background image

   

 

PCON-CA/CFA/CB/CFB/CGB/CGFB, 

ACON-CA/CB/CGB, DCON-CA/CB/CGB 

First Step Guide    Seventh Edition 

 

Thank you for purchasing our product. 
Make sure to read the Safety Guide and detailed Instruction Manual (DVD) included with the product in addition to   
this First Step Guide to ensure correct use. This First Step Guide is original manual written by only this product. 
 
 
 
 
 

 Using or copying all or part of this Instruction Manual without permission is prohibited.

 

 The company names, names of products and trademarks of each company shown in the sentences are registered 

trademarks.

 

 

Product Check 

The standard configuration of this product is comprised of the following parts. 
If you find any fault with the product you have received, or any missing parts, contact us or our distributor. 
1. Parts 

No. 

Part Name 

Model 

Reference 

Controller Main Body 

Refer to “How to read the model plate”, 
“How to read the model of the controller” 

 

Accessories 

Field Network Connector 

MSTB2.5/5-STF-5.08AU (CC-Link)

 

MSTB2.5/5-STF-5.08AUM (DeviceNet) 

Prepare for separately except for CC, 
DV type. 

Power Connector 

FMC1.5/8-ST-3.5   
(Supplier : PHOENIX CONTACT) 

Recommended cable size AWG16 to 20 
(1.25 to 0.5mm

2

Dummy plug 

DP-5 

For the safety category compliant type

 

Absolute Battery (Option) 

AB-7 or SEP-ABU* 

If applicable for Simple Absolute Type 

Serial Absolute Battery (Option)  AB-5 

If applicable for Serial Absolute Type 
(for ACON only) 

First Step Guide 

 

 

Instruction Manual (DVD) 

 

 

Safety Guide 

 

 

2. Teaching Tool (to be purchased separately) 
A teaching tool, such as PC Software, is necessary when performing programming and commissioning, such 
as editing position data or parameters. 
Please utilise any of the following teaching tools. 
(Note) TB-01/01D/01DR are not applicable for CC-Link IE. 

No. 

Part Name 

Model 

PC Software 
(with RS232C converter adapter 

+

 external equipment communication cable) 

RCM-101-MW 

PC Software 
(with USB converter adapter 

+

 USB cable 

+

 external equipment communication cable) 

RCM-101-USB 

Touch Panel Teaching TB-01 (Standard / with Deadman Switch Attached on the Left/ Right side) 

TB-01/01D/01DR 

Touch Panel Teaching TB-02 (Standard / with Deadman Switch Attached) 

TB-02/02D 

Data Setter TB-03 

TB-03 

3. Instruction Manuals related to this product, which are contained in the Instruction Manual (DVD). 

No. 

Name 

Manual No. 

PCON-CA/CFA Controller Instruction Manual 

ME0289 

PCON-CB/CFB Controller Instruction Manual 

ME0342 

ACON-CA, DCON-CA Controller Instruction Manual 

ME0326 

ACON-CB Series Contoroller, DCON-CB Series Contoroller Instruction Manual 

ME0343 

PC Software 

RCM-101-MW/RCM-101-USB Instruction Manual 

ME0155 

Touch Panel Teaching 

TB-01/TB-02/TB-03 Position Controller Instruction Manual 

ME0324/ME0355/ME0376 

Instruction Manual for the Serial Communication [for Modbus] 

ME0162 

CC-Link Instruction Manual 

ME0254 

DeviceNet Instruction Manual 

ME0256 

10  PROFIBUS-DP Instruction Manual 

ME0258 

11  CompoNet Instruction Manual 

ME0220 

12  MECHATROLINK-

/

 Instruction Manual 

ME0221 

13  MECHATROLINK-

  Instruction Manual 

ME0317 

14  EtherCAT Instruction Manual 

ME0273 

15  EtherNet/IP Instruction Manual 

ME0278 

16  PROFINET-IO Instruction Manual 

ME0333 

17  MECHATROLINK-

  Instruction Manual 

ME0317 

18  CC-Link IE Instruction Manual 

ME0389 

4. How to read the model plate 

 
 
 
 

 
 

5.  How to read the model of the controller 
 

z

 PCON 

P C O N - C A - 5 6 P   W A I - E P - 2 - 0 - A B U - D N - * *  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 

z

 ACON 

A C O N - C A - 3 0   I - E C - 2 - 0 - A B - D N - * *  

 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

z

 DCON 

D C O N - C A - 3   I - E P - 2 - 0 - D N - * *  

 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

Basic Specifications 

PCON List of Specifications 

Description 

Item 

PCON-CA/CB/CGB 

PCON-CFA/CFB/CGFB 

Number of controlled axes 

1-axis 

Power-supply Voltage 

24V DC 

±

10% 

20P, 28P, 28SP  MAX. 1A 

 

35P, 42P, 56P  MAX. 2.2A 

 

RCP2 

RCP3 

Motor 

Type 

60P, 86P 

 

MAX. 6A 

High-thrust function 

is disabled 

MAX.2.2A 

 

28P, 35P, 42P, 

56P 

High-thrust function 

is enabled   

Rated 3.5A / 

MAX. 4.2A 

 

Load 

Capacity

(including 

control side 

current 

consumption)

(Note1)

 

RCP4 

RCP5 

RCP6 

Motor 

Type 

56SP, 60P, 86P   

MAX. 6A 

Power Supply for Electromagnetic Brake 

(for actuator equipped with brake) 

24V DC 

±

10%    0.15A (MAX.) 

RCP2 , RCP3 

5W 

26.4W 

Heat Generation 

RCP4 to RCP6 

3W 

 

Rush Current 

(Note2)

 

8.3A 

10A 

Transient Power Cutoff Durability 

MAX. 500

μ

Motor Control System 

Weak field-magnet vector control 

RCP2 to RCP5 

Incremental Encoder, Battery-less Absolute Encoder    Resolution 800pulse/rev 

Corresponding 

Encoder 

RCP6 

Battery-less Absolute Encoder    Resolution 8192pulse/rev 

Actuator Cable Length 

MAX. 20m 

Serial Communication Interface 

(SIO Port) 

RS485  : 1 CH (based on Modbus Protocol RTU/ASCII) 

Speed  : 9.6 to 230.4Kbps 

Control available with serial communication in the modes other than the pulse train

PIO Type 

Signal I/O dedicated for 24V DC (selected from NPN/PNP) … Input 16 points max., 

output 16 points max. 

Cable length    MAX. 10m 

External 

Interface 

Fieldbus Type 

DeviceNet, CC-Link, PROFIBUS-DP, CompoNet, MECHATROLINK-

/

EtherCAT, EtherNet/IP, PROFINET-IO, MECHATROLINK-

*, CC-Link IE*   

(* Some types cannot connect it.) 

Data Setting and Input 

PC Software, Touch Panel Teaching, Teaching Pendant, Data Setter 

Data Retention Memory 

Saves position data and parameters to non-volatile memory   

(There is no limitation to the number of times data may be written.) 

Operation Mode 

Positioner Mode/Pulse Train Control Mode (selected by parameter setting) 

Number of Positions in Positioner Mode  Standard 64 points, MAX. 512 points (PIO Type) 

(Note)  Number of positions differs depending on the selection in PIO pattern. 
Differential System (Line Driver System) : MAX. 200kpps 

Cable length    MAX. 10m 

Input Pulse Frequency 

Open Collector System : Not applicable. 

* If the host applies the open collector output, prepare AK-04 (option) separately to 

convert to the differential type. 

Command Pulse Multiplying Factor 

(Electrical Gear : A/B) 

1/50 

A/B 

<

 50/1 

Setting Range of A and B (set to parameter) : 1 to 4096 

Pulse 

Train 

Interface

Feedback Pulse Output 

None 

LED Display   

(mounted on Front Panel) 

SV (GN)/ALM (RD)  :  Servo ON/Alarm generated 

STS0 to 3 

:  Status display 

RDY (GN)/ALM (RD)  :  Absolute function in normal / absolute function error (for the 

simple absolute type) 

1, 0 (GN) (RD) 

:  Absolute function status display (for the simple absolute type)

Electromagnetic Brake Compulsory Release 

Switch (mounted on Front Panel) 

Switching NOM (standard)/BK RLS (compulsory release) 

Insulation Resistance 

500V DC    10M

Ω

 or more 

Protection Function against Electric Shock 

Class I basic insulation 

Incremental Type 

Screw fixed type : 250g or less 

DIN rail fixed type : 285g or less 

Screw fixed type : 270g or less 

DIN rail fixed type : 305g or less 

Weight 

(Note3)

 

Simple Absolute Type 

(including 190g for battery) 

Screw fixed type : 450g or less 

DIN rail fixed type : 485g or less 

 

 

Cooling Method 

Natural air-cooling 

Forced air-cooling

 

External dimensions 

Screw fixed type : 35W×178.5H×69.6D

DIN rail fixed type : 35W×185H×78.1D

Screw fixed type : 35W×190H×69.6D 

DIN rail fixed type : 35W×196.5H×78.1D 

Surrounding Air Temperature  0 to 40

°

Surrounding Humidity 

85%RH or less (non-condensing) 

Surrounding Environment 

[Refer to Installation Environment] 

Surrounding Storage 

Temperature 

-20 to 70

°

C (Excluding battery) 

Usage Altitude 

1000m or less 

Protection Class 

IP20 

Environment

Vibration Durability 

Frequency 10 to 57Hz / Swing width : 0.075mm 

Frequency 57 to 150Hz / Acceleration 9.8m/s

2

 

XYZ directions    Sweep time : 10 minutes    Number of sweep : 10 times 

 

Note1    Add an additional 0.3A inrush for Fieldbus Types. 
Note2  In-rush current will flow for approximately 5msec after the power is turned on (at 40

°

C). 

Note that the value of in-rush current differs depending on the impedance of the power supply line. 

Note3    Add an additional 30g for CA/CB/CGB Fieldbus Type. Add an additional 10g for CFA/CFB/CGFB Fieldbus Type. 

 

ACON, DCON List of Specifications 

Description 

Item 

ACON-CA/CB/CGB 

DCON-CA/CB/CGB 

Number of controlled axes 

1-axis 

Power-supply Voltage 

24V DC 

±

10% 

Series  Motor Type 

Rated 

Max. Power 

Consumption MAX.

(Note5)

Rated 

MAX. 

2W 

0.8A 

 

4.6A 

5W 

1.0A 

 

6.4A 

10W (RCL) 

1.3A 

 

6.4A 

10W (RCA/ RCA2)  1.3A 

2.5A 

4.4A 

20W 

1.3A 

2.5A 

4.4A 

20W (Model: 20S) 

1.7A 

3.4A 

5.1A 

RCA, 

RCA2, 

RCL 

30W 

1.3A 

2.2A 

4.0A 

 

 

Load 

Capacity

(It does 

not 

including 

control 

side 

current 

consump

tion) 

(Note1)

RCD 

3W 

 

 

 

0.7A 

1.5A 

Power Supply for Electromagnetic 

Brake (for actuator equipped with brake)  24V DC 

±

10%    0.15A (MAX.) 

Heat Generation 

8.4W 

4W 

Rush Current 

(Note2)

 

10A 

Transient Power Cutoff Durability 

MAX. 500

μ

<Identification for IAI use only> 

* There is no identification in some cases.

 
<Type of Installation>

 

(Not Specified)  :  Screw Attachment Type
DN 

:  DIN Rail Mounting Type

 
<Applicable to Simplified Absolute Unit> 

(Not Specified): Incremental 

/ Battery-less Absolute 

AB 

: Simple Absolute Type 

 

  (With the Absolute Battery) 

ABU  : Simple Absolute Type 
 

  (With the Absolute Battery Unit 

 

  (SEP-ABU)) 

ABUN : Simple Absolute Type 
 

  (With no Absolute Battery) 

 
<Power-supply Voltage> 

0 : 24V DC 

 

<I/O Cable Length> 

0 : Equipped with no cable 
2 : 2m (Standard) 
3 : 3m 
5 : 5m 

Warning :  Operation of this equipment requires detailed installation and operation instructions which are 

provided on the DVD Manual included in the box this device was packaged in. It should be retained 

with this device at all times. 

 

A hardcopy of the Manual can be requested by contacting your nearest IAI Sales Office listed at   

the back cover of the Instruction Manual or on the First Step Guide. 

Serial number 

Model 

Model
SER NO.
Input
Output
Actuator

*

*

CAUTION: Connect the wiring correctly and
 

properly, use IAI specified cables

 

or min 60°C Cu wire.

IP20

*********

*********

DC24V   A
0-24Vac,3ph,0-333Hz,       A

*****

Applicable to Fieldbus

<Identification for IAI use only> 

* There is no identification in some cases.

 
<Type of Installation>

 

(Not Specified)  :  Screw Attachment Type
DN 

:  DIN Rail Mounting Type

 
<Applicable to Simplified Absolute Unit> 

AB 

: Simple Absolute Type 

 

  (With the Absolute Battery) 

ABU  : Simple Absolute Type 
 

  (With the Absolute Battery Unit 

 

  (SEP-ABU)) 

ABUN : Simple Absolute Type 
 

  (With no Absolute Battery) 

 
<Power-supply Voltage> 

0 : 24V DC 

 

<I/O Cable Length> 

0 : Equipped with no cable 
2 : 2m (Standard) 
3 : 3m 
5 : 5m 

<Identification for IAI use only> 

* There is no identification in some cases.

 
<Type of Installation>

 

(Not Specified)  :  Screw Attachment Type
DN 

:  DIN Rail Mounting Type

 
<Power-supply Voltage> 

0 : 24V DC 

 

<I/O Cable Length> 

0 : Equipped with no cable 
2 : 2m (Standard) 
3 : 3m 
5 : 5m 

<Series> 

 

<Type> 

CA/CB 

:

 

Standard Type 

CFA/CFB  :

 

High-Thrust Actuator 

 

 

Connection Type 

CGB 

 

:

 

Sagety Categories Complied Type 

CGFB 

 

:

 

High-Thrust Actuator   

 

 

Connection Sagety Categories 
Complied Type 

 

<Detail of Connected Axis> 

[Motor Type] 
20P : 20□ pulse motor, 20SP : 20□ pulse motor 
28P : 28□ pulse motor, 28SP : 28□ pulse motor 
35P : 35□ pulse motor, 

 

42P  : 42□ pulse motor 

42SP : 42□ pulse motor, 56P : 56□ pulse motor 
56SP : 56□ pulse motor, 60P

 

: 60□ pulse motor 

86P : 86□ pulse motor 
[Encoder Type] 
WAI : Incremental / Battery-less Absolute Shared 
SA  : Simple Absolute 
 

<I/O Type> 

NP  : NPN Type (Sync. Type) (Standard), 
PN  : PNP Type (Source Type), 
PLN : Pulse Train Control NPN Type (Sync. Type), 
PLP  : Pulse Train Control PNP Type (Source Type), 
DV  : DeviceNet Connection Type,            CC  : CC-Link Connection Type 
PR  : PROFIBUS-DP Connection Type, 

 

CN  : CompoNet Connection Type 

PRT : PROFINET-IO Connection Type,   

 

EC  : EtherCAT Connection Type 

EP  : EtherNet/IP Connection Type,       

 

ML  : MECHATROLINK-

/

  Connection Type 

ML3 : MECHATROLINK-

  Connection Type (Except for PCON-CA/CFA) 

CIE  : CC-Link IE Type (PCON-CB/CFB/CGB/CGFB only) 

<Series> 

 

<Type> 

CA/CB : Standard Type 
CGB   

 

:

 

Safety Categories Complied Type 

 
<Detail of Connected Axis> 

[Motor Type] 

: 2W  AC servo motor 

: 5W  AC servo motor 

10  : 10W  AC servo motor 
20S : 20W  AC servo motor 
20  : 20W  AC servo motor 
30  : 30W  AC servo motor 
[Encoder Type] 
WAI : Incremental / Battery-less Absolute 

 

 

shared (CB only) 

: Incremental 

A  : Serial Absolute 

[Option] 
HA : High Acceleration/Deceleration Type 
LA : Low Power Consumption Type 
No description : Standard Type 
 

<I/O Type> 

NP  : NPN Type (Sync. Type) (Standard), PN : PNP Type (Source Type), 
PLN : Pulse Train Control NPN Type (Sync. Type), 
PLP  : Pulse Train Control PNP Type (Source Type), 
DV  : DeviceNet Connection Type,            CC  : CC-Link Connection Type 
PR  : PROFIBUS-DP Connection Type, 

 

CN  : CompoNet Connection Type 

PRT : PROFINET-IO Connection Type,   

 

EC  : EtherCAT Connection Type 

EP  : EtherNet/IP Connection Type, 

ML  : MECHATROLINK-

/

  Connection Type 

ML3 : MECHATROLINK-

  Connection Type (Except for ACON-CA) 

CIE  : CC-Link IE Type (ACON-CB/CGB only) 

<Series> 

 

<Type> 

CA/CB : Standard Type 

 
<Detail of Connected Axis> 

[Motor Type] 

: 2.5W  DC Brushless motor 

[Encoder Type] 

: Incremental 

 

<I/O Type> 

NP  : NPN Type (Sync. Type) (Standard), PN : PNP Type (Source Type), 
PLN : Pulse Train Control NPN Type (Sync. Type), 
PLP  : Pulse Train Control PNP Type (Source Type), 
DV  : DeviceNet Connection Type,            CC  : CC-Link Connection Type 
PR  : PROFIBUS-DP Connection Type, 

 

CN  : CompoNet Connection Type 

PRT : PROFINET-IO Connection Type,   

 

EC  : EtherCAT Connection Type 

EP  : EtherNet/IP Connection Type, 

ML  : MECHATROLINK-

/

  Connection Type 

ML3 : MECHATROLINK-

  Connection Type (Except for DCON-CA) 

CIE  : CC-Link IE Type (DCON-CB only) 

Summary of Contents for ACON-CA

Page 1: ...ection Function against Electric Shock Class I basic insulation Incremental Type Screw fixed type 250g or less DIN rail fixed type 285g or less Screw fixed type 270g or less DIN rail fixed type 305g or less Weight Note3 Simple Absolute Type including 190g for battery Screw fixed type 450g or less DIN rail fixed type 485g or less Cooling Method Natural air cooling Forced air cooling External dimens...

Page 2: ... Serial Absolute Type Option Side View Battery less Absolute Incremental Type 104 from DIN rail center 35 4 Width of 35mm DIN rail for FG cable attachment for FG cable attachment for FG cable attachment External Dimensions PCON CFA CFB CGFB Screw fixed type DIN rail fixed Installation Environment This product is capable for use in the environment of pollution degree 2 1 or equivalent 1 Pollution D...

Page 3: ...r of occupied stations 4 Stations Number of occupied stations 1 Station RX n0 to nF Port No 0 to 15 2 Occupied Domain Port No 0 to 15 2 RX n 1 0to n 1 F System Domains System Domains System Domains RX n 2 0to n 2 F Occupied Domain RX n 3 0to n 3 F System Domains RX n 4 0to n 4 F RX n 5 0to n 5 F RX n 6 0to n 6 F Occupied Domain RX n 7 0to n 7 F System Domains RWr n 0 RWr n 1 Current Position Curre...

Page 4: ...he operation is performed MS OR Illuminating A communication hardware error was detected in the operation preparation mode Pin No Description Contents 3 B Line RxD TxD Communication Line on the Plus Terminal Side 5 GND Signal Cable Grounding Insulated 6 5V 5V Output Insulated 8 A Line RxD TxD Signal Line on the Minus Terminal Side Housing Shield Cable Shield for Case and Connection Wiring Bus Term...

Page 5: ...using specific parameters Set the parameter No 85 NADR Fieldbus Node Address using the personal computer application software for RC Settable Range 61 to 7F hex It is set to 61 when the machine is delivered from the factory Communication Speed Setting Set the parameter No 86 FBRS Fieldbus Communication Speed using the personal computer application software for RC Manual No ME0303 7A Check of Packe...

Reviews: