background image

 

MINIFLEX 2-BF LK TYPE Instruction Manual

 

Document No. 

HIM-17036

 

 

 
 

 

12

  / 

13

 

Confidential C                                                                   

6. FPC の抜去について/ To withdraw FPC   

アクチュエータ解除状態で真っ直ぐ FPC を抜去して下さい。 
Please withdraw FPC straight in the connector with actuator release condition. 
 
 

 
 
 
 

 

図 21. FPC の抜去方法    / Fig.21 To withdraw FPC   

≪注意/Caution≫

 

(1)  アクチュエータクローズ状態で FPC を抜去しないで下さい。FPC を破損させる原因となります。 

Please refrain from withdrawing FPC with actuator close condition. It may cause deformation of FPC.   

   
 
 
 
 
 

 

図 22. FPC の抜去方法  (NG) / Fig.22 To withdraw FPC (NG)

 

 

 
 

 
 
 
 

 
 

 
 
 
 
 
 

 

 

図 23. (a)アクチュエータクローズ状態で抜去した場合  (b)正常抜去した場合 

Fig.23 In case

 

withdrawing FPC with (a) actuator close condition or (b) actuator release condition   

 
※図 23 の様に FPC がダメージを受けると、FPC 保持力が低下致しますので新しい FPC に交換してください。 

If FPC receives damage like Fig.23, FPC retention force will be down, please exchange to new FPC 

NG 

OK 

ダメージ 

Damage 

ダメージ無し 

No damage 

NG 

Summary of Contents for 20817-120E-01

Page 1: ...8 MINIFLEX 2 BF LK TYPE Part No 20817 E 01 Instruction Manual 2 S19622 October 2 2019 R Morita T Masunaga H Ikari 1 S18616 September 27 2018 Y Miyazaki T Masunaga H Ikari 0 S18223 April 2 2018 A Koyan...

Page 2: ...ndle our FPC connector MINIFLEX 2 BFLK TYPE properly and safely Connector Product Name MINIFLEX 2 BF LK TYPE Part No 20817 E 01 part shows the number of the connector position Names of each part of th...

Page 3: ...ect to the contact pressure and the reliability will not be damaged However there is the possibility that the insertion force rises in inserting FPC because the gap of contacts became narrowed Therefo...

Page 4: ...the connector Please confirm FPC is inserted into the end of mating part fully 4 FPC OK Fig 4 FPC insertion OK Caution 5 FPC If it becomes the short insertion and oblique insertion of FPC as shown in...

Page 5: ...The check of FPC insertion becomes easy by preparing the wing in FPC and preparing the silk print in board 6 FPC Fig 6 The check of FPC insertion Reference 7 FPC OK Fig 7 FPC insertion OK NG Short ins...

Page 6: ...push against housing both ends at 5N or more Housing is damaged 9 FPC NG Fig 9 FPC insertion NG FPC FPC Please do not press FPC near a connector Contact gives damage to FPC and contact is damaged It b...

Page 7: ...actuator to the arrowed direction horizontally with finger cushion from the FPC inserting direction 11 OK Fig 11 To lock actuator OK Caution Please do not press an actuator from a top and lock actuato...

Page 8: ...fidential C Please do not operate side of an actuator Actuator is damaged or it becomes imperfect lock 13 NG Fig 13 To lock actuator NG Please do not press contact on top by finger nail etc after a lo...

Page 9: ...ctuator after a lock actuator Connector and FPC are damaged It becomes the electrical connection NG 15 NG Fig 15 To lock actuator NG Please do not operate it using a sharp tool For example tweezers Co...

Page 10: ...ot press to the direction of FPC mating side Actuator and contacts are damaged 17 NG Fig 17 To release actuator NG Please do not operate side of an actuator Actuator is damaged 18 NG Fig 18 To release...

Page 11: ...from the end of FPC stiffener 19 FPC OK Fig 19 Flexion of FPC OK Caution FPC FPC FPC Please avoid applying excessive stress to the FPC connector exit part FPC stiffener with FPC inserted Housing and c...

Page 12: ...withdraw FPC Caution 1 FPC FPC Please refrain from withdrawing FPC with actuator close condition It may cause deformation of FPC 22 FPC NG Fig 22 To withdraw FPC NG 23 a b Fig 23 In case withdrawing...

Page 13: ...l C 7 Regarding board warp after mounting 90mm PCB 0 5mm JEITA ED 4702C Be careful that warp of 90mm width PCB is 0 5mm or less If excessive warp is applied Connector is damaged Reference standard JEI...