background image

 

NOVASTACK

®

 35-HDN    Instruction Manual

 

Document No. 

HIM-18019

 

 

 
 

 

2

  / 

8

 

Confidential C                                                                   

弊社製コネクタ NOVASTACK 35-HDN を安全に御使用頂くことを目的とし、コネクタの挿入・抜去の手順及び注意点を 
記述致します。 

    This manual provides the insertion & withdrawal methods and cautions to handle NOVASTACK 35-HDN 

connector properly. 

 
    1.対象コネクタ名称・型番・部品名/Connector Name, Part number, Part name 
 
    1-1.Plug connector 

名称/Product Name  :  NOVASTACK 35-HDN Plug Ass'y 
型番/Part No.            :  20864-0**E-01 

 

 

   

 

 

 

 

 

 

 

 

 

 

1-2.Receptacle connector 
          名称/Product Name  :  NOVASTACK 35-HDN Receptacle Ass'y 
          型番/Part No.            :  20865-0**E-0# 

 

 

 

 

 

 

 

 

 

 

“ ** ”には各芯数番号が入ります。 

  “ ** ” part shows the number of the connector position. 

 

Shell 

Housing 

Contact 

Housing 

Contact 

Shell 

Summary of Contents for NOVASTACK 35-HDN

Page 1: ...ASTACK 35 HDN Part No PLUG 20864 0 E 01 RECEPTACLE 20865 0 E 0 Instruction Manual 2 S19630 December 12 2019 R Shioya T Yayoshi Y Shimada 1 S19307 May 20 2019 R Shioya Y Baba Y Shimada 0 S18253 April 1...

Page 2: ...tions to handle NOVASTACK 35 HDN connector properly 1 Connector Name Part number Part name 1 1 Plug connector Product Name NOVASTACK 35 HDN Plug Ass y Part No 20864 0 E 01 1 2 Receptacle connector Pro...

Page 3: ...g direction of the connectors 2 Mounting 2 1 The recommended pattern dimensions are shown in the product drawing 2 2 The recommended metal mask thickness and opening area ratio 20864 plug 20865 recept...

Page 4: ...Profile 2 5 Hand Soldering Housing 350 3 Do not apply flux when soldering by hands The flux might rise inside the connector or it may scatter The tip of the soldering iron must not touch the connecto...

Page 5: ...irection for the maintenance FPC FPC FPC 0 3 mm FPC shall be used with the stiffener to prevent the connector on the FPC side from the breakage during insertion and extraction Recommended stiffener si...

Page 6: ...here spacers will also help to prevent the damage to the connectors and to the soldered area which might have been caused by the too large printed circuit board or unbalanced shape printed circuit boa...

Page 7: ...ad which a connector can apply press the entire upper surface of the connector with the load calculated in below formula Maximum Press load number of pin 1 0N or under 4 Mating and Unmating 4 1 Always...

Page 8: ...Caution 2 10 10 At starting the insertion please keep the slant 10 or less in direction of depth By inserting with the slant more than 10 deformation of the connector will occur 3 Caution 3 Pressing...