![IAI RA3R Operating Manual Download Page 30](http://html1.mh-extra.com/html/iai/ra3r/ra3r_operating-manual_604009030.webp)
20
(7) Double-guide
type
Use the tapped holes in the bracket for installing an actuator of the double-guide type.
z
Applicable models: Double-guide type RGD3, RGD4
Type Tapped
hole
diameter
Tapped
depth
Tightening
torque
RA3 type
M5
8 mm
3.4 N-m
RA4 type
M5
8 mm
3.4 N-m
Tapped mounting hole
Bracket A
Bracket B