background image

 

CM-080GE/CM-080GE-RA / CB-080GE/CB-080GE-RA

 

 

 

- 53 -

   

 

 

The features shown above will vary depending on the specific camera. 

 

11.3.   Examples of camera operation 

The following descriptions are based on GenICam SFNC 1.3. 

11.3.1   Generic cautions for operation 

1.  The parameters in the gray part of the control tool cannot be changed. 

2.  If the image size is changed, the acquisition should be stopped and parameters  

set for determining the size. 

11.3.2   Connection of camera(s) 

Connect camera(s) to Network. After establishing the connection, start the control  

tool. 

The model name connected to the Network is displayed with connecting icon. 

 

CB-080GE

 

 

When this icon is double-clicked, the camera can communicate with the camera 

control tool and the icon is changed. 

 

 

 

11.3.3   Camera setting level 
The setting level has three layers: beginner, expert and guru. Guru level includes the most 

sophisticated functions. 

 

 

 

Summary of Contents for cb-040ge

Page 1: ...CM 080GE CB 080GE CM 080GE RA CB 080GE RA Digital Monochrome Color Progressive Scan GigE Vision Camera Document Version Version 2 1 CMB 080GE_Ver 2 1_Feb2013 User s Manual ...

Page 2: ...ndard part 1 FCC This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructio...

Page 3: ...n Products known as China RoHS The table shows contained Hazardous Substances in this camera mark shows that the environment friendly use period of contained Hazardous Substances is 15 years 嶷勣廣吭並 嗤蕎 嗤墾麗嵎賜圷殆兆各式根楚燕 功象嶄鯖繁酎慌才忽佚連恢匍何〆窮徨佚連恢瞳麟半陣崙砿尖一隈〇 云恢瞳ゞ 嗤蕎 嗤 墾麗嵎賜圷殆兆各式根楚燕 泌和 桟隠聞喘豚 窮徨佚連恢瞳嶄根嗤議嗤蕎嗤墾麗嵎賜圷殆壓屎械聞喘議訳周和音氏窟伏翌 亶賜融延 窮徨佚連恢瞳喘薩聞喘乎窮徨佚連恢瞳音氏斤桟廠夛撹冢嶷麟半 賜斤児繁附 夏恢夛撹冢嶷鱒墾議豚 方忖仝15々葎豚 15定 ...

Page 4: ...n Products known as China RoHS The table shows contained Hazardous Substances in this camera mark shows that the environment friendly use period of contained Hazardous Substances is 15 years 嶷勣廣吭並 嗤蕎 嗤墾麗嵎賜圷殆兆各式根楚燕 功象嶄鯖繁酎慌才忽佚連恢匍何〆窮徨佚連恢瞳麟半陣崙砿尖一隈〇 云恢瞳ゞ 嗤蕎 嗤 墾麗嵎賜圷殆兆各式根楚燕 泌和 桟隠聞喘豚 窮徨佚連恢瞳嶄根嗤議嗤蕎嗤墾麗嵎賜圷殆壓屎械聞喘議訳周和音氏窟伏翌 亶賜融延 窮徨佚連恢瞳喘薩聞喘乎窮徨佚連恢瞳音氏斤桟廠夛撹冢嶷麟半 賜斤児繁附 夏恢夛撹冢嶷鱒墾議豚 方忖仝15々葎豚 15定 ...

Page 5: ...and outputs table 16 6 4 Configuring the GPIO module 17 6 4 1 Input Output Signal Selector 17 6 5 Examples of the pulse generator configuration 17 6 5 1 Setting screen of the pulse generator 17 6 5 2 GPIO Plus PWC shutter 18 6 5 3 Internal Trigger Generator 19 7 Image output signal 20 7 1 Output image 20 7 2 Vertical Binning CM 080GE CM 080GE RA only 20 7 3 Digital Video Output Bit Allocation 21 7...

Page 6: ...e select trigger 47 10 2 6 Delayed Readout Mode Pre Select 49 10 2 7 OB transfer Mode 50 10 2 8 Operation Mode and Functions matrix 51 11 JAI control tool 52 11 1 About GenICamTM SFNC1 3 52 11 2 JAI SDK Ver 1 3 52 11 3 Examples of camera operation 53 11 3 1 Generic cautions for operation 53 11 3 2 Connection of camera s 53 11 3 3 Camera setting level 53 11 4 Input and Output settings 54 11 4 1 Int...

Page 7: ...ision Association The purpose of the GenICam standard is to provide a common program interface for various machine vision cameras By using GenICam cameras from different manufactures can seamlessly connect in one platform For details about the GigE Vision standard please visit the AIA web site www machinevisiononline org and for GenICam the EMVA web site www genicam org JAI GigE Vision cameras com...

Page 8: ...lso comply with the GenICam standard and contains an internal XML files that is used to describe the functions features of the cameras For further information about GigE Vision standard please go to www machinevisiononline org and about GenICamTM please go to www emva org As an application programming interface JAI provides an SDK Software Development Kit This SDK includes GigEVision Filter Driver...

Page 9: ...ble exposure from 84μs to 33 ms in Full Frame scan Sequencer trigger mode for on the fly change of gain exposure and ROI Edge Pre select and Pulse width trigger mode LVAL synchronous asynchronous operation auto detect Auto iris lens video output allows a wider range of light Can be Selected by DIP switch GigE Vision Interface with 10 or 8 bit output Programmable GPIO with opto isolated inputs and ...

Page 10: ...ws located above and below the Ethernet connector Note 2 Mounting holes M3 depth 3 5mm for tripod mount plate Note 3 1 Note Rear protrusion on C mount lens must be less than 10 0mm 2 Note When a RJ 45 cable with thumbscrews is connected to the camera please do not excessively tighten screws by using a screw driver The RJ 45 receptacle on the camera might get damaged For security the strength to ti...

Page 11: ...e and below the Ethernet connector Note 2 Mounting holes M3 depth 3 5mm for tripod mount plate Note 3 1 Note Rear protrusion on C mount lens must be less than 10 0mm 2 Note When a RJ 45 cable with thumbscrews is connected to the camera please do not excessively tighten screws by using a screw driver The RJ 45 receptacle on the camera might get damaged For security the strength to tighten screws is...

Page 12: ... operating in Continuous mode Flashing green The camera is receiving external trigger Ethernet connector indicates Steady green 1000 Base T has been connected Flashing green 100 Base T has been connected Flashing amber Network active in communication Note When 10 Base T is connected the green is flashing However the video is not streamed through Ethernet Fig 3 Rear Panel POWER TRIG GigE ...

Page 13: ... distributor for details on recommended industrial RJ 45 connectors Fig 5 Gigabit Ethernet connector The digital output signals follow the Gigabit Ethernet interface using a RJ 45 conforming connector The following is pin assignment for the Gigabit Ethernet connector Pin No In Out Name 1 In Out MX1 DA 2 In Out MX1 DA 3 In Out MX2 DB 4 In Out MX3 DC 5 In Out MX3 DC 6 In Out MX2 DB 7 In Out MX4 DD 8...

Page 14: ...se Generator Setting 0 Start Point Counter 0 1 Length counter 0 Start Point Counter 0 2 for repeat End point counter 0 Counter 0 clear Pulse Generator Setting 1 Pulse Generator 1 Pulse Generator 1 18 19 Pulse Generator 2 Pulse Generator 3 14 15 Pulse Generator Setting 2 Pulse Generator Setting 3 Pulse Generator 2 20 bit Counter Pulse Generator 3 20 bit Counter Fig 6 GPIO block The input and output...

Page 15: ...red pulse width starting point and end point Fig 7 Generated pulse Setting example The following example shows the FVAL input to pulse generator The pulse generator creates the pulse using FVAL and the pulse is output through GPIO PORT 1 The pixel clock is 60MHz Pulse Generator 0 IN FVAL 0 1 2 3 1 99 100 101 102 103 2 1 Start Point 0 End Point 99 Length 102 Clock IN Clock Source Pixel Clock 60MHz ...

Page 16: ... JAI SDK 6 2 Optical Interface The control interface of the C3 GigE Vision camera series has opto isolated inputs and outputs providing galvanic separation between the camera s inputs outputs and peripheral equipment In addition to galvanic separation the opto isolated inputs and outputs can cope with a wide range of voltages the voltage range of inputs is 3 3V to 24V DC whereas outputs will handl...

Page 17: ...ne c tor hiros e 12 c onne c tor Use r sid e JAI C3_Series CAMER A sid e E XTE RN A L IN P U T 3 3V IN Fig 10 External Input Circuit OPT IN 1 and 2 6 2 2 Recommended External Output circuit diagram for customer hirose 12 connector Pin 8 and 10 hirose 12 connector Pin 7 and 9 OUT 270 5V to 24V User Power 2 User side Camera Inside From Camera Circuit EXTERNAL OUTPUT 12V 220 To Fig 11 External Output...

Page 18: ...inimum Output Pulse Width 20us Time Delay Rise TDR 0 5us 0 7us Rise Time RT 1 2us 3 0us Time Delay Fall TDF 1 5us 3 0us Fall Time FT 4 0us 7 0us Fig 12 Optical Interface Performance 6 3 Inputs and outputs table Output Port Trigger 0 Trigger 1 OPT OUT1 OPT OUT2 Time Stamp Reset Pulse Gen 0 Pulse Gen 1 Pulse Gen 2 Pulse Gen 3 Input Port LVAL IN DVAL IN FVAL IN EEN IN OPT IN 1 OPT IN 2 Soft Trigger 0...

Page 19: ...or Line selector This sets the input and output to the external equipment Line 3 through line 6 are already allocated as below Line source This sets which signal can be fed through selected output external or internal 6 5 Examples of the pulse generator configuration 6 5 1 Setting screen of the pulse generator ...

Page 20: ...ng Value 0 Pass through Length Counter 0 1000 Clocks Start point Counter 0 100 Clocks Repeat Count 0 1 End point Counter 0 775 Clocks Counter Clear 0 Rising Edge Trigger source pulse generator 0 LUT Cross point switch 12bit Counte Pulse Generator 2 20bit Counter Pulse Generator 1 20bit Counter Pulse Generator 0 20bit Counter LUT 12bit Pulse Generator 3 20bit Counter LVAL IN DVAL IN FVAL IN EEN IN ...

Page 21: ...ff Trigger source pulse generator 0 LUT C ro ss po in t s w itc h 12 b it C ou n te P u lse G e n e ra to r 2 2 0 b it C o u n te r P u lse G e n e ra to r 1 2 0 b it C o u n te r P u lse G e n e ra to r 0 2 0 b it C o u n te r LUT 12 b it P u lse G e n e ra to r 3 2 0 b it C o u n te r LVAL IN DVAL IN FVAL IN EEN IN OPT IN 1 OPT IN 2 Soft Trigger 0 Soft Trigger 1 Soft Trigger 2 Soft Trigger 3 Cro...

Page 22: ...black pixels in the image stream 7 2 Vertical Binning CM 080GE CM 080GE RA only The binning functions can be used to achieve higher frame rate or higher sensitivity The drawback is lower resolution Vertical binning is done by adding the charge from pixels in adjacent lines in the horizontal CCD register Fig 13 shows the binning principle Resolution and frame rate for all combinations are shown in ...

Page 23: ...als 100 video output Fig 17 Digital Output 7 3 1 Bit Allocation Pixel Format Pixel Type CM 080GE CM 080GE RA In the GigE Vision Interface GVSP GigE Vision Streaming Protocol is used for an application layer protocol relying on the UDP transport layer protocol It allows an application to receive image data image information and other information from a device In the monochrome camera CM 080GE CM 08...

Page 24: ...GE CB 080GE RA the following pixel types supported by GVSP are available With regard to the details of GVSP please refer GigE Vision Specification available from AIA www machinevisiononline org 7 3 2 1 GVSP_PIX_BAYGB8 BayerGB8 Odd Line 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 G0 B1 G2 Even Line 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 R0 G1 R2 7 3 2 2 GVSP_PIX_BAYGB10 BayerGB10 Odd L...

Page 25: ... BAYER GB 10 When these types are selected the output starts from 2nd line for all scanning 7 4 CB 080GE CB 080GE RA Bayer filter CB 080GE CB 080GE RA is a color camera based on a CCD sensor with a Bayer RGB color mosaic The color image reconstruction is done in the host PC The Color sequence in the video signal is the same for all scanning formats The line readout follows LVAL The first valid pix...

Page 26: ...0ck 42 074us 1ck 29 629629ns LVAL DATA OUT Valid data OB 1034ck 40ck 1074ck 346ck DVAL 1 032ck 2ck 16ck Fig 19 Horizontal timing 7 5 2 Vertical timing The FVAL period for normal continuous mode full scan is shown FULL FRAME READ OUT FRAME RATE L 30 08fps LVAL FVAL 1 2 3 776 777 778 1L DAVL 5L 6L 778L DATA OB OB 3L CCD Exposure EEN 790 Valid data Fig 20 Vertical timing for full scan ...

Page 27: ...nformation for the fixed partial scan settings 1 2 1 4 1 3 and 2 3 LVAL FVAL DAVL 5L DATA Valid data CCD Exposure EEN A B C Values for vertical timing in partial scan continuous mode Fig 21 Vertical timing for partial scanning AREA FVAL Low L A L B L C L Total line frame rate Start line End line 1 2 5 53 390 49 L 497 L 47 82 195 1 4 5 77 194 73 L 349 L 68 10 293 1 8 5 89 98 85 L 277 L 85 8 341 2 3...

Page 28: ...bines charge from two adjacent lines reducing the vertical resolution to half and at the same time increasing frame rate and sensitivity By activating this function the frame rate is increased to 49 14 fps This function is available only for CM 080GE CM 080GE RA Important Note Vertical Binning cannot be used together with the Partial Scanning 7 5 4 1 Horizontal Timing 1LVAL 1730ck 51 259us 1ck 29 ...

Page 29: ...nal is available at pin 4 of 12 pin Hirose connector It can be used for lens iris control in Continuous and RCT modes only The signal is taken from the CCD sensor and is output after the gain circuit The video output is without sync The signal is 0 7 V p p from 400 Ω AC coupled Fig 25 Video output circuit To get this signal the internal DIP switch must be set as follows The auto iris lens video ou...

Page 30: ...tiple cameras going through a switch and or a single path or when operating in a system with limited transmission bandwidth the Delayed Readout Mode and Inter Packet Delay functions can be useful 8 2 Equipment to configure the network system 8 2 1 PC The PC used should have the following performance or better 1 Recommended CPU Core2 Duo 2 4GHz or better Better than Core2 Extreme 2 Recommended memo...

Page 31: ...40GE and CB 140GE series conform to Gigabit Ethernet IEEE 802 3 not all combinations of network interface cards NICs and switches routers are suitable for use with the GigE Vision compliant camera JAI will endeavor to continuously verify these combinations in order to give users the widest choice of GigE components for their system design For details of the network settings please refer to the Get...

Page 32: ... rate The CM 140GE and CB 140GE sereis can support a maximum of 4040 byte packets provided the NIC being used has a Jumbo Frames function with a setting of a 4040 bytes or larger Caution Do not set the packet size larger than the maximum setting available in the NIC or switch to which the camera is connected Doing so will cause output to be blocked 8 3 4 Calculation of Data Transfer Rate In order ...

Page 33: ... x8x30 1000000 200 Mbit s 8 3 5 Simplified calculation Approximate value A simple way to calculate the approximate data transfer rate is the following Transfer data Image width pixel x Image Height pixel x depth per pixel depending on the pixel format x frame rate 1 000 000 convert to mega bit In the case of the CM 080GE with the full image and MONO8 pixel format The data transfer rate 1032 x 778 ...

Page 34: ...tely in order for the data not to overflow in the switching hub 8 4 2 Connecting a camera to each port of a multi port NIC This is the example for using a 4 port NIC The pair of the connecting camera and the NIC constructs one subnet As for the IP configuration it is appropriate to use the persistent IP In this case each camera can use the maximum 800Mbps bandwidth However the load for the interna...

Page 35: ...The packet delay should be set larger The data traffic is controlled by the buffer of the hub It is necessary to check the buffer value of the unit 8 4 3 2 If delayed readout is not used in trigger mode The packet delay should be set larger The data traffic is controlled by the buffer of the hub It is necessary to check the buffer value of the unit ...

Page 36: ... CB 080GE CB 080GE RA 34 8 4 3 3 If delayed readout is used The packet delay should be set smaller and the packet delay trigger controls the data traffic If the camera has a pulse generator it can control the data traffic ...

Page 37: ... are described in detail 9 2 Electronic Shutter In the GenICam SFNC interface the electronic shutter is set by Exposure time microseconds The traditional JAI method for shutter setting can also be used including JAI Shutter Mode JAI Preset Shutter JAI Exposure Time Raw and JAI Exposure Time us If setting is done using the SFNC method these settings are automatically reflected in the traditional JA...

Page 38: ...Normal Scan 85µs 33 238 μs 2 3 Partial Scan 85µs 24 951 μs 1 2 Partial Scan 85µs 20 912 μs 1 4 Partial Scan 85µs 14 685 μs 1 8 Partial Scan 85µs 11 656 μs V Binning Scan 103 µs 20 351 μs GPIO in combination with Pulse Width Trigger More precise exposure time can be obtained by using GPIO in combination with Pulse Width Trigger mode The clock generator and counter can be programmed in very fine inc...

Page 39: ...ation 1 2 3 1 In this period camera executes trigger at next LVAL prevents feed through noise 2 Avoid trigger at FVAL transition 1 LVAL period as the function may randomly switch between next LVAL and immediate 3 In this period camera executes trigger immediately no delay Ext trigger FVAL ...

Page 40: ...ntinuous By executing AcquisitionStart command the image can be output until AcqusitionStop Trigger is input Single Frame By executing AcquisitionStart command one frame of the image can be output and then the acquisition is stopped Trigger Selector This can be selected from FrameStart or TransferStart FrameStart The trigger pulse can take one frame capture TransferStart The trigger pulse can read...

Page 41: ... the exposure mode Timed The exposure is set in units of μ seconds or lines TriggerWidth The exposure is the same as the trigger width The CM 080GE and CB 080GE series have a JAI Acquisition and Trigger Control function which is the same as used for previous models and includes 7 types of exposure modes Acquisition and Trigger Control and JAI Acquisition and Trigger Control are linked to each othe...

Page 42: ...he exposure time can be set in the JAI Shutter Mode by selecting either lines or microseconds and the setting values are reflected in the same items of Acquisition and Trigger Control Other parameters such as trigger signal should be set in Acquisition and Trigger Control The following description uses JAI Acquisition and Trigger Control and the operation mode can be selected in JAI Exposure Mode ...

Page 43: ...lled exposure 4 Reset continuous trigger mode Pre selected exposure 5 Sequential Trigger Pre selected exposure 6 Delayed Readout Trigger Pre selected exposure 10 2 1 Continuous operation For applications not requiring asynchronous external trigger but where a continuous stream of images is required this mode should be used It possible to use a lens with video controlled iris in this mode For timin...

Page 44: ... 24 and figures 28 and 29 To use this mode Important notes on using this mode Trigger pulse 2 LVAL to 1 FVAL The following table shows minimum trigger interval in synchronous accumulation mode Full scan 793 L 2 3 partial 596 L 1 2 Partial 500 L 1 4 Partial 352 L 1 8 Partial 280 L 1 2 V Binning 400 L 1 In case of a synchronous mode the exposure time should be added to the above table 2 In order to ...

Page 45: ... is input during FVAL HIGH period automatically set to LVAL sync mode 2L to 3L Fig 28 Edge Pre select LVAL sync Timing 10 2 2 2 LVAL_async timing 5 776μ s 1μ s 1L min CCD Exposure EEN Exposure FAVL 2L 3L Full 86us to 133us Vbinnig 117us to 169us Trigger is input during FVAL LOW period automatically set to LVAL s SYNC mode EPS LVAL a SYNC Trigger to Fig 29 Edge Pre select LVAL async Timing ...

Page 46: ...through fig 24 and figures 30 and 31 To use this mode Important notes on using this mode Trigger pulse width 2LVAL to 2 seconds The following table shows minimum trigger interval in synchronous accumulation mode Full scan 793 L 2 3 Partial 596 L 1 2 Partial 500 L 1 4 Partial 352 L 1 8 Partial 280 L V Binning 400 L 1 In case of a synchronous mode the exposure time should be added to the above table...

Page 47: ...ng FVAL HIGH period automatically set at LVAL SYNC mode 2L 3L Full 86us to 133us Vbinnig 117us to 169us to Fig 28 Pulse width control LVAL sync 10 2 3 2 LVAL_async timing PWC LAVL ASYNC 5 776μ s 1μ s Trigger 2L min 1L CCD Exposure EEN Exposure FAVL Trigger is input during FVAL LOW period automatically set to LVAL a SYNC mode 2L 3L Full 86us to 133us Vbinnig 117us to 169us to Fig 29 Pulse Width con...

Page 48: ...r speed If no further trigger pulses are applied the camera will continue in normal mode and the video signal is not output The fast dump read out has the same effect as smearless read out Smear over highlight areas is reduced for the trigger frame The reset continuous trigger mode makes it possible to use triggering in conjunction with a lens with video controlled iris This mode is available only...

Page 49: ... with the preset sequence is output as described below Trigger Sequence operation Sequence 1 Sequence 2 Sequence 3 Sequence 4 Signals added to trigger can be selected by Trigger Source The camera will functions on the rising edge of the trigger and Negative or Positive should be determined accordingly For the sequence the following default settings are installed ID ROI Shutter Gain Width Height Of...

Page 50: ...1 4 Partial 1 8 Partial 1 2 V Binning 793 L 596 L 500 L 352 L 280 L 400 L The conditions for this table are that the shutter speed should be set the same for all sequences If the shutter speed is different the difference of exposure time should be added It is recommended to set the exposure time in the order from the shortest to the longer one Do not input the trigger just after the sequence is re...

Page 51: ...gE interface it allows the cameras to be read out in sequence preventing congestion The image data is not transmitted directly by the trigger 0 and it is stored in the memory located at Ethernet Interface By the falling edge of the soft trigger 1 the image data is output Exposure CCD output Store in the GigE memory Output from GigE Trigger 0 CCD Photodiode CCD Transfer gate GigE memery Ethernet ou...

Page 52: ...F OB Transfer Mode ON Normal Scan 1 1032 1 778 1 1032 1048 1 6 784 2 3 Partial Scan 1 1032 1 518 1 1032 1048 1 ます 518 1 2 Partial Scan 1 1624 1 390 1 1032 1048 1 390 1 4 Partial Scan 1 1624 1 194 1 1032 1048 1 ます 194 1 8 Partial Scan 1 1624 1 98 1 1032 1048 1 98 V Binning Scan 1 1624 1 389 1 1032 1048 1 ます 389 16 pixels for horizontal is added 16 pixels for horizontal is added 16 pixels for horizo...

Page 53: ...select EPS Yes Yes Yes Auto No 0x02 Pulse Width PWC Not applicable Yes Yes Auto No 0x03 Reset continuous RCT Yes Yes Yes a sync only Yes Note 2 0x09 Sequential Pre select PS Yes Yes Yes a sync only No 0x17 EPS Delayed Readout Yes Yes Yes Auto No 0x18 PWC Delayed Readout Not applicable Yes Yes Auto No Note 1 Vertical Binning is available for only CM 080GE CM 080GE RA Note 2 The Auto iris output is ...

Page 54: ...fication The latest version of JAI GigE Vision cameras comply with GenICam SFNC1 3 However JAI can offer the following options for customers who use older versions of GIgE Vision cameras JAI provides the following software 1 Version prior to SFNC 1 3 for older camera version 2 Downgrade to old version from the latest SFNC 1 3 version Please contact local sales representatives for the details 11 2 ...

Page 55: ... changed the acquisition should be stopped and parameters set for determining the size 11 3 2 Connection of camera s Connect camera s to Network After establishing the connection start the control tool The model name connected to the Network is displayed with connecting icon CB 080GE When this icon is double clicked the camera can communicate with the camera control tool and the icon is changed 11...

Page 56: ...2 Setting of input and output 11 4 2 1 How to assign the signal to Line This function decides which signal is assigned to Digital I O Line 1 to Line 8 The following is the example to set Line5 Opt In 1 In this case the line source is the signal connected to Opt In 1 The line format is automatically set to Opto Coupled The following is the example to set the output signal It selects the output sign...

Page 57: ...E RA 55 11 4 2 2 Selecting of Trigger Source The trigger signal is chosen by TriggerSource of TriggerSelector in Acquisition Control In the following example pulse generator 0 is selected as the trigger signal 11 4 3 Setting the image size ...

Page 58: ... the screen After the setting of capture is completed push StartAcquisiton button As for the details of each operation mode refer to 10 Operation Modes 11 4 5 How to look at XML file All features and registers of the camera are stored in the camera as an XML file This XML file is stored in the following folder My computer Local disk C Program files GenICam_V2 0 xml TransportLayers JAI 11 4 6 Featu...

Page 59: ...CM 080GE CM 080GE RA CB 080GE CB 080GE RA 57 11 4 7 Feature Properties Guru ...

Page 60: ...CM 080GE CM 080GE RA CB 080GE CB 080GE RA 58 ...

Page 61: ...CM 080GE CM 080GE RA CB 080GE CB 080GE RA 59 ...

Page 62: ...CM 080GE CM 080GE RA CB 080GE CB 080GE RA 60 ...

Page 63: ...ons 12 1 CM 080GE and CB 080GE GigE POWER TRIG Outsidesizetolerance F 0 3mm 44 29 C Mount 13 26 26 1 73 1 14 14 5 0 57 0 51 5 0 2 1 02 1 02 depth0 14 59 75 Serial No 6 M3depth3 5 depth0 14 FCC seal Caution seal 67 3 M3 depth3 5 5 0 2 2 64 2 95 2 32 Fig 33 CM 080GE CB 080GE outline ...

Page 64: ...ount 6 M3depth 3 5 3 M3depth 3 5 depth0 14 depth0 14 depth0 14 102 5 4 04 6 3 0 25 1 14 29 31 1 22 32 5 59 8 0 31 2 32 1 28 1 02 26 Ser i al No Caut i on seal 4 M3depth 3 5 1 02 1 28 2 64 0 57 1 73 0 20 5 0 31 1 02 67 32 5 8 14 5 44 26 26 Gig E PO W E R T RIG FCC seal in inch Fig 34 CM 080GE RA CB 080GE RA outline ...

Page 65: ...CM 080GE CM 080GE RA CB 080GE CB 080GE RA 63 13 Specifications 13 1 Spectral response Fig 35 Spectral response for CM 080GE CM 080GE RA Fig 36 Spectral response for CB 080GE CB 080GE RA R G B IR Filter ...

Page 66: ...V p p enabled by internal switch Gain Manual 3 to 24 dB 1 step 0 0358dB Synchronization Internal X tal GPIO Module Input output switch Clock Generator One Pulse Generators Four Configurable 14 in 9 out switch 12 bit counter based on 25MHz clock or Pixel clock 20 bit counter programmable for length start point stop point repeat Hardware Trigger modes Edge Pre Select Pulse Width Control RCT Frame De...

Page 67: ...t Rear protrusion on C mount lens must be less than 10 0mm Optical Low pass Filter Built in only for CB 080GE CB 080GE RA Dimensions CM CB 080GE 44 x 29 x 75 mm W x H x D excluding protrusion CM CB 080GE RA 44 x 29 x 102 5 mm W x H x D excluding protrusion Weight CM CB 080GE 125 g CM CB 080GE RA 155 g In order to get specified performance it is needed to have approx 30 minutes pre heating Note Abo...

Page 68: ...shipped without visible image sensor blemishes Over time some pixel defects can occur This does not have a practical effect on the operation of the camera These will show up as white spots blemishes Exposure to cosmic rays can cause blemishes to appear on the image sensor Please take care to avoid exposure to cosmic rays during transportation and storage It is recommended using sea shipment instea...

Page 69: ...e tripod mounting plate please use the provided screws 14 5 Exportation When exporting this product please follow the export regulation of your own country 14 6 References 1 This manual for CM 080GE CM 080GE RA CB 080GE CB 080GE RA can be downloaded from www jai com 2 Datasheet for CM 080GE CM 080GE RA CB 080GE CB 080GE RA can be downloaded from www jai com 3 Camera control software can be downloa...

Page 70: ...Sept 2009 1 2 Change the depth in chassis for screws from 4mm to 3 5mm and add caution Gain up from 12dB to 24dB Camera revision G and after Sensitivity is changed Add RCT trigger mode August 2011 2 0 Totally revised to conform with GenICam SFNC ver 1 3 February 2013 2 1 Change power source from 12V to 12V to 24V ...

Page 71: ... names mentioned in this manual are trademarks or registered trademarks of their respective owners JAI A S cannot be held responsible for any technical or typographical errors and reserves the right to make changes to products and documentation without prior notification Europe Middle East Africa Asia Pacific Americas Phone 45 4457 8888 Fax 45 4491 3252 Phone 81 45 440 0154 Fax 81 45 440 0166 Phon...

Reviews: