6. Installation
38
6.3 Installing the Load on the Slider
x
The slider has two types of threaded holes, so affix the load using these holes. The affixing method shall
conform to the method for installing the actuator.
x
Similarly when the slider is affixed and actuator is moved, install the slider using these threaded holes on
the slider.
x
The slider has two reamed holes. If repeatability is required after removal/re-installation, use positioning
pins. If squareness is required, use one positioning pin and make installation adjustment.
x
After removal/re-installation, repeatability can also be ensured by pushing the reference surface on the side
of the base.
x
Use high-tension bolts conforming to ISO 10.9 or higher.
x
When the threaded holes are used, determine the required thread length as specified below:
x
ISDB, ISPDB, ISDBCR, ISPDBCR
Depth of threaded hole > Thread engagement length > Nominal thread size x 1.8
x
SSPDACR
Depth of threaded hole > Thread engagement length > Nominal thread size
z
ISDB, ISPDB, ISDBCR, ISPDBCR
C
Slider reference surface
(top)
Thread B
Thread A
Reamed hole C