High Speed Network Dome Camera Ax63Z
QUICK START GUIDE
i3 INTERNATIONAL INC.
1.866.840.0004
www.i3international.com
U.S.A 1967 Wehrle Drive, Suite 1,
PMB# 034 Buffalo NY, 14221
Canada 780 Birchmount Road, Unit 16,
Scarborough, ON, M1K 5H4
WALL MOUNT
1. Remove the secure plate and drill 4 holes on wall matching mount holes on plate.
2. Hammer 4 screw mounts into holes and secure plate.
3. Fasten connector ring to wall hang support in clockwise direction.
4. Thread cabling of main unit through aluminum tube and push cables out from bottom.
5. Pull out cables and connect main unit to connector ring in clockwise direction
6. Use hex key to secure set screw to connector ring and fasten the safety cable to
tube.
CONNECT CAMERA TO i3 SRX-PRO SERVER
i3 SRX-Pro Server
Crossover direct connection
LAN
i3 SRX-Pro Server
Via Gigabit Switch
Connection Type 1:
Connection Type 2:
PARAPET WALL MOUNT
1. Remove the secure plate and drill 8 holes on wall matching
mount holes on plate.
2. Hammer 8 screw mounts into holes and secure plate.
3. Fasten connector ring to L tube in clockwise direction.
4. Thread cabling of main unit through aluminum tube and
push cables out from bottom.
5. Pull out cables and connect main unit to connector ring in
clockwise direction
6. Use hex key to secure set screw to connector ring and
fasten the safety cable to tube.
7. Insert entire tube including main
unit into hole fitting on secure
plate
8. Rotate tube 180 degrees
clockwise with secure plate and
fasten screws.
1. Remove ceiling support frame and attach connector ring to
the aluminum tube in clockwise direction.
2. Mark the ceiling matching 4 mount holes on ceiling support
frame.
3. Drill 4 holes, hammer 4 wall screws into holes.
4. Secure entire ceiling support frame to screw mounts.
5. Fasten connector ring to wall hang support.
6. Thread cabling of main unit through short aluminum tube and
push cables out from bottom.
7. Pull out cables and connect main unit to connec-
tor ring in clockwise direction. Use hex key to secure
set screw to connector ring and fasten safety cable
to tube.
1.
Close SRX-Pro Server software by pressing
Alt+Shift+Ctrl+F4
.
2.
Change the IP address on the onboard NIC (LAN) (or on NIC1 if your SRX-Pro
Server has two onboard NIC cards) of your SRX-Pro Server to 192.0.0.XXX to
match the default IP range of your Annexxus IP camera.
3.
Connect your camera to i3 SRX-Pro Server (see diagram above).
4.
Turn on your Annexxus camera.
5.
Launch the CD that came with your Annexxus camera and double-click
“
AnnexxusFinder.exe
” file to install Annexxus Finder application. Annexxus
Finder application discovers all Annexxus cameras connected to your network.
6.
Select desired camera in the Annexxus Finder software by double-clicking it in
the list and click
Edit
.
7.
Enter the new IP address and Subnet Mask of the camera in the Change IP
Address area. The new camera IP address must match the
original range of your
SRX-Pro LAN or NIC1 card.
E.g. If your original SRX-Pro Server’s IP address was 192.138.10.122, change
your Annexxus camera’s IP address to 192.138.10.XXX.
8.
Follow the Annexxus Finder installation instructions until the application has been
successfully installed on your SRX-Pro Server.
9.
Double-click Annexxus Finder icon on the Desktop to launch the application.
The application window will appear displaying a list of active network cameras.
Remember: Annexxus Cameras cannot share an IP address, each camera
requires its own unique IP address.
10.
Enter the default camera password in the Input Password field and click
Save
.
11.
Wait a few moments for a successful confirmation window. Click
OK
to close it.
12.
Repeat Steps 1-12 for all detected Annexxus cameras in the Annexxus Finder.
13.
Make sure you can connect to the camera through Internet Explorer:
a.
Launch Internet Explorer and enter the IP Address you have just assigned to
your Annexxus camera. The password window should be displayed.
b.
Enter the default camera User Name
and the default Password.
c.
Annexxus camera interface will be displayed in the Internet Explorer
window. You should be able to see the camera image on the screen.
If you do not see the camera image on the screen, call i3 International tech
support for troubleshooting tips: 1.877.877.7241
14.
Make sure that the latest version of GiPi updater is installed on your SRX-Pro
Server. You can download the updates from ftp://files.123ip.com/drivers/gipi.
Please contact i3 Technical Support team for access information.
15.
Once the latest GiPi updater has been installed, restart i3 SRX-Pro Server
software.
16.
Log In and go to the
Setup
->
IP Camera
tab.
17.
Click the
Search
button to display connected Annexxus cameras.
18.
Select the detected camera in the list and click
Select
.
19.
In the
Select IP Camera window, enter the default camera User Name and the
default Password, then click
Add
.
20.
The selected camera will be added to the IP Camera list.
Don’t forget to assign the IP camera to the SRX-Pro video channel in the
corresponding column.
21.
Your Annexxus camera is now connected to SRX-Pro Server and is ready to
record. You may change resolution and frame rate for the Annexxus camera in
the IP Camera tab menu or you may choose to configure the camera’s advanced
settings.
Camera’s default IP:
192.0.0.16
.
FW ver. ANNEXXUS 63Z.0.1.4670 | Login:
admin
/ PW:
1234
FW ver. ANNEXXUS 63Z.0.1.5025, or higher | Login:
i3admin
/ PW:
i3admin
PENDANT PIPE MOUNT