background image

 

CABLINE-VSF CONN. Instruction Manual

 

Document No. 

HIM-13010 

 

 
 

 

6

  / 

12

 

Confidential C                                                                                                                                                                                                   

 

注意事項

  / Cautions. 

片側ずつ押すと、隙間が発生する恐れが有ります。(図

9

 

 

When you push one end it might cause half mating. 

Fig.9

 

 

 

 

 

 

 

 

 

 

9

Fig.9

 

 

10

のように挿入時に

LOCK BAR

を押しながら挿入すると、

LOCK BAR

が変形したり、回転軸がコネクタ

 

から抜ける恐れがありますので、行わないでください。

 

When mating, in case you mate the connector pushing LOCK BAR as shown in Fig.10, there are possibilities to cause LOCK BAR 

deformation or the rotation axis dropping out from the connector. Please don’t push LOCK BAR. 

 

 

 

                     

 

 

 

 

 

 

 

 

 

 

10

Fig.10

 

 

 

 

隙間発生

  NG

状態

 

There is gap. NG 

片側挿入

Push the one side. 

片側挿入

Push the one side. 

LOCK BAR

をコネクタの挿入に使用しないでください。

 

Please don’t use LOCK BAR for insertion of connector. 

回転軸

 

Rotation axis.

 

Summary of Contents for 20455-030E-02

Page 1: ...3 REV 8 CABLINE VSF CONN Part No PLUG 20645 0 T 01 3049 0 1 RECEPTACLE 20455 0 E Instruction Manual 2 S14534 December 22 2014 H A E K 1 S14257 June 30 2014 H I E K 0 S13474 December 10 2013 H Aoki J T...

Page 2: ...E VSF PLUG Part No 20645 0 T 01 SHELL ASS Y With LOCK BAR 3049 0 1 SHELL Without LOCK BAR Fig 1 SHELLASS Y With LOCK BAR Fig 2 SHELL Without LOCK BAR FPC assembly state FPC assembly state PCB side con...

Page 3: ...matched 3 Fig 3 2 How to mate 4 FPC As shown in Fig 4 push FPC horizontally until it is locked 4 Fig 4 SHELL LOCK BAR For the connector SHELL Without LOCK BAR FPC Insert FPC to the connector horizont...

Page 4: ...NE VSF CONN Instruction Manual Document No HIM 13010 4 12 Confidential C Cautions 5 When you push one end it might cause half mating Fig 5 5 Fig 5 NG There is gap NG 1 Push the one side 2 Push the one...

Page 5: ...er there is space between mating confirmation surfaces 6 Fig 6 LOCK BAR SHELL After mated push LOCK BAR to the PCB side and lock it to SHELL of the PCB side connector 7 Fig 7 Contents of confirmation...

Page 6: ...OCK BAR When mating in case you mate the connector pushing LOCK BAR as shown in Fig 10 there are possibilities to cause LOCK BAR deformation or the rotation axis dropping out from the connector Please...

Page 7: ...ow When you push only one side at the temporary insert condition maximum slanted degree have to be less than 5 Deformation of the connector doesn t occur if insertion angle is kept less than 5 degree...

Page 8: ...ed un mating might cause deformations of FPC or damage on FPC pattern OK horizontal un mating OK condition 11 Fig 11 NG Slanted un mating NG 5 To use this connector safely please withdraw plug up to a...

Page 9: ...described in Fig 11 Caution Except for part if you pull up the LOCK BAR towards direction LOCK BAR would have deformation or the connector would have damage Also if you use Insulated part of LOCK BAR...

Page 10: ...13 As Fig 14 please make un mating by pulling the horizontal part in parallel to PCB Caution Except for part if you pull up the LOCK BAR towards direction LOCK BAR would have deformation or the connec...

Page 11: ...C is pulled to the vertical direction or slanted direction SHELL of the receptacle connector can deform or FPC might pull out from plug Please don t pull FPC vertically or with slanted angle LOCK BAR...

Page 12: ...too much pulling force to FPC Please refrain from applying pulling force or repeated bending force to the FPC assembly part of a plug connector 15 Fig 15 16 FPC Please refrain from applying cable ret...