver temperature abnormality, and Encoder 
abnormality etc. 

Drive-source cutoff method 

Internal Relay 

Regenerative Resistance 

Built-in 20W Power Source (External Expansion Available) 

Surrounding air temperature 

0 to +40

°

Surrounding humidity 

10% to 95%RH (non-condensing) 

Surrounding environment 

There should not be any corrosive gas. In particular, there should not be much dust accumulation.

Surrounding storage temperature -25 to 70 degrees (However, except for battery (option)) 
Surrounding storage humidity

10% to 95%RH (non-condensing)

 

Vibration strength 

XYZ directions 10 to 57Hz

 

Pulsating amplitude 0.035mm (continuous) 0.075mm (intermittent)

57 to 150Hz    4.9m/s

2

 (continuous)  9.8m/s

2

 (intermittent) 

Environ-
ment 

Impact 

147mm/s

2

, 11ms    Semi-sine wave pulse three times to each of the directions X, Y and Z

Protection class 

IP20 

Cooling method 

Forced air-cooling 

Weight 1380g 
External dimensions 

(Refer to the Item for the External dimensions Dimension) 

 
*1  Rush current at the power connection continues for about 5 msec.

 Consider the safety 

rate at the time when rush current passes.

 The rush current value varies depending on 

the impedance of the power line. 

*2  The leaked current value is for the single controller not connected to the actuator. 
 

The leaked current varies depending on the surrounding environment. 

 

When the leakage protective measure is taken, measure the leakage current at the 
leakage breaker installation location. 

*3  The brake is an instantaneous over excitation brake. Current of max. 1A per axis 

passes during 100msec of brake release. 

 

Table 1: Motor Power Unit Capacity and Heating Value 

Actuator or   

Motor Capacity [W] 

Rated Motor   

Power Capacity [VA]

Momentary Maximum 

Motor Power Capacity

[VA] 

Heating Value in 

reaching the rated 

motor power capacity 

[W] 

20 26 

78 

1.6 

30 46 

138 

2.1 

60 138 

415 

3.9 

100 234 

701 

6.1 

150 328 

984 

8.3 

200 421 

1263 

9.1 

400 796 

2388 

19.8 

600 

1164 3492 27.2 

750 1521 

4564 

29.8 

100(Linear Actuator S6SS) 

101 303 3.7 

100(Linear Actuator S8SS) 

159 477 4.1 

100(Linear Actuator S8HS) 

216 648 3.8 

200(Linear Actuator S10SS) 

343 1029 5.3 

200(Linear Actuator S10HS) 

417 1251 5.0 

200(Linear Actuator H8SS) 

189 567 5.4 

200(Linear Actuator H8HS) 

379 1137 5.4 

200(Linear Actuator L15SS) 

189 567 5.4 

300(Linear Actuator M19SS) 

662 1986 11.6 

400(Linear Actuator W21SS) 

920 2760 16.7 

 

Table 2: Control Power Unit Capacity and Heating Value 

Control Power Capacity [VA] 

Control Power Unit Heating Value [W]

60 36 

 

[Power Capacity and Heating Value] 

Rated Power Capacity [VA] = First Axis Momentary Maximum Motor Power Capacity [VA]

*1

 + Second Axis 

Momentary Maximum Motor Power Capacity [VA]

*1

 + Control Power Capacity 

[VA]

*2

 

 

Momentary Maximum Power Capacity [VA] = First Axis Momentary Maximum Motor Power Capacity [VA]

*3

 + 

Second Axis Momentary Maximum Motor Power Capacity [VA]

*3

 

+ Control Power Capacity [VA]

*1

 

 

Heating Value in reaching the Rated Capacity [W] =  First Axis Motor Power Unit Heating Value in reaching 

the Rated Capacity [W]

*4

 + Second Axis Motor Power 

Unit Heating Value in reaching the Rated Capacity [W]

*4

 

+ Control Power Unit Heating Value [W]

*5

 

 

*1  Select the Rated Motor Power Capacity from Table 1. 
*2  Select the Control Power Capacity from Table 2. 
*3  Select the Momentary Maximum Motor Power Capacity from Table 1. 
*4  Select the Motor Power Unit Heating Value in reaching the Rated Capacity from Table 1 
*5  Select the Control Power Unit Heating Value from Table 2. 

 
 
 

SSEL – C 

  2 

 200A 

 100AB 

 NP 

  2 

  0 

X

 

Y

 

Z

 

[

 

[

 

\

 

]

 

^

 

  Model table 

[

 

Details of axis 1 to axis 2

 

X

 

Series

 

Y

 

Controller 

Type

 

Z

 

Number 

of axes 

Motor

Output

Encoder

 Type

Brake

Creep

Home 

Sensor

Synchro-

nization 
Desig-

nation

\

 

Standard 

I/O

 

]

 

I/O Flat 

cable 

length

_

 

Power-

supply 

voltage

SSEL 

(Standard 

Type) 

(1-axis) 

 

(2-axis) 

30D 

(30W for 

RCS2) 

30R 

(30W for 

RC) 

60 

(60W)

100 

(100W)

150 

(150W)

200 

(200W)

300 

(300W)

400 

(400W)

600 

(600W)

750 

(750W)

(Incre-

mental)

 

(Abso-

lute) 

Not 

Specified

(w/o 

brake)

 

(w/ brake)

Not 

Specified

(w/o 

creep)

 

(w/ 

creep)

Not 

Specified

(w/o home

 sensor)

 

(Applicable 

to Home 

Sensor LS)

Not 

Specified

  (No 

synchro-
nization)

 

(Master-

axis 

designation)

 

(Slave-axis
designation)

NP 

Standard PIO 

Input 24/

 

Output 8 

NPN type 

 

PN 

Standard PIO

Input 24/ 
Output 8 

PNP type 

 

DV 

DeviceNet 

CC 

CC-Link 

PR 

ProfiBus 

2 : 2m 

(Standard)

 
3 : 3m 
 
5 : 5m 

 

0 : None

1 : 

Single-phase

100V 

 

2 :   

Single-phase

200V 

MODEL      SSEL-C-2-200A-100AB-NP-2-1 
SERIAL No. 600061190 

MADE IN JAPAN 

Model

Serial number

Reviews: