i4Technology EcoLife Pro1 Instruction Manual Download Page 8

the choice by pushing  the 

«ОК»

 or «˃» button; 

- choose the language 

«РУССКИЙ»

 or 

«ENGLISH» 

in the

 

opened submenu and confirm 

the  language  by  pushing  the 

«ОК» 

button.  You’ll  see  the  check  mark  opposite  the  chosen 

language; 

- by pushing the buttons  

«<»

 or 

 come back to the Main menu for further  settings. 

 

2.3.1.2. Measurement mode settings   
 

When  you  are  in  the  Main  menu  (Fig.  7)  chose  the  line 

«ИЗМЕРЕНИЕ 

(MEASUREMENT)» 

by pushing the buttons

 «˄» 

and

 «˅» 

and confirm your choice by pushing 

the buttons 

«ОК»

 or 

«˃»

. You’ll see the Measurement settings menu

 

on the display (Fig. 8). 

 

 

 

Figure 8 – Measurement mode settings

 

 
2.3.1.3 Selecting the units of measurement 
 

-  in  the  opened  submenu  (Fig.  8)  chose  the  line 

«ЕД.ИЗМЕРЕНИЯ  (UNITS)» 

and 

confirm your choice by pushing the buttons

 «ОК»

 or 

«˃»

-  choose  the  units  of  measurement 

«РЕНТГЕН  (ROENTGEN)»

  or 

«ЗИВЕРТ 

(SIEVERT)»,

  confirm  your  choice  by  pushing  the  button

  «ОК»

.  You’ll  see  the  check  mark 

opposite the chosen unit; 

-  by  pushing  the  button 

«<»

  come  back  to  the  Measurement  settings  menu  (Fig.  8)  for

 

further  settings. 

 

2.3.1.4 Setting the threshold of the ambient dose rate (above which the device sounds 

because the radiation level is high) 

 

- when you are in the Measurement settings menu

 

(Fig. 8), by pushing the buttons 

«˄»

 and 

«˅»

  choose  the  line 

«ПОРОГ  МКРН  (МКЗВ)  (THRESHOLD  MKR(MKS)»

  and  confirm 

your choice by pushing the buttons 

«ОК»

 or 

«˃»

-  choose  one

 

of  the

 

available

 

threshold  values  by  pushing  the  buttons 

«˄»

  and 

«˅»

Confirm your choice by pushing the 

«ОК» 

button; you’ll see the check mark opposite the chosen 

value; 

-  by  pushing  the  button    «<»  come  back  to  the  Measurement  settings  menu

 

(Fig.  8) 

 

for 

further  settings. 

 

2.3.1.5 Reset the dose summarized during the previous measurements 
 

- when you are in the Measurement settings menu

 

(fig.  8), by pushing the buttons  

«˄»

 and 

«˅»

  choose  the  line

  «СБРОС  НАКОПЛ  (RESET  TOTAL)»

  and  confirm  your  choice  by 

pushing the buttons 

«ОК»

 or 

«˃»

- choose 

«ОК», 

if you want to reset the readings of the dose summarized for all the time of

 

working  to  start  recording  a  new  value  of  the  dose  accumulated,  or  choose 

«ОТМЕНА 

(CANCEL)»

 if you want to reject the reset. 

Summary of Contents for EcoLife Pro1

Page 1: ...Package and transportation 6 Proof of acceptance 7 Manufacturer s warranty 8 Certification information Warranty Card Appendix General information of the radiation nature and the material radiation in...

Page 2: ...ifferent readings This situation is similar to the rain in everyday life When there is a bit of rain it s difficult to detect how many drops drip per second by hand there may be 2 drops more or no one...

Page 3: ...accumulated dose selecting the unit measures roentgen Sievert setting and changing the alarm sound of the ambient dose rate threshold audiovisual warning of the ambient dose rate threshold excess sett...

Page 4: ...re than 105 58 18 5 Mass with batteries grams not more than 110 1 3 Contents of the box 1 3 1 The table below gives the information about parts of the product and the delivery set Table 2 Name number...

Page 5: ...nging from 10 to 80 seconds depending on the radiation rate The displayed values are automatically changing and being averaged by the microprocessor This averaging process is displayed by the measurem...

Page 6: ...iation dose considered safe During the life the accumulated dose value must be below 100 700 millisieverts summarized according to the local radiation background 1 4 4 Control buttons are used to swit...

Page 7: ...edure To prepare the product for working you should loosen the screw and remove the battery compartment cover no 3 Fig 2 install the batteries respecting polarities Fig 4 place back the battery compar...

Page 8: ...button come back to the Measurement settings menu Fig 8 for further settings 2 3 1 4 Setting the threshold of the ambient dose rate above which the device sounds because the radiation level is high wh...

Page 9: ...opposite the chosen brightness and the screen brightness will be changed according to your choice by pushing the button come back to the Screen settings menu fig 9 for further settings 2 3 1 8 Setting...

Page 10: ...hing the buttons choose the line BUTTONS SOUND and confirm your choice by pushing the button or by pushing the buttons and choose the value ON or OFF to switch the buttons sound on and off and confirm...

Page 11: ...rgy of the batteries when user forgets to switch off the device For settings you should when you are in the Main menu 7 by pushing the buttons choose the line SETTTINGS and confirm your choice by push...

Page 12: ...e the line SETTTINGS and confirm your choice by pushing the button or in the opened submenu by pushing the buttons and choose the line ACCUMULATOR and confirm your choice by pushing the button or by p...

Page 13: ...dio signal passing frequency occur At the same time the ambient dose value is raising in the upper right corner of the screen and the columns at the radiation environment time based historical graphs...

Page 14: ...e the natural radiation background normal for the location it indicates that the object you investigate is polluted by radiation To define the ionization radiation source you should remove the working...

Page 15: ...pair should be carried out by the dealer 5 Package and transportation Every Product delivery set see Table 2 is packaged in individual corrugated fiberboard box The moving of contents of the box is no...

Page 16: ...or the authorized Distributor shall replace or repair the products broken down during the guaranteed use period at the expense of them 7 5 This warranty shall be void if guaranteed use period is over...

Page 17: ..._________________________________________________________________________ Sale Date _________________________________________________________________________ Vendor s stamp and signature _____________...

Page 18: ...es caused to biological tissues by ionizing radiation exposure depend on the dose of absorbed radiation energy To characterize it the term absorbed dose is used i e the energy absorbed by the unit of...

Page 19: ...The equivalent dose rate H is defined by the formula H dH dT where dT is a period of time In the SI system the equivalent dose rate H is measured by Sievert per second Sv s 1 Sv s 100 Rem s 1 Sv s R s...

Reviews: