CC-Link Type
Check the instruction manuals for each Field Network master unit and mounted PLC for the details.
Connector
Name
CC-Link Connector
Cable
Side
SMSTB2.5/5-ST-5.08 AU
Enclosed in standard
package
Manufactured by
PHOENIX CONTACT
Controller
Side
MSTBA2.5/5-G-5.08AU
Pin No.
Signal Name
Contents
Applicable Cable
1
DA (BL)
Communications Line A
2
DB (WT)
Communications Line B
3
DG (YW)
Digital GND
4
SLD
Connect the shield of the shielded
cable (Connect the FG of the 5
pins and controller FG internally)
5
FG Frame
Ground
(Connect the SLD of the 4 pins
and controller FG internally)
CC-Link
Dedicated Cable
PROFIBUS-DP Type
Check the instruction manuals for each Field Network master unit and mounted PLC for the details.
Connector
Name
PROFIBUS-DP Connector
Cable
Side
D-sub 9-pin connector (Male)
Please prepare
separately
Controller
Side
D-sub 9-pin connector (Female)
Pin No.
Signal Name
Contents
Applicable Cable
1 NC
Unconnected
2 NC
Unconnected
3 B-Line
Communications Line B (RS485)
4 RTS
Request for Sending
5 GND
Signal GND (Insulated)
6 +5V
+5V Output (Insulated)
7 NC
Unconnected
8 A-Line
Communications Line A (RS485)
9 NC
Unconnected
PROFIBUS-DP
Dedicated Cable
(Type A : EN5017)
CompoNet Type
Check the instruction manuals for each Field Network master unit and mounted PLC for the details.
Connector
Name
CompoNet Connector
Cable Side
Connector that complies with CompoNet standards
Controller
Side
XW7D-PB4-R
Manufactured by
OMRON
Pin No.
Signal Name
Contents
Applicable Cable
1
BS+ (RD)
Communication Power
(Note 1)
2 BDH
(WT)
Signal Cable H Side
3 BDL
(BL)
Signal Cable L Side
4
BS- (BK)
Communication Power
Supply -
(Note 1)
CompoNet
Dedicated Cable
Note 1 It is unnecessary to supply the communication power. (Internal power source is used.)
If conducting multi power supply to other slave devices via communication cables,
there is no problem with connecting the power supply to BS+ and BS- terminals.
MECHATROLINK Type
Check the instruction manuals for each Field Network master unit and mounted PLC for the details.
Connector
Name
MECHATROLINK Connector
Cable Side
Connector that complies with MECHATROLINK standards
Controller
Side
DUSB-ARB82-T11A-FA
Manufactured by DDK
Pin No.
Signal Name
Contents
Applicable Cable
A1/B1 NC
Unconnected
A2/B2 /DATA
Signal Cable - Side
A3/B3 DATA
Signal Cable + Side
A4/B4 SH
Shield
MECHATROLINK
Dedicated Cable
EtherNet/IP Type
Check the instruction manuals for each Field Network master unit and mounted PLC for the details.
Connector Name
EtherNet/IP Connector
Cable Side
8P8C Modular Plug
Controller Side
8P8C Modular Jack
Pin No.
Signal Name
Contents
Applicable Cable
1 TD+
Sent data +
2 TD-
Sent data -
3
RD+
Received
data +
4 -
Not used
5 -
Not used
6
RD-
Received
data -
7
-
Not used
8 -
Not used
For EtherNet cable, use a straight
STP cable that possesses the
performance of Category 5e or
more.
EtherCAT® Type
Check the instruction manuals for each Field Network master unit and mounted PLC for the details.
Connector Name
EtherCAT® Connector
Cable Side
8P8C Modular Plug
Controller Side
8P8C Modular Jack
Pin No.
Signal Name
Contents
Applicable Cable
1 TD+
Sent data +
2 TD-
Sent data -
3
RD+
Received
data +
4 -
Not used
5 -
Not used
6
RD-
Received
data -
7
-
Not used
8 -
Not used
For EtherNet cable, use a straight
STP cable that possesses the
performance of Category 5e or
more.
BK (BS-)
BL (BDL)
RD (BS+)
WT (BDH)
Front view of
connector on
controller side
1
2
3
4
Master Unit
Switching Hub
Slave Device
EtherNet Straight Cable
Category 5e or more
Double shielded cable braided with aluminum foil
recommended
MSCON
EtherNet/IP Type
Master Unit
Slave Device
EtherNet Straight Cable
Category 5e or more
Double shielded cable braided with aluminum
foil recommended.
(Note) Terminal resistor is not required.
MSCON
EtherCAT® Type
WT (DB)
BL (DA)
Shield (SLD)
YW (DG)
1
2
3
4
5
Front view of
connector on
controller side
1
6
9
5
コントローラ側
コネクタ正面図
Front view of
connector on
controller side
MSCON
CC-Link Type
SLD and FG are internally connected.
Connect the terminal resistor if the unit is
placed at the end of the network.
The terminal resistor differs depending on the type
of the dedicated cable for CC-Link.
• Cable FANC-SBH··· 130
Ω
1/2W
(High Performance Cable
dedicated for CC-Link)
• Cable FANC-SB······ 110
Ω
1/2W
(CC-Link Dedicated Cable)
Class D grounding
(Formerly Class-III grounding:
Grounding resistance at 100
Ω
or less)
Master Unit
Slave Device
Terminal
Resistance
Terminal
Resistance
BS+
BDL
BDH
BS-
BS+
BDL
BDH
BS-
BS+
BDL
BDH
BS-
Master Unit
Slave Device
Terminal Resistance
121
Ω
MSCON
CompoNet Type
Connect the terminal
resistor if the unit is
placed at the end
of the network.
24V
Power Supply
Supply power separately to the slave devices
that requires the communication power supply.
It is not necessary to supply communication power,
however, there is no problem even if
communication power is supplied.
Front view of
connector on
controller side
B1
A1
A4
B4
4
3
2
1
4
3
2
1
4
3
2
1
A4
A3
A2
A1
B4
B3
B2
B1
Master Unit
Slave Device
MECHATROLINK
Cable
MECHATROLINK Cable
MSCON
MECHATROLINK Type
Terminal Resistance
JEPMC-W6022
Connect the terminal
resistor if the unit is
placed at the end
of the network.
130
Ω
SH
DATA
/DATA
NC
Connect shield to
connector shell
SH
DATA
/DATA
NC
SH
DATA
/DATA
NC
Connect shield to
connector shell
1
8
Front view of
connector on
controller side
8
1
8
1
Front view of
connector on
controller side
5 1
9 6
Cable
Shield
Red B Line (Positive side)
Green A Line (Negative side)