43
4. Wiring
4.1.3 Address
Assignment
If multiple axes are connected, a slave number must be assigned to each axis so that the host can recognize the
corresponding actuator.
Assign addresses in the setting screen of the teaching pendant or PC.
z
Overview of operation on the PC
[1] Open the main window
o
[2] Click
Setup (S)
o
[3] Bring the cursor to
Controller Setup (C)
o
[4] Bring
the cursor to
Assign Address (N)
and click the mouse
o
[5] Enter an appropriate number in the
address table.
z
Overview of operation on the teaching pendant RCM-T
[1] Open the User Adjustment screen
o
[2] Use the
T
key to bring the cursor to
Address No.
o
[3] Enter
an appropriate address and press the ENTER key
o
[4] Enter “2” under
Adjustment No.
and press the
ENTER key.
z
Overview of operation on the simple teaching pendant RCM-E
[1] Open the User Adjustment screen
o
[2] Press the ENTER key to open the screen showing
Address No.
o
[3] Enter an appropriate address and press the ENTER key
o
[4] Enter “2” under
Adjustment No.
and press the ENTER key.
Refer to the operation manual for your teaching pendant or PC software for the specific operating procedure.
Caution: In the actual process of assigning addresses, the teaching pendant or PC and the target
actuator must have a one-on-one link. Therefore, disconnect the communication cables
(SGA/SGB) from other axes to tentatively provide a condition where not more than one
axis is connected.