background image

11

 

When directly fixing on the installation surface

 

When fixing on the gangbox/ 
junction box

 

When fixing with the base bracket (WV-QJB504)

 

When fixing with the base bracket (WV-QJB501-W / WV-QJB501-B)

Ground wire 

(locally procured)

Technical information website

“Countermeasure for Lightning Surge”  

<Control No.: C0121>

M4: accessory (3 pcs.)

Recommended tightening torque: 

0.69 N·m {0.51 lbf·ft}

M4: accessory (3 pcs.)

Recommended tightening torque:

0.69 N·m {0.51 lbf·ft}

M3×6 mm {1/4 inches}

Recommended  

tightening torque:

0.69 N·m {0.51 lbf·ft}

M4: accessory (3 pcs.)

Recommended tightening torque: 

0.69 N·m {0.51 lbf·ft}

FRONT

Step5

Inside

Outside

M4: locally procured (3 pcs.) 

Minimum pull-out strength:  

196 N {44 lbf} (per 1 pc.)

Summary of Contents for WV-S65501-Z1

Page 1: ...companying documents mean that used electrical and electronic products and batteries must not be mixed with general household waste For proper treatment recovery and recycling of old products and used...

Page 2: ...a professional equipment For information about screws and other parts required for installation refer to the corresponding section of this document Direct current symbol Do not install or clean the ca...

Page 3: ...ong magnetic field is generated Locations near coasts directly subjected to sea breezes or locations subject to corrosive gases such as from hot springs volcanic regions etc Locations where the temper...

Page 4: ...Storage humidity 30 C to 60 C 22 F to 140 F 10 to 95 no condensation EXT I O terminals 5 ALARM IN1 Alarm input 1 Black white input Auto time adjustment input x1 ALARM IN2 Alarm input 2 ALARM OUT x1 A...

Page 5: ...t I O Cable connection terminal Plate cover accessory Attachment plate accessory Lower case Enclosure Decorative cover Camera main body Dome cover Parts and functions Front side Bottom side Installati...

Page 6: ...net cable When using neither the I O Cable nor microSD Go to following steps for the subse quent procedure Step 1 For side cable access When wiring with the base bracket WV QJB504 using a conduit Step...

Page 7: ...l I O or audio I O WV QCA501A For side cable access When wiring with the base bracket WV QJB504 using a conduit Decorative cover Inside Outside Do not use the base bracket WV QJB501 W WV QJB504 when u...

Page 8: ...ch M4 M4 locally procured 3 pcs M4 locally procured 4 pcs Fixing screw for attachment plate 4 pcs M4 accessory of WV QJB504 Operating Instructions WV QJB501 W WV QJB501 B Operating Instructions WV QJB...

Page 9: ...ic 10 m 32 8 feet Line 10 m 32 8 feet ALARM IN2 red GND black EXT I O 12 V DC 2P power cable accessory of WV QCA501A 4P alarm cable accessory of WV QCA501A 12 V DC red GND black ALARM IN3 gray ALARM I...

Page 10: ...How to assemble the waterproof RJ45 connector accessory Crimp the RJ45 plug Align with and then rotate until aligns with Waterproof RJ45 connector used for the existing camera Note When the waterproo...

Page 11: ...n website Countermeasure for Lightning Surge Control No C0121 M4 accessory 3 pcs Recommended tightening torque 0 69 N m 0 51 lbf ft M4 accessory 3 pcs Recommended tightening torque 0 69 N m 0 51 lbf f...

Page 12: ...Software Control No C0123 or i PRO Configuration Tool iCT Control No C0133 Bit accessory Enclosure fixing screw 4 places OPEN mark Projection part M4 4 places Recommended tightening torque 0 69 N m 0...