Loadcell (Dedicated Option for SCON-CA)
This is the pressing force measurement unit that is used for the force control.
This is used by connecting to the actuator corresponding to the force control.
[Specification]
Item Specification
Loadcell System
Strain Gauge
Rated Capacity
20000N
Allowable Overload
200%R.C
*1
Loadcell Accuracy
±
1%R.C
*1
Zero
±
0.2%R.C/10
°
C
Temperature Drift
Output
±
0.1%R.C/10
°
C
Applicable Temperature Range
0 to 40
°
C
*1 R.C.: Rated Capacity
[Refer to RCS2-RA13R Instruction Manual for details of how to attach and the dimensions.]
Installation Environment, Storage Environment
This product is capable for use in the environment of pollution degree 2
*1
or equivalent.
*1 Pollution Degree 2: Environment that may cause non-conductive pollution or transient conductive
pollution by frost (IEC60664-1)
1. Installation Environment
Do not use this product in the following environment
•
Location where the surrounding air temperature exceeds the range of 0 to 40
°
C
•
Location where condensation occurs due to abrupt temperature changes
•
Location where relative humidity exceeds 85%RH
•
Location exposed to corrosive gases or combustible gases
•
Location exposed to significant amount of dust, salt or iron powder
•
Location subject to direct vibration or impact
•
Location exposed to direct sunlight
•
Location where the product may come in contact with water, oil or chemical droplets
•
Environment that blocks the air vent [Refer to Installation and Noise Elimination]
When using the product in any of the locations specified below, provide a sufficient shield.
•
Location subject to electrostatic noise
•
Location where high electrical or magnetic field is present
•
Location with the mains or power lines passing nearby
2. Storage and Preservation Environment
The storage and preservation environment should comply with the same standards as those for the
installation environment. In particular, when the machine is to be stored for a long time, pay close
attention to environmental conditions so that no condensation forms. Unless specially specified,
moisture absorbency protection is not included in the package when the machine is delivered. In
the case that the machine is to be stored and preserved in an environment where condensation is
anticipated, take the condensation preventive measures from outside of the entire package, or
directly after opening the package.
Installation and Noise Elimination
1. Noise Elimination Grounding (Frame Ground)
2. Precautions regarding wiring method
1) Wire is to be twisted for the 24V DC power supply.
2) Separate the signal and encoder lines from the power
supply and power lines.
3. Noise Sources and Elimination
Carry out noise elimination measures for power devices on
the same power path and in the same equipment.
The following are examples of measures to eliminate noise
sources.
1) AC solenoid valves, magnet switches and relays
[Measure] Install a Surge absorber parallel with the coil.
2) DC solenoid valves, magnet switches and relays
[Measure] Mount the windings and diodes in parallel.
Select a diode built-in type for the DC relay
4. Heat Radiation and Installation
Design and Build the system considering the size of the controller box, location of the controller and
cooling factors to keep the ambient temperature around the controller below 40
°
C
Connection Diagram
●
Standard
●
For Models Equipped with brake Except for RCS2-RA13R and NS Actuators
●
RSC2-RA13R Equipped with Brake, with no Loadcell, or NS Actuators with Brake
●
RCS2-RA13R Equipped with no Brake, with Loadcell in SCON-CA
●
RCS2-RA13R Equipped with Brake and Loadcell in SCON-CA
Power Supply and Emergency Stop Circuit
●
Wiring for Power Supply (to be prepared by customer)
Power consumption of SCON varies depending on the connected actuator, etc. Select the circuit breaker that suits to the
specification.
[Refer to Basic Specifications]
A ground fault circuit interrupter needs to be selected carefully considering the purposes of prevention of fire and protection
of human.
Have a measurement of the leak current where a ground fault circuit interrupter is to be installed.
Use the “harmonic type” for the ground fault circuit interrupter.
*1 CLF : Clamp Filter … It is recommended to attach it to improve noise immunity.
*2 SK : Surge Killer … It is recommended to attach it to improve noise immunity.
*3 NF : Noise Filter … Make sure to install it. It is recommended to have it installed within 0.3m of the cable length from
SCON.
Parts Name
Supplier
Model
CLF Clamp
Filter
TDK
ZCAT3035-1330
SK
Surge Protector
Okaya ELECTRIC CO.,LTD
R·A·V-781BWZ-2A
SOSHIN ELECTRIC CO.,LTD
NF2010A-UP
NF Noise
Filter
DENSEI-LAMBDA MC1210
●
Wiring for Emergency Stop Input
The following diagram shows an example of how the emergency stop switch for the teaching pendant may be
included in the emergency stop circuit you may construct.
Note 1 When the teaching pendant is not connected, S1 and S2 become short-circuited inside the controller.
Note 2 Connect a contactor to L1 and L2 terminals for external power cutoff by the emergency stop if the motor power is
required to be cut off externally to comply with the Safety Categories.
Note 3 The rating for the emergency stop signal to turn ON/OFF at contact CR1 is 24V DC and 10mA.
Note 4 For CR1, select the one with coil current 0.1A or less.
Attached to RCS2-RA13R
Loadcell
Regenerative Resistor Unit
(REU-2 : option)
Required depending
on usage condition
LED Indication
Axis Number
Setting Switch
Pulse Train Mode
Changeover Switch
System
I/O Connector
CB-SC-REU010
CB-ST-REU010
Regenerative Resistor Unit
(REU-1 [for secondary unit] : option)
Power Supply
Connector
FG Connection
Terminal
Absolute Battery
(for Absolute Type)
Mode Changeover Switch
Brake Release Switch
Brake Power Supply Connector
AK-04 (option)
Converts PLC open
collector output into
differential pulse output
JM-08 (option)
Converts SCON differential
pulse output into open
collector output
Flat Cable
(Accessories)
PLC
(Please prepare separately)
Touch panel teaching (option),
or Teaching pendant (option)
PC Software (option)
Detail View of Pulse Train Mode Changeover Switch
Pulse Train Mode Changeover Switch No. 1
ON: to select Pulse Train Control Mode
OFF: to select Positioner Mode
Actuator
The following models are excluded:
•
RCS2-RA13R with brake or loadcell equipped
•
NS Actuators with brake equipped
AK-04
JM-08
Wiring for Pulse
Train Control Mode
SW
ADRS
1 2
ON
↓
CB-RCS2-PLLA
RCS2-RA13R
(with Loadcel)
Absolute Battery
(for Absolute Type)
24V DC
Power Supply for Brake
Absolute Battery
(for Absolute Type)
Actuator
The following models are excluded:
•
RCS2-RA13R with brake or loadcell equipped
•
NS Actuators with brake equipped
24V DC
Power Supply for Brake
For LS (option)
Brake Box
CB-RCS2-PLA010
(enclosed to Brake Box)
For LS (option)
•
NS Actuators (with Brake
㧕
•
RCS2-RA13R (with Brake
㧕
Connect to back side
Absolute Battery
(for Absolute Type)
CB-LDC-LTL
CB-RCS2-PLLA
RCS2-RA13R
(with Loadcell and Brake)
CB-RCS2-PLA (enclosed to Brake Box)
24V DC
Brake Box
RCB-110-RA13-0
Connect to back side
Absolute Battery
(for Absolute Type)
Power Supply for Brake
100V AC
or
200V AC
(Refer to Controller
Power Voltage Specifications)
Circuit
Breaker
Ground Fault
Circuit
Interrupter
*3
NF
*2
SK
CLF
Class D grounding
(Formerly Class-III grounding)
+24V
0V
24V DC
Power
Supply
SCON
AC Power Supply
Input Connector
B. Motor Power Unit
A. Control power supply
L1
L2
L1C
L2C
NC
PE
BK+
PWR-
Brake Power Supply
Input Connector
PIO
Connector
Brake
Release Box
*1
10mm or more
50mm
or more
50mm
or more
50mm
or more
50mm
or more
50mm
or more
50mm
or more
100mm
or more
30mm
or more
10mm
or more
100mm
or more
150mm
or more
Air Flow
Air Flow
Fan
Brake Box
Regenerative
Resistor Unit
Place a fan to make the
ambient temperature even
Earth Terminal
Connect using FG connection
terminal on the main unit.
Copper Wire :
Connect to an ground cable with
diameter 1.6mm or more.
Controller
Class D grounding
(Formerly Class-III grounding :
Grounding resistance at 100
Ω
or less)
Do not share the ground wire with or connect
to other equipment. Ground each controller.
Controller
Other
equipment
Controller
Other
equipment
Other
equipment
Surge absorber
Relay
coil
Relay coil
R
C
+24V
0V
+24V
0V
+
-
24V
Emergency stop
reset switch
Emergency stop
switch
Emergency stop switch
for the teaching pendant
(Note 1)
SCON-CA
First unit
SCON
-CA
Second
unit
SCON
-CA
Nth unit
S1
S2
S1
S2 S1
S2
CR1
(Note 1)
0V
MC1
CR1
CR1
CR1
(Note 1)
MC1
(Note 2)
AC100V
AC200V
SCON-CA
EMG+
EMG-
L1
L2
L1C
L2C
24V
Motor power cutoff relay
Motor
power supply
Control
power supply
CR1
(Note 1)
MC1
(Note 2)
AC100V
AC200V
EMG+
EMG-
L1
L2
L1C
L2C
SCON-CA
Second unit
CR1
(Note 1)
MC1
(Note 2)
AC100V
AC200V
EMG+
EMG-
L1
L2
L1C
L2C
SCON-CA
Nth Unit