Am42R Analog Dome Camera

UP

Focus Lever + 

locking screw 

(Far/Near)

F N

Zoom Lever + 

locking screw 

(Tele/Wide)

T W

INSTALLING THE CAMERA

Prepare the mounting surface.
•  Depending on the type of 

installation, additional mounting 
accessories may need to be 
purchased.

•  It is the installer’s responsibility 

to ensure that the mounting 
surface is suitable for the chosen 
installation method.

•  Based on installation location and 

surface type, supplied screws and anchors 
may not be adequate. Mounting hardware 
is site-specific and may need to be supplied by the 
installer.

SURFACE MOUNTING

1. 

Use the supplied security Torx key to loosen three 
screws securing the dome bubble housing to camera 
module. Gently pull the dome bubble away from the 
main camera module.

2. 

Temporarily remove the camera liner/shroud for 

3-axis Range Limitations:

Pan:

0 - 355°

Tilt:

 0 - 75°

Rotation: 

0 - 355°

10. 

Connect camera to 12DC or 24AC power 
and attach the service monitor to the 2-pin 
connector on the camera.

11. 

Adjust the lens angle by panning and tilting the 
camera lens assembly and rotating the camera 
lens base. Do not over-rotate the camera lens 
beyond the stop point to avoid damage to the 
camera.

12. 

Adjust the camera’s zoom and focus using Zoom 
/ Focus levers on the camera module. Loosen 

CVBS / TVI 

dipswitch

2-pin Service 

Monitor 

connector

image brightness, colour or contrast, day/night mode, etc.). 

See CAMERA MENU 

section for more information on camera’s on-screen menu.

14. 

Set the video format dip switch to the desired setting: 

CVBS

 (standard composite video, 720x480) or 

TVI

 (high-definition video, 1MP). Depending on the dip switch 

selection, the matching BNC video connector will be enabled on 

the camera. 

Joystick

IMPORTANT: 

In order to be able to use high-definition video, your 

Am42R camera 

must be connected to i3’s HR16 video encoder.

 

15. 

Once the desired view is achieved, unplug the service monitor and replace 
camera’s inner liner (shroud) until it snaps back into place.

16. 

Replace the camera dome bubble and re-tighten 3 silver screws securing the 
dome bubble to the camera base.

FLUSH MOUNTING

Am42R camera can be flush mounted with the use of i3’s flush mounting kit 

(Part # AM42FM). Sold separately. When flush-mounting the camera, do not use the 

supplied camera back box. 

Follow the mounting instructions supplied with the kit.

WALL MOUNTING w/ GOOSENECK BRACKET

the locking screws, adjust the lever and 
re-tighten the locking screw when desired 
view is achieved.

13. 

Use the joystick on the camera board to 

adjust any additional camera settings (e.g. 

If connecting directly to the HVR’s / DVR’s BNC panel, set the dip switch to CVBS to 

use 720x480 composite video cable.

Am42R

Back Box

DB60 

Gooseneck

Bracket

Use silicone

to maintain

IP66 rating

3/4” Rigid

Pipe

3/4” Electrical 

EMT Conduit 

Fitting

Use silicone

to maintain

IP66 rating

Am42R

Back Box

Am42R camera can be wall-mounted with the use 
of i3’s gooseneck wall bracket (Part # DB60). Sold 
separately. Together with the optional DB60CPM 
bracket, DB60 gooseneck bracket has the 
capability of being corner- or pole-mounted.
Follow the mounting instructions supplied 
with the DB60 bracket.
Attach the top conduit hole of the camera’s 
back box to the threaded end of the DB60 
bracket and rotate clockwise to attach the 
two together. Use silicone sealer to maintain IP66 
rating when installing outdoors.
Complete installation as for Surface Mounting from Step #8 onwards.

PENDANT POLE MOUNTING

Use a 3/4” Electrical EMT Conduit Fitting with a rigid 
3/4” pipe for this type of installation.
Attach the top conduit hole of the camera’s back 
box to the threaded end of the 3/4” Electrical EMT 
Conduit Fitting and rotate clockwise to attach the two 
together. 

Use silicone sealer to maintain IP66 rating 
when installing outdoors.
Complete installation as for Surface Mounting 
from Step #8 onwards.

easier lens adjustment.

3. 

Depending on the type of installation and mounting 
surface, complete drilling 2-4 holes in the back box 
in preparation for the mounting.

4. 

Attach the supplied mounting template to the 
mounting surface. 

5. 

Drill holes, as marked on the template and insert 
supplied anchors into the holes. The number and 
positioning of holes must match the ones pre-
drilled on the back box in Step 4.

6. 

Drill the conduit hole for the camera 
cable, as marked on the template, 
if using the top conduit hole to 
route cables. Skip is using the 
side conduit hole. 

7. 

Use three tapping screws provided 
to secure the camera’s back box to 
the prepared mounting surface.

8. 

Feed the camera cables through the 
selected conduit hole. Use silicone sealer 
around the chosen conduit hole to maintain IP66 rating when installing outdoors.

9. 

Use the supplied security Torx key to attach the camera module to the back box. Use 
three long machine-type screws pre-inserted into the camera module.

Summary of Contents for AM42R

Page 1: ... the Shroud Liner for easy access 9 2 pin Service spot monitor output 10 Power connector 12DC 24AC 11 TVI High definition analog video connector 1MP 1280x720 720P To use high definition analog stream 1MP the camera must be connected to i3 s HR16 encoder Put the Dip switch 7 into the TVI position to enable TVI video stream 12 CVBS standard format analog video connector 4CIF 720x480 Can be connected...

Page 2: ...ied with the kit WALL MOUNTING w GOOSENECK BRACKET the locking screws adjust the lever and re tighten the locking screw when desired view is achieved 13 Use the joystick on the camera board to adjust any additional camera settings e g If connecting directly to the HVR s DVR s BNC panel set the dip switch to CVBS to use 720x480 composite video cable Am42R Back Box DB60 Gooseneck Bracket Use silicon...

Page 3: ... left to right V flip images vertically upside down HV flip both horizontally and vertically CAMERA MENU MAIN MENU FUNCTION Under FUNCTION sub menu set DETECTION MASKING and ZOOM IN functions DETECTION Set the motion sensitivity to WEAK LOW MIDDLE or HIGH Next configure the Detection AREA AREA Configure settings for up to 4 separate Detection Areas Set the status to OFF ON to disable enable Set th...

Page 4: ...in Control AGC Low Middle High Off White Balance Auto Manual Electric Shutter NTSC 1 30 s to 1 50 000 s PAL 1 25 s to 1 50 000 s Video Output Selectable Note Use one at a time Must set on board camera dipswitch HD Video Output works only with i3 s HR16 encoder CVBS Output 1 x 1Vp p Composite Output 75Ω BNC HD Video Output 1 x Analog HD output Day Night Mode Colour BW Smart IR Other Features Motion...