For SD memory card errors, refer to “3.5.2 Configure the settings relating to the SD memory card [SD
memory card]”.
•
For angle of view errors, refer to “3.6.4.7 Register the initial installation angle of view”.
3.5.2 Configure the settings relating to the SD memory card [SD
memory card]
Click the [SD memory card] tab on the “Basic” page. (
®
“3.2.1 How to display the setup menu”, “3.2.2 How
to operate the setup menu”)
The settings relating to the SD memory card can be configured on this page.
Operating mode
[SD memory card]
Select “Use” or “Not use” to determine whether or not to use the SD memory card.
•
Default:
Use
[Ext. software mode]
Set this setting to “On” when the installed extension software uses the SD memory card in this product.
•
On:
The extension software can use the SD memory card in this product. In this case, recording on the
SD memory card using the functions of this product will be come unavailable.
•
Off:
The extension software cannot use the SD memory card in this product.
•
Default:
Off
Note
•
For further information about the extension software, refer to our technical information website <Control
No.: C0103>.
•
If you set the extension software mode from “On” to “Off”, formatting the SD memory card is
recommended.
•
If you are operating extension software that uses the SD memory card, the operation of recording to
the SD memory card is not guaranteed.
[Audio recording]
Select whether or not to save audio data when saving video data in MP4 format.
•
Off:
Does not save audio data to videos (MP4 format).
•
On:
Saves audio data to videos (MP4 format).
•
Default:
Off
Note
•
When “Audio recording” is used, it is necessary to set either of “Stream(1)”, “Stream(2)”, “Stream(3)”
or “Stream(4)” for “Recording format”.
[Remaining capacity notification]
When the E-mail notification function or the TCP alarm notification function is used to provide notification of
the remaining capacity of the SD memory card, select a level to be notified at from the following.
50%/ 20%/ 10%/ 5%/ 2%
•
Default:
50%
Note
•
Notification will be provided each time the remaining capacity goes below each of the specified values.