SCON
First Step Guide
Seventh Edition
Thank you for purchasing our product.
Make sure to read the Safety Guide and detailed Instruction Manual (DVD) included with the product in addition to
this First Step Guide to ensure correct use.
This Instruction Manual is original.
•
Using or copying all or part of this Instruction Manual without permission is prohibited.
•
The company names, names of products and trademarks of each company shown in the sentences are registered
trademarks.
Product Check
This product is comprised of the following parts if it is of standard configuration.
If you find any fault in the contained model or any missing parts, contact us or our distributor.
1. Parts
No. Part
Name
Model
Reference
1 Controller
Main
Body
Refer to “How to read the model plate”, “How to read the model”
Accessories
2
I/O Flat Cable
CB-PAC-PIO***
*** shows the cable
length
3
Service Connector for Pulse
Train Control
Plug : 10114-3000PE, Shell : 10314-52F0 (Supplier : 3M)
Enclosed in SCON-C/CA
4
System I/O Plug
FMC1.5/4-ST-3.5
(Supplier : Phoenix Contact)
5
Power Supply Plug for Brake MC1.5/2-ST-3.5
(Supplier : Phoenix Contact)
Applicable Cable Size
0.5mm
2
(AWG20)
6
AC Power Supply plug
MSTB2.5/6-STF-5.08
(Supplier : Phoenix Contact)
Applicable Cable Size
2.0mm
2
(AWG14)
7 Absolute
Battery
AB-5
Enclosed
in
Absolute
Type
8 Dummy
plug
DP-5
Enclosed
in
SCON-CGAL
9
First Step Guide
10 Instruction Manual (DVD)
11 Safety
Guide
2. Teaching Tool (to be purchased separately)
A teaching tool such as PC software is necessary when performing the setup for position setting, parameter
setting, etc. that can only be done on the teaching tool.
Please prepare either of the following teaching tools such as PC software.
No. Part
Name
Model
1
PC Software
(RCS232C converter adapter and external equipment communication cable are included)
RCM-101-MW
2
PC Software
(USB converter adapter, USB cable and external equipment communication cable are included)
RCM-101-USB
3
Touch Panel Teaching CON-PTA
CON-PTA
4
Touch Panel Teaching CON-PDA (Dead-man switch is included)
CON-PDA
5
Touch Panel Teaching CON-PGAS (Dead-man switch and TP adapter are included)
CON-PGAS
6 Touch
Panel
Teaching
TB-01
TB-01
7
Touch Panel Teaching TB-01 (with dead-man switch attached on the left)
TB-01D
8
Touch Panel Teaching TB-01 (with dead-man switch attached on the right)
TB-01DR
3. Instruction manuals related to this product, which are contained in the Instruction manual (DVD).
No. Name
Manual
No.
1
SCON Controller Instruction Manual
ME0161
2
SCON-CA/CAL/CGAL Controller Instruction Manual
ME0243
3
PC Software
RCM-101-MW/ RCM-101-USB Instruction Manual
ME0155
4
Touch Panel Teaching CON-PTA/PDA/PGAS Instruction Manual
ME0295
5
Touch Panel Teaching TB-01 Position Controller Instruction Manual
ME0324
4. How to read the model plate
5. How to read controller model
Basic Specifications
List of Specifications
SCON-C/CA
Item
Less than 400W
400W or more
SCON-CAL/CGAL
Corresponding Motor Capacity
12W to 399W
400W to 750W
12W to 200W
Power-supply Voltage
Single-Phase 100 to 115V AC
(Power fluctuation within
±
10%)
Single-Phase 200 to 230V AC
(Power fluctuation within
±
10%)
Single-Phase 200 to 230V AC
(Power fluctuation within
±
10%)
Single-Phase 100 to 115V AC
(Power fluctuation within
±
10%)
Single-Phase 200 to 230V AC
(Power fluctuation within
±
10%)
Power-supply Voltage 100V AC
Rush
Current
*1
Power-supply Voltage 200V AC
20A (Controller side), 70A
(Drive side)
20A (Controller side),
80A (Drive side)
30A (Controller side),
80A (Drive side)
Load Capacity
Refer to Power Capacity and Heat Generation
Leak Current
*2
3.0mA Primary side when noise filter is connected to power supply line
Heat Generation
Refer to Power Capacity and Heat Generation
Power Supply Frequency
50/60Hz
PIO Power Supply
*3
24V
DC
±
10%
Power Supply for Electromagnetic Brake
(for actuator equipped with brake)
24V DC
±
10% 1A (MAX.)
(supplied from external equipment)
SCON-C : 10ms (50Hz), 8ms (60Hz)
Transient Power Cutoff Durability
SCON-CA : 20ms (50Hz), 16ms (60Hz)
20ms (50Hz), 16ms (60Hz)
Motor Control System
Sine Wave PWM Vector Current Control
Corresponding Encoder
Incremental Serial Encoder, Absolute Serial Encoder,
ABZ (UVW) Parallel Encoder
Incremental Serial Encoder,
Absolute Serial Encoder,
Actuator Cable Length
MAX. 20m
Serial Communication Interface
RS485 : 1CH … based on Modbus Protocol RTU/ASCII
Speed : 9.6 to 230.4Kbps
Control available with serial communication in the modes other than the pulse train
PIO
Specifications
Signal I/O dedicated for 24V DC (selected from NPN/PNP) … Input 16 ports max.,
output 16 ports max.
External Interface
(Each dedicated
controller)
Fieldbus
Specification
DeviceNet/CC-Link/PROFIBUS/CompoNet*/MECHATR
OLINK*/EtherCAT*/EtherNET/IP*/PROFINET IO*
(*Specified only for SCON-CA)
DeviceNet/CC-Link/PROFIB
US/CompoNet/MECHATRO
LINK/EtherCAT/EtherNET/I
P/PROFINET IO
PIO MAX.
10m
RS485
Total cable length 100m or less.
Cable Length
Fieldbus
Refer to each Fieldbus specification
Data Setting and Input
PC Software, Touch Panel Teaching, Teaching Pendant
SCON-C : Saves position data and parameters to
non-volatile memory
(Limitation in number of writing 100,000 times)
Data Retention Memory
SCON-CA : Saves position data and parameters to
non-volatile memory
(There is no limitation in number of writing)
Saves position data and
parameters to non-volatile
memory
(There is no limitation in
number of writing)
Operation Mode
Positioner Mode/Pulse Train Control Mode
(selected by Pulse Train Mode Changeover Switch on
Front Panel)
Positioner Mode
Number of Positions in Positioner
Mode
Standard 64 points, maximum 512 points (PIO Type), 768 points (only for SCON-CA Fieldbus Type)
(Note) Number of positions differs depending on the selection in PIO pattern and fieldbus operation mode.
SCON-C : Differential System (Line Driver System) :
MAX. 500Kpps
SCON-CA : Differential System (Line Driver System) :
MAX. 2.5Mpps
Input Pulse Frequency
Common to C/CA : Open Collector Type :
200Kpps max. (under condition AK-04 is used)
Pulse Train
Control
Mode
(Dedicated
for PIO
Specifications)
Command Pulse
Multiplying Factor
(Electrical Gear : A/B)
1/50
<
A/B
<
50/1
Setting Range of A and B (set to parameter) : 1 to 4096
SCON-C :
Differential System (Line Driver System):
MAX. 500Kpps (Linear output available up to
109Kpps)
SCON-CA : Differential System (Line Driver System):
MAX. 2.5Mpps
Feedback Pulse
(Dedicated for PIO Specifications)
Common to C/CA : Open Collector Type:
MAX. 500Kpps (under condition JM-08 is used)
LED Display
(mounted on Front Panel)
PWR (green) : Controller in normal condition,
SV (green)
: Servo on,
ALM (orange) : Alarm generated,
EMG (red)
: Emergency Stop
PWR (green) : Controller in
normal condition / SV
(green) : Servo on / ALM
(orange) : Alarm generated /
EMG (red) : Emergency
Stop / WRG (orange) :
Warning generated
Electromagnetic Brake Compulsory Release
Switch (mounted on Front Panel)
Switching NOM (standard)/BK RLS (compulsory release)
Insulation Resistance
500V DC 10M
Ω
or more
Insulation Strength
1,500V AC for 1 min. (Note) Withstand voltage of force control loadcell is 50V DC
Surrounding air temperature 0 to 40
°
C
Surrounding humidity
85%RH or less (non-condensing)
Surrounding environment
[Refer to Installation Environment]
Surrounding storage temperature -20 to 70
°
C (non-condensing)
Surrounding storage humidity 85% or less (non-condensing)
Environment
Vibration Durability
XYZ Each direction 10 to 57Hz Pulsating amplitude 0.035mm (continuous) 0.075mm (intermittent)
57 to 150Hz 4.9m/s
2
(continuous) 9.8m/s
2
(intermittent)
Protection Class
IP20 or equivalent
Weight
SCON-C : Approx. 800g
SCON-CA : Approx. 900g
SCON-C : Approx. 1100g
SCON-CA : Approx. 1200g
Approx. 560g
Cooling Method
Natural air-cooling
Forced Air Cooling
Forced Air Cooling
External Dimensions
58W
×
194H
×
121D [mm] 72W
×
194H
×
121D [mm]
49W
×
158H
×
116D [mm]
*1 In-rush current will flow for approximately 20msec after the power is turned on (at 40
°
C).
Note that the value of in-rush current differs depending on the impedance of the power supply line.
*2 Leak current varies depending on the capacity of connected motor, cable length and the surrounding environment. Measure the
leak current at the point where a ground fault circuit interrupter is to be installed when leakage protection is conducted.
A ground fault circuit interrupter needs to be selected carefully considering the purposes of prevention of fire and
protection of human.
Use the harmonic type (for inverter) for the ground fault circuit interrupter.
*3 It is not necessary to supply power to PIO when operating with using ROBONET, Gateway Unit or SIO Converter
without using PIO. In this case, set the parameter No. 74 (PIO Power Supply Monitor) to “1” (Invalid). It will generate
the error code No. 0CF (I/O 24V Power Supply Error) if the setting is not done.
Power Capacity and Heat Generation
Rated Power Capacity
=
Motor Power Capacity
+
Control Power Capacity
Peek Max. Power Capacity
=
Peek Max. Motor Power Capacity
+
Control Power Capacity
Actuator Motor Type
Motor Power
Capacity
[VA]
Peek Max. Motor
Power Capacity
[VA]
Control Power
Capacity
[VA]
Rated Power
Capacity
[VA]
Peek Max. Power
Capacity [VA]
Heat Generation
[W]
12
41 123
89 171 30
30D (Excluding RS)
46
138
94
186
31
30R (for RS)
138
414
186
462
33
60 138
414
186
462
33
60 (RCS3-CTZ5)
197
591
245
639
32
100 234
702
282
750
35
100S (LSA)
283
851
331
899
36
150 328 984
376 1032 37
200 421
1263
469
1311
38
200S
(LSA excluding LSA-N15H)
486 1458
534 1506 38
200S
(LSA-N15H)
773 2319
821 2367 56
300S
(LSA) 662 1986
710 2034 40
400
920 2760
968 2808 45
400
(RCS3-CT8)
1230 3690
1278 3738 47
600 1164
2328
1212
2376
56
750 3042
3090
750S
1521
4563
48
1569
4611
58
RS : Rotary Shaft LSA : Linear Actuator
Selection of Circuit Interrupter
•
3 times of the rated current flows to the controller during the acceleration/deceleration. Select an interrupter that does not trip
with this value of current. If a trip occurs, select an interrupter that possesses the rated current of one grade higher. (Refer to
the operation characteristics curves in the product catalog.)
•
Select an interrupter that does not trip with the in-rush current. (Refer to the operation characteristics curves in the product
catalog.)
•
Consider the current that enables to cutoff the current even when a short circuit current is flown for the rated cutoff current.
Rated Interrupting Current
>
Short Circuit Current
=
Primary Power Capacity / Power Voltage
Consider margin for the rated current on the circuit breaker.
Rated Current for Circuit Interrupter
>
(Rated Motor Power Capacity [VA]
+
Control Power Capacity [VA]) /
AC Input Voltage
×
Safety Margin (reference 1.2 to 1.4 times)
External Dimensions
SCON-C/CA
Less than 400W
400W or more
SCON-CAL/CGAL
DIN Rail
(8.5)
35.4 (Width of 35mm DIN Rail )
* There is no DIN rail part on the type with screw attachment.
For DIN Rail
Mounting Type
82.5 from DIN rail center
130.7
116
4
49
158
(17)
For Screw-fixed Type
(6)
4.5
φ
4.5
22.5
(6)
146.5
Serial number
Model
SCON-CA-60A-NP-2-1
MODEL
SERIAL No.
800056144 L11
MADE IN JAPAN
S C O N - C A - 2 0 I H A - N P - 3 - 1 - D N - * *
<Series>
<Type>
C
: Standard Type
CA
: High Performance Type
CAL : Small Type
CGAL : Small Global Type
<Actuator Characteristics>
[Motor Type] * For SCON- CAL/CGAL, 200W or Less
12
: 12W
200 : 200W
20
: 20W
200S : 200W (LSA)
30D : 30W (Excluding RS) 300S : 300W (LSA)
30R : 30W (for RS)
400 : 400W
60
: 60W
600 : 600W
100 : 100W
750 : 750W
100S : 100W (LSA)
750S : Equipped with Loadcell
150 :
150W
RCS2-RA13R
<Encoder Type>
I : Incremental
A : Absolute
G : Spurious Absolute
(Note 3)
<Option>
No Indication : Standard Type
HA : High Acceleration/Deceleration Type
I : Index
Absolute
Type
(DD)
(Note 3)
M : Multi-Rotation Absolute Type (DD)
(Note 3)
<Identification for IAI use only>
* There is no identification in some cases.
< Type of Installation
(dedicated for SCON-CAL/CGAL) >
Not Specified : Screw Attachment Type
DN : DIN Rail Mounting Type
<Power-supply Voltage>
1 : Single-Phase 100V AC
2 : Single-Phase 200V AC
<I/O Cable Length>
0 : Equipped with no cable
2 : 2m
3 : 3m (Standard)
5 : 5m
121
min80
58
29
φ
4.2
184
194
(200.5)
5
4.2
Absolute Battery
(for Absolute Encoder Type)
72
43
φ
4.2
4.2
5
184
194
(200.5)
Absolute Battery
(for Absolute Encoder Type)
Side View (in common)
Warning : Operation of this equipment requires detailed installation and operation instructions which are
provided on the DVD Manual included in the box this device was packaged in. It should be retained
with this device at all times.
A hardcopy of the Manual can be requested by contacting your nearest IAI Sales Office listed at
the back cover of the Instruction Manual or on the First Step Guide.
<I/O Type>
NP : NPN Specification (Sink Type) (Standard) ML : MECHATROLINK Connection 1,2 Type
(Note 2)
PN : PNP Specification (Source Type)
ML3 : MECHATROLINK Connection 3 (Motion) Type
(Note 1)
DV : DeviceNet Connection Type
EC : EtherCAT Connection Type
(Note 2)
CC : CC-Link Connection Type
EP : EtherNet/IP Connection Type
(Note 2)
PR : PROFIBUS Connection Type
PRT : PROFINET-IO Connection Type
(Note 2)
CN : CompoNet Connection Type
(Note 2)
(Note 1) Specified only for SCON-CA (Note 2) Except for SCON-C (Note 3) Specified only for SCON-C/CA