IAI ROBO Cylinder RCP2 Series First Step Manual Download Page 5

2.  RCA, RCACR, RCAW Actuator 
[Connection to the ACON (other than ACON-CA, CB), ASEL controller] 

 
 
 
 
 
 
 
 

Dedicated Connection Cable 

 Motor Cable (Robot Cable)

  

CB-ACS-MA

□□□

 

 Encoder Cable  CB-ACS-PA

□□□

/Encoder Cable Robot Cable    CB-ACS-PA

□□□

-RB 

 

□□□

 shows the cable length. The max. length should be 20m.  Example) 080

=

8m 

[Connection to the ACON-CA, AMEC, ASEP controller, etc] 

 

 
 
 
 
 
 

 
Dedicated Connection Cable 

 Motor Encoder Cable    CB-ASEP2-MPA

□□□

 

 

□□□

 shows the cable length. The max. length should be 20m. 

 Example) 080

=

8m 

3.  RCS2, RCS2CR, RCS2W, RCS3, RCS3P, RCS3CR, RCS3PCR Actuator 
[Connection to the SCON, SSEL controller] 

 
 
 
 
 
 
 
 
 

Dedicated Connection Cable 

 Motor Cable  CB-RCC-MA

□□□

/Motor Cable Robot Cable    CB-RCC-MA

□□□

-RB 

 Encoder Cable  CB-RCS2-PA

□□□

/Encoder Cable Robot Cable    CB-X3-PA

□□□

 

 

□□□

 shows the cable length. The max. length should be 30m. 

 Example) 080

=

8m 

[Connection to the X-SEL controller] 

 
 
 
 
 
 
 
 
 
 

Dedicated Connection Cable 

 Motor Cable  CB-RCC-MA

□□□

/Motor Cable Robot Cable    CB-RCC-MA

□□□

-RB 

 Encoder Cable dedicated for XSEL-J/K types    CB-RCBC-PA

□□□

 

  /Encoder Cable Robot Cable dedicated for XSEL-J/K types    CB-RCBC-PA

□□□

-RB 

 Encoder Cable dedicated for XSEL-P/Q/R/S types    CB-RCS2-PA

□□□

 

  /Encoder Cable Robot Cable dedicated for XSEL-P/Q/R/S types    CB-X3-PA

□□□

 

 

□□□

 shows the cable length.   

The max. length should be 15m. The max. length for other cables is 20m. 

 Example) 080

=

8m 

[Connection to the RCS2-RA13R and SCON controller] 

 

Brake-Equipped Type 

 Non-Brake Type 

 
 
 
 
 
 
 
 
 

 Loadcell-Equipped Type (Option) 

 
 
 
 
 
 

 
 

[Prohibited Items in the Cable Processing] 

  Do not pull or bend forcibly the cable so as not to give any extra load or tension to the cable. 

  Do not process the cable for extension or shortening by means of cutting out, combination or connecting with another cable. 

 

 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

     Note: 

  When the cable is connected or disconnected, make sure to turn off the power to the controller. When the cable is connected 

or disconnected with the controller power turned ON, it might cause a malfunction of the actuator and result in a serious injury 
or damage to the machinery. 

  When the connector connection is not correct, it would be dangerous because of a malfunction of the actuator. Make sure to 

confirm that the connector is connected correctly. 

 

Head Office: 577-1 Obane Shimizu-KU Shizuoka City Shizuoka 424-0103, Japan

TEL +81-54-364-5105  FAX +81-54-364-2589

website: www.iai-robot.co.jp/

Ober der Röth 4, D-65824 Schwalbach am Taunus, Germany

TEL 06196-88950  FAX 06196-889524

SHANGHAI JIAHUA BUSINESS CENTER A8-303, 808, Hongqiao Rd. Shanghai 200030, China

TEL 021-6448-4753  FAX 021-6448-3992

website: www.iai-robot.com

Technical Support available in USA, Europe and China

Head Office: 2690 W. 237th Street, Torrance, CA 90505

TEL (310) 891-6015  FAX (310) 891-0815

Chicago Office: 110 East State Parkway, Schaumburg, IL 60173

TEL(847) 908-1400  FAX (847) 908-1399

TEL (678) 354-9470  FAX (678) 354-9471

website: www.intelligentactuator.com

Atlanta Office: 1220 Kennestone Circle, Suite 108, Marietta, GA 30066

825 PhairojKijja Tower 12th Floor, Bangna-Trad RD., Bangna, Bangna, Bangkok 10260, Thailand

TEL +66-2-361-4458  FAX +66-2-361-4456

 

 

 

Manual No.: ME3687-10A

Moptor Cable
(CB-RCC-MA***)

Encoder Cable
(CB-RCS2-PLA***)

SCON 400W or more

Actuator

Radius for Cable Bend
R=100mm or more (Fixed Use)

RCS2, RCS2CR, RCS2W
RCS3, RCS3P, RCS3CR, RCS3PCR

r
r

Dedicated Controller

SCON

SSEL

Dedicated Connection Cable
(Connect RCS2, RCS2CR, RCS2W
 RCS3, RCS3P, RCS3CR or RCS3PCR with the dedicated controller.)

Robot Cable
 r = 58mm or more (Movable Use)
Standard Cable
 r = 93mm or more (Fixed Use)

Use robot cables if the cables tend to move.

RCS2, RCS2CR, RCS2W
RCS3, RCS3P, RCS3CR, RCS3PCR

r
r

Dedicated Controller

XSEL

Dedicated Connection Cable
(Connect RCS2, RCS2CR, RCS2W
 RCS3, RCS3P, RCS3CR or RCS3PCR with the dedicated controller.)

Robot Cable
 r = 58mm or more (Movable Use)
Standard Cable
 r = 93mm or more (Fixed Use)

Use robot cables if the cables tend to move.

  Do not let the cable flex at a single point. 

 

Steel Strap
(Piano Wire)

Tie them up softly.

  Do not let the cable bend, kink or twist. 

 

 

  Do not pull the cable with a strong force. 

 

 

 

  Do not let the cable receive a turning force at a single 

point. 

 

 

  Do not pinch, drop a heavy object onto or cut the cable.

 

 

  When fixing the cable, provide a moderate slack and do 

not tension it too tight. 

 

Do not use spiral tube in any 
position where cables are bent 
frequently.

 

  Separate the I/O line, communication line and power 

line from each other. 
Arrange so that such lines are independently routed in 
the duct. 

 

Power Line

Duct

I/O Line
(Flat Cable, etc.)

Follow the instructions below when using a cable track. 

  If there is an indication to the cable for the space factor 

in a cable track, refer to the wiring instruction given by 
the supplier when storing the cable in the cable track.

  Avoid the cables to get twined or twisted in the cable 

track, and also to have the cables move freely and do 
not tie them up. (Avoid tension being applied when the 
cables are bent.) 
Do not pile up cables. It may cause faster abrasion of 
the sheaths or cable breakage. 

 

Dedicated Controller

RCA, RCACR, RCAW 

r = 68mm or more (Movable Use) 
r = 34mm or more (Fixed Use) 

Dedicated Connection Cable 
(Connect RCA, RCACR or RCAW with the dedicated controller.) 

ACON-CA, AMEC, ASEP, MSEP, ACON-CB, MCON

RCA, RCACR, RCAW 


Dedicated Controller
ACON (other than ACON-CA, CB)
ASEL

Dedicated Connection Cable 
(Connect RCA, RCACR or RCAW with the dedicated controller.) 

Robot Cable 
 r = 54mm or more (Movable Use) 
Standard Cable 
 r = 75mm or more (Fixed Use) 

Use robot cables if the cables tend to move. 

SCON 400W or more 

Motor Cable 
(CB-RCC-MA***) 

Encoder Cable
(CB-RCS2-PLA010)

Encoder Cable 
(CB-RCS2-PLA***) 

Actuator 

External Brake Connection Box 
(RCB-110-RA13-0) 

Radius for Cable Bend 
R=100mm or more (Fixed Use) 

Radius for Cable Bend 
R=100mm or more (Fixed Use) 

Motor Cable 
(CB-RCC-MA***) 

Cable inside Loadcell Pair 
(CB-LDC-CTL***) 

Encoder Cable 
(CB-RCS2-PLA***) 
(CB-X2-PLA***) 

Actuator 

SCON-CA 400W or more 

Encoder Cable
(CB-RCS2-PLLA010)