background image

   

 

Simple Teaching Pendant RCM-E 

Data Setter RCM-P 

First Step Guide

  First Edition

 

Thank you for purchasing our product. 
Make sure to read the Safety Guide and detailed Instruction Manual (CD) included with the product in addition to   
this First Step Guide to ensure correct use. 
This Instruction Manual is original. 
 

 

 

 

 

 

 Using or copying all or part of this Instruction Manual without permission is prohibited. 

 The company names, names of products and trademarks of each company shown in the sentences are registered 

trademarks.

 

 

Product Check

 

This product is comprised of the following parts if it is of standard configuration. 

If you find any fault in the contained model or any missing parts, contact us or our distributor. 

1.  Parts (The option is excluded.) 

2.  Instruction Manuals related to this product, which are contained in the Instruction Manuals (CD). 

3.  How to read the model plate 

 

 

 

 
 
 
4.  How to read the model 
 

 

 

 

 

 

 

 

 

 

 

 

List of Support Models 

Model No. 

Support Started Version

RCP V1.00 
RCS V1.00 

E-Con V1.30 

RCP2 V1.63 

ERC V1.63 

ERC2 V2.00 

PCON V2.00 
SCON V2.00 
ACON V2.00 

ROBONET V2.08 

 

 

Item Specification 

Surrounding Air 
Temperature & Humidity 

Temperature : 0 to 40°C 
Humidity : 

85

%

 RH or less (non-condensing) 

*RH relative humidity 

Surrounding Environment There should be no corrosive gas or extremely heavy dust. 
Weight 

RCM-E : 400g    RCM-P : 380g 

Cable Length 

5m 

 

  

 

RCM-E 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

RCM-P 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Always turn the PORT switch “OFF” first before connecting a controller having this switch.

 

After the connection is established, put the PORT switch back to the “ON” side.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1) LCD Screen 
2)  EMERGENCY STOP (Emergency Stop Push Button Switch) (RCM-E) 

This switch is a mushroom-shaped push-lock, turn-reset type switch. 
This switch is connected to the emergency stop signal line on the controller in a series. Pressing this 
switch will bring to the emergency stop status and shut down the power supply to the motor. 
(normally, closed: b contact). 
[For the emergency stop signal line and its status, refer to the “Controller Instruction Manual” for the one 
being connected.] 
To release the emergency stop, rotate this switch in the direction indicated with arrows. 

(Note) :  If multiple controllers are connected using link cables, the EMERGENCY STOP switch is 

enabled only for the axis of the controller which is connected to the Teaching Pendant. 

 

  :  For RCP2-CG (external shutoff relay mount type), ERC and ERC2 series, the EMERGENCY 

STOP is only available when an emergency stop circuit is constructed externally. Please make 
sure to narrowly read the Instruction Manual for the connected controller. 

3)  ESC  key 

•  To return to upper level window 

A few layers of nest are constructed for the operation of Simple Teaching Pendant. Pressing this key 
enables you to go back to the one step higher layer (upper level window). 

When you don’t understand the operation, undo the operation by pressing the    ESC    key. 

4)

 

 BEGIN/END  key 
•  To finish process and reconnect 

By pressing and holding this key for approx. 2.5sec or more, the screen switches to “Begin/End” 
window. In this window, it is able to have operations such as to finish the processes of Simple Teaching 
Pendant and Data Setter and to reconnect the axes. 

•  It is able to cancel the input conducted with numeral keys. 
•   You may clear error warning 

When an error occurs, a message for this error will appear at the very bottom of the display screen. 
Use this key to clear the error and to clear this message. 

5)  

     

     

     

    (Arrow) keys (RCM-E)     

     

     

 

 

(Arrow) keys (RCM-P) 

•  This is used for selection of the mode, the contents of data and changing position No. 

6)

 

 (Minus) key

 

•  Position Table Column: When you push this in an area such as positioning width which allows minus 

input, the key functions as the “-” (minus), and the rest as “.” (point). 
When you input either    0    or    -/.    in the beginning of the number, within the proper area, the key 
will automatically recognize it as 0. 

7) 

 to  9  (Numeral) keys

 

This key is used for numerical input. 

8)

 

 (Return) key 

This is used for data input and operation confirm. 

No. Part 

Name 

Model 

Reference 

Main Body 

Refer to “How to read the model 

plate”, “How to read the model” 

 

Accessories 

First Step Guide 

 

 

3 Instruction 

Manual 

(CD) 

 

 

4 Safety 

Guide 

 

 

No. Name 

Manual 

No. 

Simple Teaching Pendant RCM-E Instruction Manual 

ME0174 

ROBO Cylinder Data Setter RCM-P Instruction Manual 

ME0175 

ERC2 Actuator with Integrated Controller Instruction Manual 

<PIO type> 

ME0158 

ERC2 Actuator with Integrated Controller Instruction Manual 

<SIO type> 

ME0159 

5 PCON-C/CG/CF 

Controller Instruction Manual 

ME0170 

PCON-CY Controller Instruction Manual 

ME0156 

PCON-SE Controller Instruction Manual 

ME0163 

PCON-PL/PO Controller Instruction Manual 

ME0164 

ACON-C/CG Controller Instruction Manual 

ME0176 

10 

ACON-CY Controller Instruction Manual 

ME0167 

11 

ACON-SE Controller Instruction Manual 

ME0171 

12 

ACON-PL/PO Controller Instruction Manual 

ME0166 

13 

SCON Controller Instruction Manual 

ME0161 

14 

SCON-CA Controller Instruction Manual 

ME0243 

15 

ROBONET Instruction Manual 

ME0208 

16 

RCS Series ROBO Cylinder Controller RCS-C Type Instruction Manual 

ME0102 

17 

RCS Series ROBO Cylinder Controller RCS-E Type Instruction Manual 

ME0103 

18 

E-Con Controller Instruction Manual 

ME0122 

19 

RCP2 Series ROBO Cylinder Controller Instruction Manual 

ME0136 

20 

ERC Actuator with Integrated Controller Instruction Manual 

ME0137 

Support Models 

Basic Specifications 

External Dimensions 

Connection Diagram 

Operation Panel 

R C M - E - E N G  

<Model> 

RCM-E : Simple Teaching Pendant 

RCM-P  : ROBO Cylinder Data Setter 

 

<Option> 

 Unspecified 

: Indication 

in 

Japanese 

  ENG 

: Indication in English 

 

Model 

Serial number 

RCM-E

MODEL 

SERIAL No. 

900109943   A1

MADE IN JAPAN 

113

145

72

43

15

26

6

23.5

21

86

23

140

Warning :  Operation of this equipment requires detailed installation and operation instructions which are 

provided on the CD Manual included in the box this device was packaged in. It should be retained with 

this device at all times. 

 

A copy of the CD Manual can be requested by contacting your nearest IAI Sales Office listed at   

the back cover of the Instruction Manual or on the First Step Guide. 

Controller

RCM-E

RCM-P

RCM-E

RCM-P

1) LCD

4) BEGIN/END
    key

7) 

to 9

(Numeral)
keys

7) 

to 9

(Numeral)
keys

3)  ESC  key

6) 

8) 

(Minus) key

(Return) key

1) LCD

2) EMERGENCY STOP

5) 

(Arrow) keys

5) 

(Arrow)
keys

6) 

(Minus) key

8) 

(Return) key

3)  ESC  key

4) BEGIN/END
    key

Reviews: