The motor must be connected according to the electrical codes through a fused switch in order to     
protect the motor against electrical or mechanical overload conditions. The overload of the motor starter         
must be set at a level equal to the full load motor current listed on the motor nameplate. 

If the compressor is supplied with a motor starter, it is preset at the factory according to customer specifications. 
It is advisable to check that these settings are in line with the voltage at your location. If the voltage 
is different, please contact I.VA.CO. for motor and starter information. 

    Correct direction of rotation is marked by an arrow on the motor fan housing and is counterclockwise 

when looking at the motor from the motor's fan side.

After electrical connections have been made, the rotation of the motor should be checked. If 

backward, reverse any two leads of the three at the power connection.   

1.5        Pressure Connections 

    Use a pipe size that is at least the size of the compressor outlet connection. Smaller and long pipe lines result 

in a reduced compressor capacity. 

    Compressors operating in parallel on a common main line should have a manual or automatic operated   

shut-off valve or positive action check valve, installed in the pressure line.   

    Remove the plastic protective cap from the exhaust port prior to connection of compressor to the system. 

    Should process gas contain dust or other foreign particles, a suitable in line (inlet) filter should be 

connected to the inlet port. Consult I.VA.CO. for recommendations. 

The following thread sizes are standard on the compressors (NPT thread is available upon request) 

Model

 

Inlet Size

 

Exhaust Size 

      ICP 100 IF       

    G 1-1/2”     

    G 1-1/2” 

@ Inlet Silencer 

@Exhaust Connection Housing 

1.6    Oil Filling on Gear Box 

    The pump is shipped without oil in gear box. After level installation and correct rotation has been 

established, fill the pump with recommended gear oil through the oil fill port. Oil level should be over 3/4 
position on the oil sight glass as shown on the label.   

We recommend ISO VG150 gear oil or equivalent oils. 

·

Shell OMALA HD 150 or Amsoil GEAR LUBE 150 or ANDEROL # 4150

The following table gives the approximate quantities of oil required for each model. 

Capacity (liter) 

Pump Model

ICP 100     

0.75 

Summary of Contents for ICP Series

Page 1: ...llation and Operating Manual ICP SERIES VACUUM PUMP MODEL 100 2 2017 REV1 I VA CO Italian Vacuum Compressors Via delle Brigole 33 23877 Paderno d Adda LC Italy Tel 39 039 9281084 info ivaco it www iva...

Page 2: ...Labels 3 0 OPERATION 3 1 Start up 3 2 Stopping the compressor 3 3 Ambient operating conditions 4 0 MAINTENANCE 4 1 Compressor Lube Oil level type quantity change 4 2 Inlet filter 4 3 Maintenance char...

Page 3: ...ling The ICP Series compressors are identical in internal construction to ICV vacuum pump but are outfitted with different inlet and outlet accessories to allow for operation as a compressor 1 2 Unpac...

Page 4: ...g pipe lines result in a reduced compressor capacity Compressors operating in parallel on a common main line should have a manual or automatic operated shut off valve or positive action check valve in...

Page 5: ...Warning labels and its explanation Following warning labels are shown and attached on ICP series compressor 2 2 1 Read and Understand a manual Read and understand operator s manual before using this...

Page 6: ...epending on the mounting position of the filter be careful not to allow accumulated foreign material to fall in the pump suction inlet when removing the filter cartridge Horizontal filter installation...

Page 7: ...ation of the claws or chamber Remedy Clean the pumping chamber and the claws 5 4 2 Possible cause Coupling insert is worn Remedy replace coupling insert in motor compressor coupling 5 4 3 Possible Cau...

Page 8: ...DATA Model ICP 100 M3 Hour 60Hz 120 50Hz 100 Press conti Bar 60Hz 1 4 2 2 50Hz 0 8 1 4 2 2 Kw 60Hz 4 8 6 5 50Hz 3 4 5 5 RPM 60 50Hz RPM 3450 2850 Voltage Available V 208 230 460V 220 380V 230 400V 40...

Page 9: ...ASS y DRAWING ICP100 IF IEC ICP ICP ICP ICP ICP ICP ICP...

Page 10: ...ASS y DRAWING ICP 100 IF NEMA ICP ICP ICP ICP...

Page 11: ...5 Shield Cover Front with mat 1 213 Hexagon Bolt M12 x 25 4 25 Key for Gear 2 96 Accoustic Mat for Shield Cover front and Side 1 214 Hexagon Bolt NEMA only 4 26 Key for Coupling 1 97 Foot Rubber 30x20...

Page 12: ...I VA CO Italian Vacuum Compressors Via delle Brigole 33 23877 Paderno d Adda LC Italy 39 039 9281084 info ivaco it www ivaco it...

Reviews: