5.  Package and transportation

 

 

Every product delivery set (see Table 2) is packaged in an individual container. Do not move the goods 

inside the package. Packaged products are put into the cargo corrugated containers according to the GOST 

22637. 

Packaged products can be transported by train or by trucks in covered trucks or containers or by air transport 

in pressurized modules. 

While transporting the packaged products should be protected from the direct impact of atmospheric 

condensation and insolation.   

Transportation terms and conditions: 

- Environment temperature: from -50 to 50°

С

- Humidity at 25°

С

: below 95%; 

- Atmospheric pressure: from 84 to 107 kPa (from 630 to 800 millimeters of mercury); 

- Shock acceleration peak values: below 147 m/s2 (15 g), with shock acceleration duration 10…15 ms. 

The requirements specified on the package warning labels must be strictly observed during loading and 

transportation. 

       6. Proof of acceptance 

EcoLife PRO-2 nitrate meter TC 4215-008-6406207-2015 

manufacturing number ____________________ 
manufacture date ____________________ 

is manufactured and accepted according to the valid technological documents and considered exploitable. 

QC stamp ___________________ 

 

      

7. Manufacturer’s warranty 

7.1. Manufacturer warrants that the Product satisfies the technical requirements of the TC 4215-008-

6406207-2015 while observing the operation, storage and transportation regulations indicated on 

exploitative documents. 

7.2. The service life of the Product is not less than 5 years (with the average operation rate 4 hours per day). 

7.3. The warranty period is 12 months from the date of sale. If the sale date and the vendor’s stamp in the 

warranty card are absent the guaranteed use period will be calculated from the date of manufacture.  

7.4. The supplier (manufacturer or a complete service provider) shall replace or repair the products broken 

down during the warranty period by and at the expense of the supplier.  

Summary of Contents for EcoLife PRO-2

Page 1: ......

Page 2: ...and operation area 1 2 Technical features 1 3 Device components 1 4 Internal design and operating 2 Correct use 2 1 Usage limitations 2 2 Operating 3 Technical service 4 Failure table 5 Package and t...

Page 3: ...food both in stomach and intestinal tract Attention Please note that the measuring results of the present device cannot replace chemical analysis performed in a professional laboratory The product is...

Page 4: ...substance per million particles of water are performed by the device 1 1 2 The software of the equipment provides original algorithm of measuring the quantitative nitrate content in foods and the salt...

Page 5: ...ax 120 Table1 1 3 Device components 1 3 1 Table 2 below gives the information about the device components and contents of delivery Name Number Note 1 EcoLife PRO 2 nitrate meter TC 4215 008 6406207 20...

Page 6: ...des measuring and indicating of quantitative nitrate content in foods and salt content in water The product also provides indicating of additional information that includes data day month year current...

Page 7: ...pe instead of batteries In this case charge the accumulators by yourself using the external power supply 2 Correct use 2 1 Usage limitations 2 1 1 Keep the battery compartment and the power contacts c...

Page 8: ...od groups and confirming the choice of a food group are performed by the button box Picture 5 Food group selection menu Pressing the buttons or moves the user into one of the four food groups menus ve...

Page 9: ...black background see Picture 6 you need to immerse the measuring probe into its flesh or immerse it in water while measuring TDS by two thirds of the measuring probe s length and press the button or Y...

Page 10: ...ring probe s connecting thread into the flesh of vegetables and fruits or in water It can lead to a short circuit and put the device out of operation Optimal depth of measuring probe s immersion is 2...

Page 11: ...t pressed for more than 2 seconds At that the total history list can be called up from food group menu or food group s items list The total history list will be displayed on the screen see Picture 11...

Page 12: ...open the Settings menu press the button To navigate through the Setting menu use and use the button to confirm the selection of a Setting menu item see Picture 13 To exit the Setting menu press the bu...

Page 13: ...so To cancel time settings press the button exit to the Settings menu or exit to the Food group menu Picture 15 Date setting 2 2 4 3 Time setting To set the time you need to enter the Settings choose...

Page 14: ...es If you see the runs of the battery acid renew them 3 4 After operating unthread the measuring probe from enclosure and rub it dry by a cotton napkin 4 Failure table Table 3 contains the troubleshoo...

Page 15: ...during loading and transportation 6 Proof of acceptance EcoLife PRO 2 nitrate meter TC 4215 008 6406207 2015 manufacturing number ____________________ manufacture date ____________________ is manufact...

Page 16: ...age and transportation regulations are violated the product put into service failed due to mechanical defects the seal is broken 7 6 When the warranty period ends the maintenance of the Product will b...

Page 17: ...____________________________________________________________________ Sale Date _________________________________________________________________________ Vendor s stamp and signature __________________...

Reviews: