![IAI ROBO Cylinder RCS2 Operating Manual Download Page 62](http://html1.mh-extra.com/html/iai/robo-cylinder-rcs2/robo-cylinder-rcs2_operating-manual_604041062.webp)
52
Home position
Z phase ON
position
Mechanical end
Approx. 2 mm
The countermark on the motor
aligns with this position.
Use Parameter home return offset distance (SCON) or home
preset value (SSEL and X-SEL) to specify the settings
(The values displayed above are factory default settings).
Example: Replacement motor (IAI encoder)
Coupling (with screws)
15.9 Replacing the Motor
15.9.1 Replacing the Motor of the Motor Straight Type (Coupling Type): SA4C, SA5C,
SA6C
[Items Required for Replacement]
Replacement motor
Coupling (with screws)
Allen wrenches
Phillips screwdriver
Scale
Oil-based marker pen
Grease
Other than cleanroom specification
Idemitsu Kosan
Daphne Eponex Grease No.2
Cleanroom specification
Kuroda Precision Industries
C Grease
• PC or teaching pendant
Caution: When replacing the motor, handle the replacement motor with due care. The actuator
has been shipped with the encode adjusted to an optimal position, so do not crush the
encoder unit. It may displace the encoder, thus impairing proper actuator operation.
[Overview of Replacement]
1) Move the slider to a position where Z phase turns on (home position) (2 mm from the mechanical end).
Replace the motor in this position.
2) Perform homing using a PC or teaching pendant and check for deviation from the initial home position.
If there is a deviation when the SCON controller is being used, use home return offset distance to
make the adjustments. If the SSEL or the X-SEL controller is being used, use home preset value to
make the adjustments.