background image

 

CABLINE

®

-VS IIF Instruction Manual

 

Document No. 

HIM-17039

 

 

 
 

 

7

  / 

11

 

Confidential C                                                                   

 

③Cover の図 13○部を基板側へ押し込み、リセプタクルコネクタの SHELL と Lock Bar をロックさせる。 

              Push two circled area of a cover down toward the PCB direction at a same time to lock receptacle 

          shell and lock bar. 
   
 
 
 
         
 
 
 
 
 
 
 
 
 

               

 

 

 

 

Push 

基板側へ押し込む 

Push the lock cover/ bar downward 

ロック状態 

Locked condition 

ロックが掛かっている事を確認 

Check the lock is in locked position 

図 13 (Fig 13.)   

Summary of Contents for 20862-030T-01

Page 1: ...HIM 17039 Confidential C I PEX Inc QKE DFFDE09 03 REV 8 CABLINE VS IIF Part No 20862 0 T 01 Instruction Manual 0 S17844 November 14 2017 Y Miyazaki T Masunaga H Ikari Rev ECN Date Prepared by Checked...

Page 2: ...VS IIF SHELL ASS Y Part No 20862 0 T 01 Receptacle connector Product Name CABLINE VS II RECEPTACLE Part No 20849 0 E 0 part shows the number of the connector position part shows the variation Please...

Page 3: ...3 please set so that the datum pin mark of Plug connector and Receptacle connector are matched 4 As shown in Fig 4 push both ends of Plug connector horizontally and confirm there is no gap Datum pin...

Page 4: ...n in Fig 3 Cover Cover Rece Shell Do not close a cover if slant mating was confirmed Interference of a cover and a receptacle shell may deform the connector 2 Caution 2 Shell Please insert the connect...

Page 5: ...than 5 deformation of the connector will occur 4 Caution 4 Lock Bar ass y Cover FPC FPC If cover is opened up more than its stopped position cover edge may damage the FPC 5 Caution 5 8 8 At starting t...

Page 6: ...sertion to avoid deformation or any connector damage 8 Caution 8 Please do not apply force toward the PCB side to the plug connector in insertion PCB will be damaged like below and it may cause the di...

Page 7: ...1 Confidential C Cover 13 SHELL Lock Bar Push two circled area of a cover down toward the PCB direction at a same time to lock receptacle shell and lock bar Push Push the lock cover bar downward Locke...

Page 8: ...release the lock Rotate the cover bar as shown on the bottom right figure 9 Caution 9 Lock bar ass y Lock bar ass y When releasing the lock do not lift by the center of the lock bar ass y There are p...

Page 9: ...14 hold both ends of the Plug connector and withdrawal it parallel 10 Caution 10 5 5 Please keep withdrawal slant 5 or less in horizontal direction By withdrawing with the slant more than 5 deformati...

Page 10: ...ssibilities to cause the Lock bar ass y and connector deformation 12 Caution 12 Please do not apply force toward the PCB side to the plug connector in withdrawal PCB will be damaged like below and it...

Page 11: ...connector to the vertical direction It may cause the receptacle connector s deformation FPC FPC In handling the FPC please pay attention not to apply excessive force to the connector or the FPC It may...

Reviews: