PROTECTION FROM ELECTRIC SHOCK
Shut down power to the entire installation at the building’s main power distribution board and lock
out power (by removing the fuse for example) before carrying out any installation or
maintenance work.
Disconnect the fixture from AC power before removing or installing any cover or part
and when not in use.
Disconnect the fixture from AC power before removing or changing the fuse.
Always ground (earth) the fixture electrically.
Use only a source of AC power that complies with local building and electrical codes and has both
overload and ground-fault (earth-fault) protection.
Connect this fixture to AC power either using the supplied power cable or via 3- conductor cable
that is rated minimum 20 amp, hard usage. Suitable cable types include
ST, SJT, STW, SEO, SEOW and STO.
The voltage and frequency at the power outlet are the same as the voltage and frequency applied
to the power inlet. Only connect devices to the power outlet that accept this voltage & frequency.
Before using the fixture, check that all power distribution equipment and cables are in perfect
condition and rated for the current requirements of all connected devices.
Do not use the fixture if the power cable or power plug are in any way damaged, defective or wet,
or if they show signs of overheating.
PROTECTION FROM FIRE
Do not attempt to bypass thermostatic switches or fuses. Replace defective fuses with ones of
the specified type and rating only.
Provide a minimum clearance of 0.1 m (4 in.) around fans and air vents.
Do not modify the fixture
Apart from I-PIX accessories do not stick filters, masks or other materials directly onto the light.
PROTECTION FROM INJURY
Do not hang fixtures from each other. Use two OMEGA clamps per fixture or I-PIX
SINGLE or DOUBLE YOLKS when suspending.
When suspending the fixture, ensure that the structure and all hardware used can hold at least
10 times the weight of all devices suspended from them.
Use two secondary attachments (such as a safety cable) to secure each fixture.
Secondary attachments must be able to hold at least 10 times the weight of all devices
suspended from them and must be installed as described in this manual.
Check that all external covers and rigging hardware are securely fastened.
Block access below the work area and work from a stable platform whenever installing,
servicing or moving the fixture.
The LED emission presents a hazard to eyesight at a distance of 4 - 40 cm (1.6 -16 inches)
when the eye is exposed to the beam for longer than 0.25 seconds.
Do not look at LEDs from a distance of less than 40 cm (1 ft. 4 in.) without suitable
protective eye wear.
Do not look at LEDs with magnifiers or similar optical instruments that may concentrate the
light output.
BB4 USERS MANUAL -
PAGE 4
when rigging
horizontally.