CV-M2000 series
13
b) Shutter
Nine exposure time settings are avaliable.
Note : Factory pre-set is OFF.
OFF
Selectable shutter
Flicker-less
Auto
1/60 sec. (NTSC), 1/50 sec. (PAL)
1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/10,000 sec.
1/100 sec. (NTSC), 1/120 sec. (PAL)
Shutter speed changes automatically.
(1/60 sec. to 1/10000 sec. (NTSC), 1/50 sec. to 1/10,000 sec.(PAL)
:
:
:
:
CAUTION
Under certain unique light conditions, the following may appear.
- Strong smear and/or blooming on highlighted objects.
- Noticeable flicker in the picture.
Auto (CCD iris)
The variable electronic shutter controls the exposure time of the CCD sensor, depending on the incoming
light level. When this mode is selected, manual iris lens can be used instead of an auto iris lens.
1.
2.
c) AGC (Auto gain control)
Note : Factory pre-set is AGC OFF.
OFF
ON
Manual
:
:
:
Gain is fixed at minimum 0 dB
AGC ON (-6 dB to +12 dB)
Manual gain (-6 dB to +12 dB)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com