2.3    Location of the labels 

The labels of 2.2.1 Read and Understand a manual, 2.2.2 Burn Hazard, and 2.2.3 Loud noise Hazard 
shall be shown on the top of sound shield of the compressor. 

    The label of 2.2.4 Hazardous Voltage shall be shown on the cover of motor’s terminal box. 

2.0 SAFETY 

     

Please read the following safety notice carefully before operating the compressor.

 

2.1    General Notices 

-

Understand fully this installation and operating manual before operation.

-

The other person except authorized operator should not operate the compressor.

-

When the compressor is not properly working, it should be stopped immediately.

-

I.VA.CO. shall have no liability for any accident and failure arising from no compliance with

instructions in this manual.

2.2    Warning labels and its explanation 

Following warning labels are shown and attached on ICP series compressor. 

2.2.1 Read and Understand a manual: 

Read and understand operator

s manual before using this machine. 

2.2.2 Burn Hazard: 

Hot surface. Do not touch. 

2.2.3 Loud noise Hazard 

Loud noise hazard. Ear protection must be worn. 

2.2.4 Hazardous Voltage: 

 

Disconnect power before opening. Contact causes severe electrical shock

 

3.0    OPERATION 

3.1    Start-up 

    Check rotation of the motor as described in paragraph 1.4 Power Requirements. 
    Fill the compressor with oil as described in paragraph 1.5 - Oil Filling 

Run the compressor for a few minutes and then shut down. Check the   
oil level again and make sure the oil level is 1/2 position of oil sight glass at stop status. 

    Add oil though oil fill port on the top, if necessary. Compressor oil should only be added when the 

compressor is off   

3.2    Stopping the compressor 

    To stop the compressor, turn off the power. 

Summary of Contents for ICP 100

Page 1: ...allation and Operating Manual ICP SERIES VACUUM PUMP MODEL 100 2 2017 REV1 I VA CO Italian Vacuum Compressors Via delle Brigole 33 23877 Paderno d Adda LC Italy Tel 39 039 9281084 info ivaco it www ivaco it ...

Page 2: ...f Labels 3 0 OPERATION 3 1 Start up 3 2 Stopping the compressor 3 3 Ambient operating conditions 4 0 MAINTENANCE 4 1 Compressor Lube Oil level type quantity change 4 2 Inlet filter 4 3 Maintenance chart 5 0 PROBLEM SOLVING 6 0 TECHNICAL DATA 7 0 TYPICAL ICP SERIES ASSEMBLY DRAWING AND PARTS LIST INSTALLATION AND OPERATING MANUAL This manual is written to cover following contact less operating claw...

Page 3: ...pling The ICP Series compressors are identical in internal construction to ICV vacuum pump but are outfitted with different inlet and outlet accessories to allow for operation as a compressor 1 2 Unpacking Inspect the box and compressor carefully for any signs of damage incurred in transit 1 3 Location Install the compressor in a horizontal position on a level surface so that it can be evenly supp...

Page 4: ...ng pipe lines result in a reduced compressor capacity Compressors operating in parallel on a common main line should have a manual or automatic operated shut off valve or positive action check valve installed in the pressure line Remove the plastic protective cap from the exhaust port prior to connection of compressor to the system Should process gas contain dust or other foreign particles a suita...

Page 5: ...2 Warning labels and its explanation Following warning labels are shown and attached on ICP series compressor 2 2 1 Read and Understand a manual Read and understand operator s manual before using this machine 2 2 2 Burn Hazard Hot surface Do not touch 2 2 3 Loud noise Hazard Loud noise hazard Ear protection must be worn 2 2 4 Hazardous Voltage Disconnect power before opening Contact causes severe ...

Page 6: ...Depending on the mounting position of the filter be careful not to allow accumulated foreign material to fall in the pump suction inlet when removing the filter cartridge Horizontal filter installation is recommended to prevent this 3 3 Operating Conditions The ambient and suction air temperature must be between 5 and 40 C deg The standard versions may not be used in hazardous areas Also it is rec...

Page 7: ...nation of the claws or chamber Remedy Clean the pumping chamber and the claws 5 4 2 Possible cause Coupling insert is worn Remedy replace coupling insert in motor compressor coupling 5 4 3 Possible Cause Bearing noise Remedy replace bearings or call service agent for service or exchange program 5 4 4 Possible Cause Pressure regulator or safety valve noise Remedy replace Pressure regulator or Safet...

Page 8: ...L DATA Model ICP 100 M3 Hour 60Hz 120 50Hz 100 Press conti Bar 60Hz 1 4 2 2 50Hz 0 8 1 4 2 2 Kw 60Hz 4 8 6 5 50Hz 3 4 5 5 RPM 60 50Hz RPM 3450 2850 Voltage Available V 208 230 460V 220 380V 230 400V 400 690V dB A Ave 60Hz 83 50Hz 79 Oil Capacity Gear box Ltr 0 75 Inlet Outlet Connections BSP G 1 1 2 W x H mm 488 x 618 673 5 5kw L x W x H mm 60Hz 778 778 50Hz 717 742 778 Amb Operating Temp ºC 5ºC 4...

Page 9: ...ASS y DRAWING ICP100 IF IEC ICP ICP ICP ICP ICP ICP ICP ...

Page 10: ...ASS y DRAWING ICP 100 IF NEMA ICP ICP ICP ICP ...

Page 11: ...95 Shield Cover Front with mat 1 213 Hexagon Bolt M12 x 25 4 25 Key for Gear 2 96 Accoustic Mat for Shield Cover front and Side 1 214 Hexagon Bolt NEMA only 4 26 Key for Coupling 1 97 Foot Rubber 30x20xM8 50x30xM10 4 215 Set Screw M8 x 10 2 28 Power Lock 2 98 Cover Plastic Foot Mount ICP high 4 6 216 Set Screw M8 x 10 2 29 Washer Spring Lock 6mm 2 99 Grill for Fan 2 217 Round Head Bolt M5 x 12 5 3...

Page 12: ...I VA CO Italian Vacuum Compressors Via delle Brigole 33 23877 Paderno d Adda LC Italy 39 039 9281084 info ivaco it www ivaco it ...

Reviews: