
• Microsoft, Windows, Windows Media, Microsoft Edge, and ActiveX are either registered trademarks or
trademarks of Microsoft Corporation in the United States and/or other countries.
• Intel and Intel Core are trademarks of Intel Corporation or its subsidiaries in the U.S. and/or other countries.
• Adobe, Acrobat, and Reader are either registered trademarks or trademarks of Adobe in the United States
and/or other countries.
• microSDXC Logo is a trademark of SD-3C, LLC.
• iPad and iPhone are trademarks of Apple Inc., registered in the U.S. and other countries.
• Android and Google Chrome are trademark of Google LLC.
• Firefox is a trademark of the Mozilla Foundation in the US and other countries.
• The word “QR Code” is a registered trademark of DENSO WAVE INCORPORATED in Japan and other countries.
• All other trademarks identified herein are the property of their respective owners.
Trademarks and registered trademarks
Troubleshooting
Before requesting service, refer to “Troubleshooting” of Basic Information and Operating Instructions. Then, confirm the trouble.
Precautions for installation
In order to prevent injury, the product must be securely mounted to an installation
surface according to Installation Guide.
Installation area for this product
Select an appropriate place for the installation area (such as a strong installation surface) in your particular environment.
• Make sure that the installation area is strong enough to hold this product, such as a concrete ceiling.
• Install the camera in the foundation area of the architecture or where sufficient strength is assured.
• Do not mount the product on a plaster board or a wooden section because they are too weak. If the product
is unavoidably mounted on such a section, the section shall be sufficiently reinforced.
Install the product in areas that do not receive direct sunlight.
When the product is installed outside in areas that receive direct sunlight, such as on external walls, use the
optional “WV-QSR500-W: Sun Shade”.
Specifications
*
*For further information, refer to the Basic Information.
About notations
The following notations are used when describing the functions limited for specified models.
The functions without the notations are supported by all models.
257V2L
The functions with this notation are available when using the model WV-S25700-V2L(4K model) series.
256V2L
The functions with this notation are available when using the model WV-S25600-V2L(6M model) series.
255V3L
The functions with this notation are available when using the model WV-S25500-V3L(5M model) series.
255F6L
The functions with this notation are available when using the model WV-S25500-V6L(Focal length 6.1 mm) series.
255F3L
The functions with this notation are available when using the model WV-S25500-V3L(Focal length 3.2 mm) series.
C
The functions with this notation are available when using the model with the clear dome cover.
G
The functions with this notation are available when using the model with the smoke dome cover.
W
The functions with this notation are available when using the model with the i-PRO white body.
B
The functions with this notation are available when using the model with the black body.
Copyright
Except for open source software licensed under GPL/LGPL and so on, distributing, copying, disassembling,
reverse compiling and reverse engineering of the software provided with this product are all expressly prohibited.
In addition, exporting any software provided with this product violating export laws is prohibited.
Power source *
1
:
DC 12 V
PoE (IEEE802.3af compliant)
Power consumption *
1
:
257V2L
256V2L
255V3L
DC 12 V:
1.0 A/ Approx. 12.0 W
PoE DC 48 V: 240 mA/ Approx. 11.5 W (Class 0 device)
255F6L
255F3L
DC 12 V:
880 mA/ Approx. 10.6 W
PoE DC 48 V: 220 mA/ Approx. 10.6 W (Class 0 device)
Operating environment
Ambient operating temperature:
Ambient operating humidity:
–40 °C to +60 °C *
2
{–40 °F to +140 °F}
(Power On range: –30 °C to +60 °C {–22 °F to +140 °F})
10 % to 100 % (no condensation)
Storage environment
Storage temperature:
Storage humidity:
–30 °C to +60 °C {–22 °F to +140 °F}
10 % to 95 % (no condensation)
Monitor output
(for adjustment):
VBS: 1.0 V [p-p]/75 Ω, composite, Pin jack
An NTSC or PAL signal can be outputted from camera
(either press the INITIAL SET button quickly (within 1 second) or use
software to select NTSC or PAL signal).
EXT I/O terminals:
ALARM IN 1
(Alarm input 1/ Black & white input/ Auto time adjustment input) (x1)
ALARM IN 2 (Alarm input 2/ ALARM OUT) (x1)
ALARM IN 3 (Alarm input 3/ AUX OUT) (x1)
Audio input:
For microphone input:
For line input:
ø3.5 mm stereo mini jack
Recommended applicable microphone: Plug-in power type
(Sensitivity of microphone: –51 dB to –38 dB (0 dB=1 V/Pa, 1 kHz))
Input impedance: Approx. 2 kΩ (unbalanced)
Supply voltage: 2.5 V ±0.5 V
Input level: Approx. –10 dBV
Audio output *
3
:
ø3.5 mm stereo mini jack (Audio output is monaural.)
Output impedance: Approx. 600 Ω (unbalanced)
Output level: –20 dBV
Waterproof *
4
:
IP66 (IEC 60529), Type 4X (UL50E)
NEMA 4X compliant
Shock resistance:
50 J (IEC 60068-2-75 compliant), IK10 (IEC 62262)
Wind resistance:
Up to 40 m/s {approx. 89 mph}
Dimensions:
ø154 mm × 105 mm (H) {ø6-1/16 inches × 4-1/8 inches (H)}
Dome radius 42 mm {1-21/32 inches}
(excluding attachment for the conduit portion)
Mass:
Approx. 1.1 k
g
{2.43 lbs}(excluding attachment for the conduit portion)
Finish:
Main body:
Aluminum die cast,
W
B
Outer fixing screws:
Stainless steel (Corrosion-resistant treatment)
Dome cover:
PC resin,
C
G
• WV-S25700-V2LN, WV-S25700-V2LN1, WV-S25600-V2LN,
WV-S25500-V3LN, WV-S25500-V3LN1
:with ClearSight coating
Others:
Tamper-resistant enclosure*
5
i-PRO Co., Ltd. assumes no responsibility for injuries or property damage resulting from failures arising
out of improper installation or operation inconsistent with this documentation.
Optional accessories
<Brackets>
<Dome covers, Cables>
Mount bracket:
WV-QSR501-W, WV-QSR501-B
,
WV-QSR501F-W, WV-QSR501M-W
WV-QSR501F1-W, WV-QSR501M1-W
Dome cover (Smoke type):
WV-CW7S
Dome cover
(Smoke type with ClearSight coating): WV-CW7SN
Base bracket:
WV-QJB501-W, WV-QJB501-B
Dome cover
(Clear type with ClearSight coating): WV-CW7CN
Wall mount bracket:
WV-QWL500-W, WV-QWL500-B RJ45 Ethernet cable:
WV-QCA500A
Ceiling Mount Bracket: WV-QEM500-W
I/O cable:
WV-QCA501A
The latest information
→
Technical information website “Accessory Selector” <Control No.: C0501>
Standard accessories
Installation Guide(English / Japanese) ...... 1 pc.(each)
Installation procedure leaflet (English / Japanese) ...1 pc.(each)
IMPORTANT SAFETY INSTRUCTIONS ................1 pc.
Code label*
1
........................................................1 pc.
*1 This label may be required for network management. Use caution not to lose this label.
The following parts are used during installation procedures.
Attachment plate .................................................1 pc.
Fixing screw for attachment plate
(M4 x 8 mm{5/16 inches}).................................. 5 pcs.
(of them, 1 for spare)
Template ......................................................... 1 sheet
Attachment for the conduit ..................................1 pc.
Cable for easy kitting
*2
.........................................1 pc.
Bit (Hex wrench,
screw size 6.35 mm {1/4 inches} T20) .................1 pc.
Grommet ........................................................... 2 pcs.
(of them, 1 for spare)
RJ45 cap .............................................................1 pc.
Rain wash coating label(with ClearSight coating model
only) ...................................................................1 pc.
*2 The cable for easy kitting is attached to the camera.
Other items that are needed (not included)
• Fixing screw
Installation method
Recommended
screw
*1
Minimum pull-out
strength
*2
: Mount the camera on a gangbox/ junction
box using the attachment plate
M4 × 16 mm
{5/8
inches} × 4 pcs.*
3
196 N {44 lbf}
: Directly mount the camera onto the
installation surface using the attachment plate
: Mount the camera onto the installation surface
using the base bracket
Mount the camera using the exclusively designed mount bracket.
Refer to the operating instructions of each bracket.
*1 Select screws according to the material of the location that the camera will be mounted to. In this case,
wood screws and nails should not be used.
*2 This value indicates the minimum pull-out strength required value per screw. For information about the
minimum pull-out strength, refer to our technical information website <Control No.: C0120>.
*3 The screw length is an example when installing the camera on a robust installation surface with a thickness
of 20 mm {25/32 inches} or more.
• Ethernet cable with RJ45 plug (category 5e or better, straight, all 4 pairs (8 pins))
• As necessary, audio input cable, audio output cable, alarm I/O cables, power supply cable
• Tools
Installation
For information about the installation procedure, refer to the provided installation procedure leaflet.
Gangbox/
Junction box
Directly mount
Base bracket
Do not place this product in the following places
• Locations where a chemical agent is used such as a swimming pool
• Locations subject to moisture or oil smoke such as a kitchen
• Locations that have a specific environment that is subject to an inflammable atmosphere or solvents
• Locations where a radiation, an X-ray, a strong radio wave or a strong magnetic field is generated
• Locations near coasts directly subjected to sea breezes, or locations subject to corrosive gases such as from
hot springs, volcanic regions, etc.
• Locations where the temperature is not within the specified range
• Locations subject to vibrations, such as on vehicles, marine vessels, or above product lines (This product is
not designed for on-vehicle use.)
• Locations subject to condensation as the result of severe changes in temperature
• Locations near rubber products (packing, rubber feet, etc.)
Screw tightening
Do not use an impact driver. Use of an impact driver may damage the screws or cause tightening excessively.
Installing in low temperature environments
This product is equipped with an internal heater unit for use in cold climates. The heater unit turns on automatically when the
temperature inside the product drops below around –15°C {5 °F}. When this product is installed and operated in low temperatures
below –20 °C {–4 °F}, it may require time to start up since the camera will wait to be warmed up internally by the internal heater
right after the power is turned on. Also, the camera may not function properly, if it is installed and operated in an environment
where the temperature is below –25 °C {–13 °F}. In such a case, wait approximately 2 hours or more until the camera is warmed
up. Then, turn on the power again. As the camera warms up, snow or frost accumulated on the dome cover will melt. However, it
may not be defrosted from the cover depending on the ambient temperature or weather condition.
About reflection of light from outside or IR light
A ghost may appear on the screen depending on the incident angle of external light.
In the case of using the IR light, installation of a camera near a wall may cause reflection of infrared rays resulting
in a part of the screen or the entire screen turning whitish.
• Refer to our support website <Control No.: C0109> for image examples and measures to take.
Take notice of humidity
Install this product when the humidity is low. If installation is performed when it is raining or in very humid
conditions, the inside may be affected by humidity, causing mist-over inside the dome cover.
Protection from lightning
When cables are used outdoors, there is a chance that they may be affected by lightning. In such a case, install
a lightning arrestor close to the camera, and make the length of the network cable between the camera and
lightning arrestor as short as possible to prevent the camera from being affected by lightning.
When noise disturbance may happen
Noise may appear in video or audio near a strong electric field from a TV or radio antenna, motors and
transformers, or a strong electric field/magnetic field from a power line (lamp line) of AC100 V or more. Conduct
the power distribution work to keep 1 m {3.28 feet} away from them or conduct the electric conduit work using
metal pipes. (Be sure to make ground connection of the metal pipes.)
Make sure to remove this product if it will no longer be used.
This product has no power switch.
When turning off the power, disconnect the power supply from the 12 V DC power supply or the PoE device.
About the battery
A battery is installed inside the camera. Do not leave the battery exposed in environments of excessive heat as a
result of sunlight or fire.
Equipment classification and power source indication label
Refer to the indication label on the bottom side of this unit for the equipment classification, power source, and other information.
About static electricity
Before installing or removing this product, be sure to touch metal objects to discharge static electricity from your body.
Open Source Software
• This product contains open source software licensed under GPL (GNU General Public License), LGPL (GNU
Lesser General Public License), etc.
• Customers can duplicate, distribute and modify the source code of the software under license of GPL and/or LGPL.
• For details concerning licensing and source code of open source software, click “Click here for OSS
information” on “Support” page of the setup menu of this product and read the displayed content.
• Please note that we shall not respond to any inquiries regarding the contents of the source code.
*1 Refer to our technical information website <Control No.: C0106> for further information about Power source
and Power consumption information.
*2
When using with the IR LED light constantly lit, the upper limit of the operating temperature range is +50 °C
{+122 °F}.
*3
257V2L
256V2L
This camera is not equipped with the function to change the audio output to the monitor output.
255V3L
255F6L
255F3L
*4 The audio output can be switched to the monitor output. Refer to the "Operating Instructions" on our support
website for descriptions of how to switch the output.
*5 Only when installation work is properly performed according to the Installation Guide and appropriate
waterproof treatment is performed.
*6 Component that has a structure on which the screws that are accessible after installation cannot be
screwed or unscrewed using an ordinary screwdriver.